SimCortex: Collision-free Simultaneous Cortical Surfaces Reconstruction
Kaveh Moradkhani, R Jarrett Rushmore, Sylvain Bouix · 2025
Read SimCortex: Collision-free Simultaneous Cortical Surfaces Reconstruction by Kaveh Moradkhani, R Jarrett Rushmore, Sylvain Bouix (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-06955.txt.
Introduction
Rebuilding the brain's folded surface from a scan sounds simple. Then the sheets overlap, pierce themselves, or tear. Kaveh Moradkhani and co-authors present a learning system built to keep them clean. SimCortex reconstructs all four cortical surfaces, inner and outer on both sides, in one pass. It starts from a nine-class tissue map of a standard MRI scan.
From that map the system grows subject-specific starting meshes that cannot collide. It then warps them smoothly through deformations that preserve topology by design. Tests on standard datasets show far fewer overlaps and self-intersections than current methods. Geometric accuracy still matches the best. For brain studies that measure thickness or map function onto the surface, clean geometry separates trustworthy numbers from artifacts.
Catalog record
| CREATOR | Kaveh Moradkhani, R Jarrett Rushmore, Sylvain Bouix |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-06955
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
SimCortex: Collision-free Simultaneous Cortical Surfaces Reconstruction Kaveh Moradkhani, R Jarrett Rushmore, Sylvain Bouix Abstract Accurate cortical surface reconstruction from magnetic resonance imaging (MRI) data is crucial for reliable neuroanatomical analyses. Current methods have to contend with complex cortical geometries, strict topological requirements, and often produce surfaces with overlaps, self-intersections, and topological defects. To overcome these shortcomings, we introduce SimCortex, a deep learning framework that simultaneously reconstructs all brain surfaces (left/right white-matter and pial) from T1-weighted(T1w) MRI volumes while preserving topological properties. Our method first segments the T1w image into a nine-class tissue label map. From these segmentations, we generate subject-specific, collision-free initial surface meshes. These surfaces serve as precise initializations for subsequent multiscale diffeomorphic deformations. Employing stationary velocity fields (SVFs) integrated via scaling-and-squaring, our approach ensures smooth, topology-preserving transformations with significantly reduced surface collisions and self-intersections. Evaluations on standard datasets demonstrate that SimCortex dramatically reduces surface overlaps and self-intersections, surpassing current methods while maintaining state-of-the-art geometric accuracy. 1 Introduction Accurate cortical surface reconstruction from MRI data enables precise measurement of key morphometric features—cortical thickness, curvature, and sulcal depth—that are invaluable for neuroimaging analyses. However, the inherent complexity of cortical geometry, compounded by partial volume effects (PVE) [ 1 ] and stringent spherical topology [ 5 ] requirements, poses substantial challenges to achieving anatomically and topologically accurate surface reconstructions. Traditional methods, such as FreeSurfer [ 7 ] , BrainSuite [ 17 ] , and CIVET [ 13 ] , rely on voxel-based segmentation pipelines followed by explicit mesh-based modeling. These methods are computationally intensive and require multiple hours per subject, limiting their scalability in large-scale neuroimaging studies or time-sensitive applications [ 11 ] [ 3 ] . To address computational efficiency, recent deep learning approaches have drastically reduced surface estimation runtime while achieving comparable accuracy. Implicit surface reconstruction methods, such as DeepCSR [ 5 ] have been proposed to overcome voxel discretization limitations by representing cortical surfaces as signed distance functions followed by mesh extraction via Marching Cubes. Although these implicit methods can represent surfaces at arbitrary resolutions, in practice they do not achieve high anatomical accuracy [ 10 ] [ 4 ] . Explicit mesh-based deformation methods directly deform an initial mesh template toward the target cortical surfaces. CorticalFlow [ 10 ] and its improved variant, CorticalFlow++ [ 16 ] , leverage diffeomorphic transformations to ensure topological integrity and reduce mesh artifacts. Similarly, CortexODE [ 11 ] employs neural ordinary differential equations (ODEs) to model continuous mesh deformations, offering theoretical guarantees of smooth and diffeomorphic transformations aimed at reducing self-intersections. However, these methods typically reconstruct cortical surfaces independently, lacking explicit modeling of the geometric relationships between surfaces, which can lead to intersections between surfaces. Vox2Cortex [ 3 ] and V2C-Flow [ 4 ] combine convolutional and graph neural networks, guided by curvature-weighted loss functions, to achieve accurate reconstruction with anatomically meaningful vertex correspondences. While, Vox2Cortex can estimate all surfaces together, it does not offer topological guarantees. Hybrid methods, such as Hybrid-CSR [ 18 ] , merge explicit and implicit techniques, improving geometric detail but increasing computational complexity, and they also do not ensure that topological properties are preserved. Closest to our work, Zheng et al. [ 20 ] propose a coupled reconstruction framework that jointly optimizes white matter, pial, and midthickness surfaces for each hemisphere independently using diffeomorphic mesh deformation, ensuring spherical topology. However, their method processes the two hemispheres independently, and thus does not consider inter-hemispheric spatial relationships or collisions between left and right cortical surfaces. Furthermore, the iterative optimization of three diffeomorphic flows per hemisphere may increase computational demands for large datasets. To address these gaps, we introduce SimCortex which simultaneously reconstructs white matter and pial surfaces for both hemispheres using segmentation-based initialization and multiscale diffeomorphic deformations. Unlike methods that process each surface independently or sequentially, SimCortex jointly estimates the four cortical surfaces—left and right white and pial surfaces—ensuring proper geometric relationships between these surfaces. Subject-specific topologically accurate initial meshes are estimated via voxel segmentation and a topologically aware mesh generation pipeline. Multiscale diffeomorphic deformations are then estimated via deep learning to refine these meshes smoothly, preventing self-intersections and topological errors. Combining segmentation-driven initialization with diffeomorphic shape modeling, SimCortex delivers efficient reconstructions with state-of-the-art accuracy while achieving significantly fewer surface collisions and self-intersections. 2 Method The SimCortex pipeline, illustrated in Figure 1 , reconstructs white matter and pial surfaces for both hemispheres simultaneously from T1w MRI scans, prioritizing topological correctness and minimal surface collisions. The workflow comprises three main stages: preprocessing, segmentation-based initialization, and multiscale diffeomorphic deformation. Figure 1 : Overview of the SimCortex pipeline. 2.1 Data Preprocessing Inspired by Vox2Cortex [ 3 ] , SimCortex aligns T1w MRI volumes, segments labels, and registers cortical surface meshes to MNI152 space using affine transformations. 2.2 Multi-Class Segmentation and Initial Surface Generation SimCortex’s pipeline for segmentation and initial surface generation, shown in Figure 2 , processes MNI152-aligned T1w MRI volumes to create topologically correct, collision-free template meshes. A 3D U-Net generates a nine-class map (background, left/right white matter, cortex, amygdala-hippocampus complex and lateral ventricle). Trained on FreeSurfer ground truth with cross-entropy loss, it achieves high Dice scores ( \approx 0.9 ). For each subject-specific template surface (e.g., left pial), we build a binary mask combining labels for robust region definition. The pial label is the union of white matter, cortex, and ventricles, and the white label is the union of white matter and ventricles. From each mask’s largest component, we compute a signed-distance field (SDF), smoothed by a Gaussian filter ( \sigma=1 mm) and further process it with a fast-marching algorithm that ensures spherical topology [ 2 ] . We interpolate at sub-voxel levels to define continuous surfaces at iso-values \lambda , e.g., S^{\lambda}=\{x\mid\mathcal{U}(x)=\lambda\} . To extract the cortical surfaces, we define each surface as an isosurface at a specific threshold \lambda of the computed signed distance fields (SDF). For pial surfaces, the initial isosurface extraction threshold is set at \lambda_{\text{pial}}=-0.1 . We use Marching Cubes to obtain a mesh, and subsequently apply Laplacian smoothing. After extraction, we perform collision checks (e.g., vertex intersections) to ensure the resulting pial mesh does not intersect the contralateral mesh. If collisions are detected, the threshold \lambda_{\text{pial}} is incrementally adjusted in steps of -0.05 until no collisions occur. For white matter surfaces, we begin the extraction with an initial threshold slightly lower than the final pial threshold \lambda_{\text{WM}}=\lambda_{\text{pial}}-0.1 . Collision checks between the resulting white mesh and all other surfaces (pial and contralateral pial and white) are conducted. If collisions occur, the white matter threshold is iteratively adjusted in increments of -0.1 until a collision-free configuration is obtained. This yields four non-overlapping, genus 0 subject-specific template meshes in MNI152 space, which serve as input for the final joint surface reconstruction network. Figure 2 : Workflow for segmentation-driven cortical surface initialization. From MNI152-aligned T1w MRI, a 3D U-Net segments tissues, masks are converted to smoothed SDFs, topologically corrected, and extracted as collision-free meshes for deformation. 2.3 Cortical Surface Reconstruction The final cortical surface reconstruction step is adapted from [ 12 ] . Our deep learning framework, illustrated in Figure 3 , employs a sequence of diffeomorphic transformations applied simultaneously to the four subject-specific cortical meshes (left/right white matter and pial surfaces). Importantly, these transformations operate