Read Optimisation of Electrolyser Operation: Integrating External Heat by Matthias Derez, Alexander Hoogsteyn, Erik Delarue (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-06796.txt.
Introduction
Matthias Derez, Alexander Hoogsteyn, and Erik Delarue study how to run electrolysers more cheaply in a 2025 energy paper. These machines split water to make hydrogen, a fuel that can be made without carbon output. Feeding in outside heat can cut the power the machine draws, but heat supply and start-up costs complicate daily planning.
The authors build a planning model that treats start-up costs from within and adds direct heat input, using a simplified form of the underlying chemistry equations. They then weigh low-grade and high-grade heat for two machine types: solid oxide and membrane-based designs. The goal is to show when outside heat lifts both efficiency and profit.
Catalog record
| CREATOR | Matthias Derez, Alexander Hoogsteyn, Erik Delarue |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 36 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-06796
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Optimisation of Electrolyser Operation: Integrating External Heat Matthias Derez, Alexander Hoogsteyn, Erik Delarue Abstract Integrating external heat into electrolysers can reduce the electrical power demand for carbon-neutral hydrogen production. Efficient operation requires detailed models that incorporate heat availability and its effect on startup costs. This paper advances existing operational models by endogenously modelling startup costs and direct heat integration, based on a piecewise linear approximation of the electrochemical equations. We analyse the impact of low- and high-temperature heat integration on the efficiency and profitability of hydrogen production for solid oxide and proton exchange membrane (PEM) electrolysis technologies. Our case study demonstrates that heat integration can significantly enhance the profitability of solid oxide electrolysis, increasing average daily profits by up to 23.3%. For PEM electrolysis, the impact is more modest, with profit gains of 1.9–2.7%. Despite this, the break-even hydrogen price for solid oxide electrolysis remains high at 5.5 EUR/kg, given an investment cost of 2300 EUR/kW. PEM electrolysis achieves breakeven at more competitive hydrogen prices of 3.5–4.5 EUR/kg, depending on lifetime assumptions and an investment cost of 900 EUR/kW. I Introduction To reduce the amount of renewable electricity required for green hydrogen production, heat can be integrated into the electrolysis process. Depending on the technology heat can be added either directly to provide a share of the required enthalpy change to carry out the electrolysis reaction or indirectly in other processes in the balance of plant. Both approaches reduce the required amount of electrical energy and improve the profitability. Efficiency improvements can be achieved using a variety of low carbon energy sources: geothermal energy [ 1 ] , biomass [ 2 ] or nuclear energy [ 3 , 4 ] , among others. Secondly, electrolysers can increase profitability by exploiting their flexibility by adapting their hydrogen production to fluctuating electricity prices and participate in ancillary services markets [ 5 ] . However, the electrical efficiency of an electrolyser depends on the operating temperature and current density. These operating parameters can change throughout the production period, introducing variations in electrical efficiency that are often not considered [ 6 ] . Advanced operational models, capable of capturing flexibility and variable efficiency, are necessary to accurately estimate the profits of an electrolyser [ 7 ] . To accurately represent dynamic electrolyser operation, the effect of both the temperature and current density on efficiency must be considered. This can be done by incorporating the governing electrochemical Eqs., where the chemical processes that occur and the accompanying losses are described [ 8 , 9 , 10 ] . Alternatively, empirical electrochemical models can be used that approximate the relation [ 11 ] . Such empirical models are available only for alkaline electrolysers but are nonetheless used to approximate the behaviour of proton exchange membrane (PEM) and solid oxide electrolyser (SOE) [ 7 , 12 , 13 ] . In this paper, operational models are developed which incorporate the original electrochemical Eqs. that relate the power consumed by the electrolyser to the operating temperature and current. To the author’s knowledge, a piecewise linearisation of the original electrochemical model Eqs. has not been carried out in the literature. [ 13 ] have approximated the empirical model by Ulleberg using a single tangent plane to the power curve at nominal power. [ 7 ] have carried out a two-dimensional piecewise linearisation of [ 11 ] , where the temperature dependency is neglected, limiting the accuracy of the model to discuss the effect of heat addition. Furthermore, the models are adapted to allow for external heat to be used in the electrolysis process. For each electrolyser type, the model is modified to make use of heat as applicable. The modelling contribution of this paper is therefore twofold; the startup behaviour is modelled more accurately, and heat addition is integrated into the models. The models are applied to a case study to discuss the results and implications of the improvements made. II External heat integration External heat integration in electrolysis technologies—such as Alkaline, Proton Exchange Membrane (PEM), and Solid Oxide Electrolysers (SOE)—can significantly enhance their performance and efficiency. SOEs, in particular, benefit greatly from external heat due to their high operating temperatures (800–1000 \degree C), which align well with the availability of high-temperature heat sources [ 14 ] . The integration of heat in SOEs can reduce the overall electrical energy requirement by supplying part of the necessary thermal energy directly through external heat sources or regeneration processes. This approach allows the electrolysis process to operate below the thermoneutral voltage while keeping the operating temperature constant, reducing the electrical input needed for water electrolysis. Various auxillary processes, such as preheating during cold start and heating during standby, are able to use external heat. An overview of the heat integration possibilities is provided in Table I . TABLE I : Use of low- and high-temperature heat for different electrolysers PEM (20-100 \degree C ) & Alkaline (40-90 \degree C ) SOE (800-1000 \degree C ) Low-T heat (280-325 \degree C ) • Heating and evaporating inlet water • Heating electrolyser during cold start, in combination with an electrical heater High-T heat (750-1000 \degree C ) • Heating inlet water • Keeping temperature constant in standby • Heating electrolyser during cold start • Heating and evaporating inlet water • Heating steam from pinch point to operating temperature • Keeping temperature constant in standby • Heating electrolyser during cold start • Heating sweep gases to supply heat directly to the electrolyser [ 14 ] explored the effects of using external heat sources in the SOE operating range, highlighting that high-temperature heat can be employed to preheat inlet water and superheat steam using regenerative heat exchangers. This configuration obtains a system efficiency improvement of 18% by minimizing the amount of electrical energy required to achieve the high operational temperatures of the SOE. [ 3 ] evaluates the efficiency of high-temperature steam electrolytic systems coupled with various types of nuclear reactors. It specifically examines how heat from different nuclear reactor designs can be used to generate the steam needed for the electrolysis process, aiming to optimize the overall system performance. In contrast, the Alkaline and PEM electrolysers operate at significantly lower temperatures (20–100 \degree C for PEM and 40–90 \degree C for Alkaline), and cannot directly use external heat to drive the electrolysis reaction due to their inherently exothermal operating regimes. However, heat can still be beneficial for auxillary processes, such as preheating the inlet water or maintaining the electrolyser temperature during standby modes, thereby reducing the need for electrical heating and enhancing overall system efficiency. III Operational models III-A Linearisation of electrochemical models A piecewise linearisation is applied to the power curves of the PEM and SOE electrolyser. An example of such a nonconvex power curve of the SOE is shown in Figure 1 together with its division into multiple segments. Each segment approximates the power values in its own segment by minimising the square of linearisation error. (a) (b) Fig. 1 : (a) Power consumed per cell by a SOE as a function of temperature and current density based on the underlying electrochemical effects described in Appendix A and (b) its linearization with four segments The least squares method is used to determine