Subcycle phase matching effects in short attosecond pulse trains

N Ouahioune, R Martín-Hernández, D Hoff, PK Maroju, C Guo, R Weissenbilder, S Mikaelsson, A L’Huillier, CL Arnold, M Gisselbrecht · 2025

Read Subcycle phase matching effects in short attosecond pulse trains by N Ouahioune, R Martín-Hernández, D Hoff, PK Maroju, C Guo, R Weissenbilder, S Mikaelsson, A L’Huillier, CL Arnold, M Gisselbrecht (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-06386.txt.

Introduction

Ouahioune and co-authors probe how sub-cycle phase match shapes trains of ultra-short light pulses. The work dates to 2025. The pulses come from a gas struck by strong laser light. Their use to track fast charge moves needs sharp reads on tone and time form.

The team made trains of two to three pulses and read them with a two-tone light test. When the laser's phase tag turned by a set step, high tones held more pulses than low ones. Sims tied that odd shape to how tone match shifts in time through the burst. The test let them pull that shift out of the reads.

Catalog record

CREATORN Ouahioune, R Martín-Hernández, D Hoff, PK Maroju, C Guo, R Weissenbilder, S Mikaelsson, A L’Huillier, CL Arnold, M Gisselbrecht
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE20 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2507-06386

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Subcycle phase matching effects in short attosecond pulse trains N Ouahioune, R Martín-Hernández, D Hoff, PK Maroju, C Guo, R Weissenbilder, S Mikaelsson, A L’Huillier, CL Arnold, M Gisselbrecht Abstract High-order harmonic generation (HHG) in gases driven by intense laser fields has become a cornerstone technique for producing attosecond pulses and probing ultrafast electronic motion in matter. By manipulating the microscopic and macroscopic dynamics involved in HHG, it is possible to tailor the temporal and spectral properties of attosecond light pulses. In this work, we control the carrier-to-envelope phase (CEP) of ultrashort femtosecond laser pulses to generate short trains of attosecond pulses that we characterize using two-color laser-assisted photoionization. We observe strong and unexpected variations of the photoelectron spectra as a function of the photoelectron kinetic energy as we change the CEP of the driving pulses. To interpret our results, we carried out HHG simulations that include microscopic and macroscopic effects. We find that the time-dependent phase-matching of the harmonics and the temporal chirp of the attosecond pulses play a major role in our observation, opening new perspectives for temporally resolving and controlling the HHG process. 1 Introduction High-order Harmonic Generation of an intense laser in gas targets has enabled the production of short pulses of light at the attosecond time scale in the extreme-ultraviolet (XUV) range [ 1 ] . This process arises from two coexisting physical phenomena: the highly non-linear interaction of the intense laser with an isolated atom (or molecule) - a microscopic phenomenon known as single-atom response [ 2 , 3 , 4 ] , and the in-phase propagation of the generated XUV radiation and the driving laser field - a macroscopic phenomenon known as phase matching [ 5 , 6 , 7 ] . The latter is central in determining the efficiency, coherence and spatiotemporal structure of the XUV emission. Consequently, considerable effort has been devoted to manipulating phase-matching conditions to control the properties of attosecond light sources (flux, conversion efficiency, etc… [ 8 , 9 ] ) including the generation of single attosecond pulses. However, insight into the ultrafast temporal evolution of phase-matching has so far remained primarily theoretical [ 10 , 11 ] . Here, we identify experimental conditions that provide access to the temporal build-up of the phase-matching in each optical cycle using a few-cycle driver laser. Laser-assisted photoionization schemes such as Streaking [ 12 , 13 ] and RABBIT (Reconstruction of Attosecond Beatings by Interference of Two-photon transitions) [ 14 ] are commonly used to characterize the temporal properties of isolated attosecond pulses and attosecond pulse trains (APTs). In RABBIT, an interferometric technique, multiple coherent broadband electron wavepackets created by the XUV harmonic comb interact with an near-infrared (NIR) probe field. The interaction results in additional peaks called sidebands between each pair of consecutive harmonics formed due to the absorption/emission of additional NIR photons. By scanning the delay between the XUV and the NIR, it is possible to extract the spectral (and thus temporal) properties of the XUV and probe fields [ 15 ] . In this work, we study laser-assisted ionization of helium atoms using an attosecond pulse train generated by few-cycle laser pulses in a gas of argon atoms. Due to the short laser duration ( \leq 6 fs), the APTs contain a few attosecond pulses [ 16 ] and their number depends on the CEP of the driving laser. For certain CEP values, the photoelectron spectra exhibit features that cannot be explained by the structure of the APTs predicted by the single-atom response alone. Supported by complete 3D simulation and a 1D-model, we gain insights into the time-dependent build-up of HHG in the nonlinear medium, and show that laser-assisted photoionization spectra provide a fingerprint of the generated APTs in the time and frequency domain. 2 Methods Figure 1 : (A) Schematic of the experimental setup. Laser pulses from a Ti:Sapphire oscillator are amplified using two nonlinear optical parametric amplification (NOPA) stages. The relative CEP of the output pulses is controlled shot-to-shot through the feedback of a stereo Above-Threshold-Ionization (SATI) device to a wedge pair in the oscillator [ 17 ] . The CEP-controlled pulses are separated into a probe arm and a variably delayed pump arm by a beam splitter (BS). Short attosecond pulse trains are produced by the pump using HHG and recombined with the probe before being focused into the sensitive region of a 3D electron spectrometer. (B) The controllable relative CEP \Delta\varphi_{\mathrm{CEP}} of the \leq 6 fs laser pulses. (C) Momentum projected along p_{x} and p_{z} of the photoemitted electrons. The electrons can be distinguished between those emitted with p_{z}>0 (”Up”) and those emitted with p_{z}<0 (”Down”), where z is the axis along the detector and of the polarization of the light. BS: Beam splitter; SATI: Stero-ATI; SHG: Second harmonic generation; AF: Aluminium filter; RM: Recombination mirror. MCP: Micro-channel plate. The experiment, shown in Figure 1 , was performed using an optical parametric chirped pulse amplification (OPCPA) system, providing sub-6 fs long pulses at a central wavelength of 850 nm with up to 10 \mathrm{\mu} J pulse energy at a repetition rate of 200 kHz [ 18 ] . A stereo-ATI (SATI) setup installed in the beam path stabilized the CEP of the pulses on a shot-to-shot basis, providing a stability of around 160 mrad ( \sim 10 ∘ ) [ 17 ] . Furthermore, the CEP was controlled by a wedge pair in the oscillator (not shown in the schematic). The laser beam was then split into a pump and a probe arm by a beamsplitter (BS). In the pump arm, the beam was tightly focused into an argon gas jet to generate a comb of phase-locked odd-order harmonics. The low-order harmonics, below \sim 15 eV, and the generating field were filtered out with an aluminum foil (AF) of 200 nm. The pump was recombined with the probe using a holey mirror (RM). The delay \tau between the XUV and the probe arm can be controlled using a delay stage in the pump arm. Once recombined, both fields were focused by a toroidal mirror into a helium gas jet; the probe intensity was estimated to be \sim 10^{11} W/cm 2 . A reaction microscope was used to measure the three-dimensional momentum of the photoelectrons created by the absorption of the XUV-only or the XUV+NIR radiation. In our experiments, the delay between the XUV light and the NIR probe was scanned for different CEP settings. Changing the CEP allowed us to vary the number of pulses in the train, typically between two and four [ 16 ] . 3 Results and Discussion Figure 2 A and B presents photoelectron spectra as a function of the delay for two different CEP values separated by 90 ∘ . In the figure, only electrons emitted in a solid angle of +2\pi sr (”up”) along the polarization axis of both XUV and NIR fields are shown (see Figure 1 ) [ 16 ] . At large delays, when the fields do not overlap, the photoelectron peaks are separated by a kinetic energy of 2\hbar\omega ( \hbar is the reduced Planck constant and \omega is the laser frequency) due to single-photon ionization by the comb of harmonics. At small delays,

Read the complete text