Design and Numerical Simulation of a SARA-Based RF Accelerator Using the TE 112 \mathrm{TE}_{112} Mode
Tomás A. Carreño, Jesús E. López, Yerson F. Barragan, Carlos J. Páez-González · 2025
Read Design and Numerical Simulation of a SARA-Based RF Accelerator Using the TE 112 \mathrm{TE}_{112} Mode by Tomás A. Carreño, Jesús E. López, Yerson F. Barragan, Carlos J. Páez-González (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-05436.txt.
Introduction
Tomas Carreno and co-authors wrote a 2025 paper on a compact electron accelerator design based on a method called SARA. It uses a microwave cavity plus a shaped magnetic field to keep electrons in step with the wave. Such compact machines could serve as X-ray sources.
They model the cavity fields, the coil field, and electron paths in a standard physics package. The design lifts electrons close to the target energy with a modest microwave source. The cavity stores energy well, which is a plus, but its sharp tuning demands tight frequency control. The authors give tuned design values for a build. Uses span medical imaging, security scans, and materials checks.
Catalog record
| CREATOR | Tomás A. Carreño, Jesús E. López, Yerson F. Barragan, Carlos J. Páez-González |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 37 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-05436
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Design and Numerical Simulation of a SARA-Based RF Accelerator Using the TE 112 \mathrm{TE}_{112} Mode Tomás A. Carreño, Jesús E. López, Yerson F. Barragan, Carlos J. Páez-González Abstract Charged particle accelerators play a pivotal role in scientific research, industry, and medical applications. Among them, radiofrequency (RF) accelerators offer a promising approach for achieving high-energy particle acceleration in compact systems. This study presents the design and numerical simulation of a microwave-driven electron accelerator based on the Spatial Autoresonant Acceleration (SARA) mechanism. The proposed system consists of a cylindrical resonant cavity excited in the TE 112 mode, influenced by a tailored magnetostatic field generated by a set of external coils. The electromagnetic field distribution, magnetostatic configuration, and electron dynamics were simulated using COMSOL Multiphysics. The results validate the feasibility of accelerating electrons to energies close to 200 keV with a 1 kW microwave source, demonstrating their capability for X-ray generation through Bremsstrahlung radiation. Additionally, the study provides optimized design parameters for practical implementation. The high-quality factor ( Q ∼ 25000 ) (Q\sim 25000) of the resonant cavity ensures efficient energy storage but necessitates precise frequency control to maintain resonance conditions. The findings underscore the potential of SARA-based accelerators for compact X-ray sources, with applications in medical imaging, security screening, and materials analysis. 1 Introduction Charged particle accelerators have been indispensable tools across various fields, ranging from fundamental physics to industrial and medical applications. These devices have played a crucial role in groundbreaking discoveries, such as the identification of quarks in the 1970s and the observation of the Higgs boson at the Large Hadron Collider (LHC) in 2012 [ 1 , 2 ] . Such advancements have significantly deepened our understanding of the fundamental structure of matter and the interactions governing the universe. Beyond fundamental research, accelerators are widely used in industrial applications, including material sterilization and coating, radioisotope production for nuclear energy, and medical technologies such as cancer radiotherapy and X-ray imaging [ 3 , 4 , 5 , 6 ] . Given the broad relevance of these devices, research efforts have primarily focused on two major challenges: (i) Achieving higher particle energies to support fundamental physics investigations. (ii) Reducing construction costs to facilitate broader practical applications, particularly in the healthcare sector. In particular, compact and portable accelerators for X-ray generation are of great interest, as they would enable diagnostics in remote locations and emergency scenarios. While conventional acceleration schemes—such as linear accelerators (LINACs), cyclotrons, and synchrotrons—dominate the field, alternative approaches are being explored to address these challenges [ 7 , 8 ] . One such alternative is electron cyclotron autoresonance acceleration, initially proposed by A. Kolomenskii and A. Levedev in 1962 and independently by V. Davydovskii in 1963 [ 9 , 10 ] . This mechanism exploits the resonant interaction between an electron and an electromagnetic wave in the presence of an external static magnetic field. ECR acceleration enables electrons to reach X-ray-generating energies over short distances, sparking numerous theoretical and experimental studies aimed at optimizing the resonance conditions [ 11 , 12 , 13 , 14 ] . Building upon this concept, K. S. Golovanivsky introduced the Gyro-Resonant Accelerator (GYRAC) mechanism [ 15 , 16 ] , which accelerates electrons by sustaining ECR conditions within a magnetic mirror trap with a time-varying magnetic field. The GYRAC concept was experimentally validated in 2017, achieving electron energies on the order of MeV [ 17 ] . Additionally, A. Neishtadt and A. Timofeev demonstrated that autoresonant acceleration plays a crucial role in electron cyclotron heating of plasmas. This occurs as electrons can maintain the ECR condition while moving along magnetic field lines toward regions of increasing magnetic field strength [ 18 ] . This mechanism, known to as spatial autoresonance, has laid the foundation for the design of accelerator cavities dedicated to electron beams [ 19 , 20 , 21 , 22 , 23 ] . In such systems, the magnetostatic field profile is carefully designed to preserve the resonance condition, ensuring that the microwave frequency matches the cyclotron frequency along the electron trajectory. A novel compact accelerator, known as the Rotating-Wave Accelerator (RWA), was proposed by Velazco et al [ 22 , 23 ] , which operates on spatial autoresonance principles in a \mathrm{TM}_{110} transverse magnetic mode. This acceleration mechanism has also been theoretically studied, further exploring its feasibility and optimization [ 24 ] . Another notable advancement is Spatial Autoresonance Acceleration (SARA), which utilizes a transverse electric field in the TE_{11p} mode ( p=1,2,3 ). This method has been theoretically studied [ 19 ] , and has led to the patenting of an X-ray source based on the SARA concept [ 20 ] . In this study, we focus on the design and numerical simulation of a RF accelerator based on the SARA mechanism. Using a cylindrical cavity excited in the \mathrm{TE}_{112} mode, electron acceleration was modeled with COMSOL Multiphysics, allowing us to derive practical design parameters. Our simulation results show good agreement with those obtained via numerical solutions of the relativistic Newton-Lorentz equation using the Boris method, as reported in [ 25 , 26 ] . While the potential of the SARA mechanism for compact X-ray source development has been previously identified, this work makes a significant contribution by providing optimized design parameters for its practical implementation. 2 Theoretical Foundation and Simulation Framework of the SARA-Based RF Accelerator 2.1 SARA Mechanism This study focuses on an RF accelerator based on the Spatial Autoresonance Acceleration (SARA) mechanism [ 19 , 20 , 21 ] , designed to accelerate low-energy electron beams within a resonant cavity excited in a \mathrm{TE}_{11p} mode ( p=1,2,3 ). This mechanism enables sustained electron acceleration by keeping them in a regime close to the electron cyclotron resonance (ECR) condition along their trajectory, achieved through a carefully tailored magnetostatic field. This approach facilitates efficient and continuous energy transfer within a compact structure. In a vacuum cylindrical cavity with perfect electric conductor (PEC) boundaries, the electric and magnetic field components of the \mathrm{TE}_{11p} mode with linear polarization are given by: \displaystyle E_{r}^{hf} \displaystyle=-\frac{2E_{0l}}{k_{\perp}r}J_{1}\left(k_{\perp}r\right)\sin\theta\sin\left(k_{z}z\right)\sin{\left(\omega t+\psi_{0}\right)}, (1) \displaystyle E_{\theta}^{hf} \displaystyle=-2E_{0l}J_{1}^{\prime}\left(k_{\perp}r\right)\cos\theta\sin\left(k_{z}z\right)\sin{\left(\omega t+\psi_{0}\right)}, \displaystyle B_{r}^{hf} \displaystyle=2E_{0l}\frac{k_{z}}{\omega}J_{1}^{\prime}\left(k_{\perp}r\right)\cos\theta\cos\left(k_{z}z\right)\cos{\left(\omega t+\psi_{0}\right)}, \displaystyle B_{\theta}^{hf} \displaystyle=-\frac{2E_{0l}}{k_{\perp}r}\frac{k_{z}}{\omega}J_{1}\left(k_{\perp}r\right)\operatorname{sin}\theta\cos\left(k_{z}z\right)\cos{\left(\omega t+\psi_{0}\right)}, \displaystyle B_{z}^{hf} \displaystyle=2E_{0l}\frac{k_{\perp}}{\omega}J_{1}\left(k_{\perp}r\right)\cos\theta\operatorname{sin}\left(k_{z}z\right)\cos{\left(\omega t+\psi_{0}\right)}, where the superscript “hf” refers to the high-frequency field. The parameters k_{\perp}=S_{11}/a (with S_{11}=1.841) and k_{z}=p\pi/L represent the transverse and longitudinal wavenumbers, respectively. Here, L and a denote the length and radius of the cavity. The parameter E_{0l} corresponds to the maximum amplitude of the electric field, while the angular frequency of the electromagnetic wave is given by: \omega=c\sqrt{k_{z}^{2}+k_{\perp}^{2}}, (2) where c is the speed of light in vacuum. Additionally, the parameter \psi_{0} is an arbitrary phase. In this work, we focus on the \mathrm{TE}_{112} mode, whose electric field distribution is illustrated in Fig. 1 . Figure 1: Electric field vector profile and corresponding field strength distribution of the TE_{112} mode in the planes: (a) x=0 , (b) y=0 , and (c) z=L/4 . These visualizations illustrate the spatial structure and intensity of the electric field components within the resonant cavity. When K_{\perp}r<1 , the Bessel function J_{1}(K_{\perp}r) can be approximated as J_{1}(K_{\perp}r)\approx K_{\perp}r/2 . Under this approximation, the field equations describe a linearly polarized standing plane wave; which can also be expressed as the superposition of two