The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam
P. D. Winney · 2025
Read The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam by P. D. Winney (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-05423.txt.
Introduction
A large CMS collaboration team reports, in a 2025 paper, beam tests of a prototype detector that will watch over the Large Hadron Collider's upgraded run. The device, the Fast Beam Condition Monitor, measures beam brightness and background junk in real time. It must survive fierce radiation. Its custom chip times signals to within a few nanoseconds and reports when each pulse arrives and how long it lasts.
The team fired hadron, muon, and electron beams at prototypes using two candidate silicon sensor designs. They also tested chips and sensors pre-damaged by radiation to mimic end-of-life conditions. The results fixed key design choices: bonding the sensor directly to the chip, and the operating voltage and threshold settings. The test board design passed and now feeds the first full module. The authors call the tests a major step toward the final detector.
Catalog record
| CREATOR | P. D. Winney |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 67 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-05423
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam P. D. Winney Abstract The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector’s lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector. 1 Introduction 1.1 Motivation and requirements for the dedicated CMS luminosity detector The Fast Beam Condition Monitor (FBCM) is a standalone luminometer designed for precision luminosity measurements and beam-induced background (BIB) [ 1 ] monitoring that exploits silicon (Si) pad sensors with a fast, untriggered readout. It is part of the upgrade of the CMS experiment for the High-Luminosity LHC (HL-LHC) era, developed within the Beam Radiation, Instrumentation, and Luminosity (BRIL) project. A precise luminosity measurement is critical for numerous CMS measurements, and the target precision is set to about 2% in real time (online) and below 1% after data post-processing (offline) [ 1 ] . Response linearity and stability are two key aspects which define the design of a luminometer. The linearity of FBCM was studied and optimized in simulations [ 1 ] for an average rate of interactions per bunch crossing (also referred to as pileup) up to \langle{PU}\rangle=200 . Linearity across a wide pileup range is essential as the specialized calibration runs are conducted at a low pileup of \langle\text{PU}\rangle\approx 0.5 a few times per year, while standard physics data taking in proton-proton collisions during HL-LHC operations will occur at \langle\text{PU}\rangle\approx 140-200 . The stability of the luminometer is influenced by operational aspects, as well as the aging of the sensors and electronics under radiation exposure. The simple and modular design of FBCM uses radiation-hard components for efficient operation until its scheduled replacement in the middle of the HL-LHC period. The expected total ionizing dose (TID) at that time is estimated to be approximately 80 MRad at the location of the Si-pad sensors at a radius of R=14.5 cm, corresponding to a 1 MeV neutron equivalent fluence of about 1.5\times 10^{15}cm^{-2} and an integrated luminosity of about 2000 \text{fb}^{-1} . To facilitate real-time validation and monitoring of the luminometer performance, and to provide precise estimates of systematic biases, multiple independent luminometers using different technologies are necessary at a hadron collider experiment. Multiple CMS subsystems, designed and used primarily for physics measurements, will also be utilized as luminometers: the outermost layer of the outer tracker – consisting of double-sided Si-strip modules; the endcaps of the inner Si-pixel tracker – including the innermost ring of the last (fourth) disk that will be fully dedicated to luminosity measurements; the forward hadron calorimeter; the barrel muon system; as well as the level-1 trigger data scouting system – providing access to various trigger objects at 40 MHz [ 1 ] . This approach allows robust and continuous luminosity reporting to the LHC during collisions and monitoring of the beam-induced background at all times when beams are present in the accelerator. Since the BRIL project does not control the operation of the CMS subsystems, a critical need arises for at least one dedicated detector optimized for luminosity measurement with sub-bunch-crossing time resolution, such as the Fast Beam Condition Monitor discussed in this paper. 1.2 FBCM detector overview A first design of the FBCM was presented in 2021 in the BRIL Phase-2 Technical Design Report [ 1 ] . Since then, extensive development work was performed to improve, validate, and finalize the design. It lead to the (pre-)production and testing of a dedicated front-end ASIC [ 2 ] and various printed circuit boards (PCB) for prototyping the individual components [ 3 ] , the finalization of the readout, control and powering systems, as well as the cabling plan, and the production of a real size mock-up [ 4 ] . The FBCM is designed to operate independently of the CMS central trigger and data acquisition systems, functioning continuously with triggerless readout. It employs a dedicated front-end application-specific integrated circuit (ASIC) to amplify signals from CO 2 -cooled silicon-pad sensors, offering nanosecond-level timing resolution to measure luminosity and beam-induced background. The modular system consists of two half-discs, each containing twelve modules, installed at both ends of the CMS detector, approximately 280 cm from the interaction point. Service electronics are positioned near the outer edge of the half-discs to mitigate radiation-related aging. The electronics design reuses components from the CMS Tracker for power, control, and readout. The FBCM23 ASIC features six channels with adjustable shaping times, enabling fine tuning to match the sensor leakage current. The FBCM mechanics are described in more detail in Subsec. 1.2.1 , electronics – in Subsec. 1.2.2 , and sensors – in Subsec. 1.2.3 . 1.2.1 FBCM detector mechanics The latest design of the FBCM half disks is shown in Fig. 1 both from front and back views, the former with and without the carbon support sheets to reveal the position of the cooling loop. The cooling loop passes behind the front-end modules, close to the inner edges, and is bent to cover the inner half of the portcard cooling frames, maximizing the cooling efficiency [ 4 ] . FBCM is modular, with four repeating segments on each half disc. One of them is shown up close in Fig. 2 on the left, together with the updated design of the front-end module on the right. Each segment consists of three front-end modules, each equipped with a six-pad silicon sensor and two FBCM23 ASICs [ 2 ] , one inner tracker (IT) portcard [ 5 , 6 ] for ASIC signal sampling and electrical-to-optical conversion, and one bPOL12V DC-DC converter [ 7 ] (12 V \rightarrow 1.25 V) for powering the front-end and one service board to distribute high-voltage and low-voltage lines. The step-by-step construction process of the half disk is described in Ref. [ 4 ] . Figure 1 : The updated design of the FBCM half disks. Left: front view. Middle: front view without the upper carbon support sheet to reveal the cooling loop. Right: