Ultra-sensitive sizing of individual nanoparticles with an optofluidic microcavity
Shalom Palkhivala, Larissa Kohler, Christian Ritschel, Claus Feldmann, David Hunger · 2025
Read Ultra-sensitive sizing of individual nanoparticles with an optofluidic microcavity by Shalom Palkhivala, Larissa Kohler, Christian Ritschel, Claus Feldmann, David Hunger (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-05236.txt.
Introduction
Shalom Palkhivala and four colleagues present a 2025 optics paper on measuring single nanoparticles without labels or dyes. Knowing the size of particles just a few nanometers across matters for medicine, materials, and pollution studies, but many label-free methods are slow or give no numbers. The team built a tiny fluid-filled optical cavity that senses particles as they wander through its light field.
The cavity's high bandwidth captures the particles' jittery diffusion in full, and a matching mathematical model turns that motion into a size. The method sizes individual particles down to three nanometers with high precision and accuracy, according to the authors. Such a tool could let researchers watch single particles and their movements in real time.
Catalog record
| CREATOR | Shalom Palkhivala, Larissa Kohler, Christian Ritschel, Claus Feldmann, David Hunger |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 26 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-05236
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Ultra-sensitive sizing of individual nanoparticles with an optofluidic microcavity Shalom Palkhivala, Larissa Kohler, Christian Ritschel, Claus Feldmann, David Hunger Abstract Nanoparticles are ubiquitous, and methods that reveal insights into single-particle properties are highly desired to enable their advanced characterization. Techniques that achieve label-free single-nanoparticle detection often lack bandwidth or do not provide quantitative information. Here, we present a cavity-based dispersive sensing method that achieves a high bandwidth to capture all relevant timescales of translational diffusion, and a sensitivity to detect and size single particles with diameters down to 3 nm. We develop an analytical model describing the autocorrelation function for particle diffusion in a standing-wave sensing geometry and propose a method to address the challenges posed by the transient nature of single-particle signals. With this, we achieve quantitative particle sizing with high precision and accuracy, and provide an important tool to analyze single-particle diffusion. Nanomaterials are often heterogeneous, and methods that give direct access to single particle properties can open up the view into the details of the distribution, reveal features that are otherwise washed out in ensembles, and enable the studies of dynamical behaviour. Therefore, a range of label-free single-particle sensing techniques has been developed. For example, interferometric scattering microscopy (iSCAT) [ 1 , 2 ] has enabled the detection of single nanoparticles and biomolecules [ 3 ] with sizes below 10 kDa using machine learning algorithms [ 4 ] , and the tracking [ 5 ] or sizing [ 6 ] of single nanoparticles down to 10 nm in diameter. Another approach is the use of nanoplasmonic hot spots, e.g. at the tip of gold nanorods [ 7 , 8 ] , or whispering gallery mode (WGM) resonators with high quality factors such as microspheres [ 9 , 10 ] , which enable real-time detection of single particles as well as quantitative particle sizing [ 11 ] . Very high sensitivity is achievable by combining WGM cavities with nanoplasmonic hot spots [ 12 ] . However, most of these sensors are based on the interaction of the analyte with the near-field and thus the sensor surface, which may constrain and modify diffusion. This can preclude a precise quantification of, for example, the hydrodynamic radius. Open access microcavities avoid this limitation [ 13 , 14 , 15 , 16 ] , but the larger mode volume compared to nanoplasmonic sensors has so far restricted detection and sizing to particles >~100 nm. Only recently, open cavities could achieve sensitivities for single molecules down to \sim 1 kDa using a highly non-linear photothermal regime [ 17 ] . Although this remarkable sensitivity has allowed for single protein detection, extracting information relating to the size or shape with this approach has remained limited to the statistics obtained from many detection events. In addition, the influence of the photothermal response that convolves with the signal makes quantitative and unbiased evaluation challenging. Here, we operate a fiber Fabry-Perot microcavity locked on the slope of a resonance in the linear dispersive regime. Using a high finesse of around 55,000 and a high stability with cavity length fluctuations of about 300 fm, we achieve a sensitivity capable of detecting individual 3 nm gold nanoparticles that diffuse through the cavity mode. With a detection bandwidth that is in principle limited only by the decay rate of the cavity ( \sim 500 MHz), we can obtain sufficient statistics from single-particle transits through the cavity mode to calculate the autocorrelation function (ACF) for further analysis. While such an analysis is well established for ensemble techniques such as fluorescence correlation spectroscopy (FCS) and dynamic light scattering (DLS) [ 18 ] , the scenario studied here raises two central aspects that require careful attention: First, the probing volume in FCS is well approximated by a 3D Gaussian that can be treated with an analytical model for the ACF, while a cavity standing wave has a more complex structure that requires a reformulation of this model. Second, the extraction of diffusion time constants and hydrodynamic radii from the ACF relies on the assumption of a stationary system, which can be satisfied by an ensemble with a constant average concentration. In contrast, single particle events are intrinsically non-stationary. We address both aspects and propose an analytical model for the ACF of particle diffusion through a standing wave probe volume, and introduce an analysis that minimizes undesired influence of the transient single-particle behavior. With this methodology, we perform quantitative particle sizing for a range of nominal particle diameters and obtain size distributions that are in good agreement with reference measurements performed with DLS and transmission electron microscopy (TEM). This opens the way to quantitatively assess nanomaterials such as unlabeled biomolecules in their native environment, and could allow further dynamic processes such as rotation and conformational changes to be investigated in the future. Figure 1 : (a) Illustration of gold nanospheres diffusing through an optofluidic fiber Fabry-Perot microcavity. (b) The optoelectronic setup for active cavity stabilization. The two cavity fibers are inserted into a glass ferrule with a lateral microfluidic channel. Piezoelectric transducers (PZT) driven by an arbitrary function generator (AFG) and proportional-integral-derivative (PID) feedback controller allow to tune the cavity mirror separation and to actively stabilize the cavity on the slope of a resonance respectively. For a detailed description, see Methods. (c) Detection of dispersive resonance shifts induced by nanoparticles via changes in transmission of a locked cavity. I Results I.1 The locked optofluidic microcavity Fabry-Perot microcavities with high finesse strongly enhance the interaction between light and matter in the cavity mode volume, and therefore are powerful tools for the label-free detection of single nanoparticles in aqueous dispersion. Similarly to previous work [ 15 ] , we use a fiber-based optofluidic microcavity comprising two single-mode optical fibers inserted into a fiber-optic ferrule, with a microfluidic channel drilled into the ferrule perpendicular to the fibers, such that the cavity between the two fiber tips is immersed in water, see Fig. 1 (a, b). The optical fibers are processed by laser machining to produce concave profiles with radii of curvature between 20 µm and 80 µm, and then coated with a highly reflective Bragg mirror having transmission \mathcal{T}= 20 ppm in air [ 19 ] . We implement an actively stabilized cavity locked on the side of a resonance using a side-of-fringe-lock with an FPGA-based feedback circuit with a unity-gain bandwidth of 80 Hz, which is well below the frequency range covered by nanoparticle diffusion. In comparison to previously reported length-modulated cavities [ 15 , 13 ] , the locked cavity offers the possibility of measurements at much higher bandwidth, limited essentially only by the cavity linewidth. The cavity lengths used in our experiments were 3.7 – 4.5 µm and the cavity finesse in water was {4.5\times 10^{4}}-{5.8\times 10^{4}} . Under active stabilization, the microcavity shows a root-mean-square optical length instability of \sim 300 fm, which corresponds to about 5% of the linewidth, over several hours. The cavity-locked transmission trace is illustrated in Fig. 1 . We note that even the passively stable cavity shows high stability on short timescales (up to seconds), providing a low noise background for the measurements. I.2 Detection of single nanoparticles A small particle with polarizability \alpha diffusing though the optical