Measuring spatial coherence of quantum and classical light with an ultrastable monolithic interferometer
Edoardo Suerra, Mirko Siano, Bruno Paroli, Samuele Altilia, Marco A. C. Potenza, Matteo G. A. Paris, Simone Cialdi · 2025
Read Measuring spatial coherence of quantum and classical light with an ultrastable monolithic interferometer by Edoardo Suerra, Mirko Siano, Bruno Paroli, Samuele Altilia, Marco A. C. Potenza, Matteo G. A. Paris, Simone Cialdi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-01512.txt.
Introduction
Edoardo Suerra and his six co-authors, publishing in 2025, describe an instrument for measuring how orderly a beam of light is across its width, a property called spatial coherence. It matters for both ordinary light and the entangled photons of quantum optics. Their device is a single-block interferometer, carved to be inherently stable, so alignment survives handling and time.
Two matching calcite crystals steer the beams through the block, exploiting the crystals' double refraction. A down-conversion source supplies quantum light and a thermal source the classical kind, so one bench tests both. The team reads coherence two ways, from timing patterns and from spectra, and the methods agree with theory. They pitch the instrument as a robust, automatable standard for labs that need quick coherence checks across very different light sources.
Catalog record
| CREATOR | Edoardo Suerra, Mirko Siano, Bruno Paroli, Samuele Altilia, Marco A. C. Potenza, Matteo G. A. Paris, Simone Cialdi |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-01512
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Measuring spatial coherence of quantum and classical light with an ultrastable monolithic interferometer Edoardo Suerra, Mirko Siano, Bruno Paroli, Samuele Altilia, Marco A. C. Potenza, Matteo G. A. Paris, Simone Cialdi Abstract We describe a monolithic interferometer for spatial coherence measurements of both classical and quantum light sources. The design combines parametric down-conversion with a thermal source, using two identical calcite crystals to control beam alignment via birefringence. The monolithic structure ensures inherent stability. Spatial coherence is measured through temporal interferograms and spectral analysis, with both methods showing close agreement with theoretical predictions. The system is robust and performs reliably for both quantum and classical light. Its design enables automated, rapid coherence measurements across different source types. July 2025 1 Introduction Spatial coherence is a fundamental property of both classical and non-classical light [ 1 , 2 , 3 , 4 ] . It describes the ability of an electromagnetic field to maintain a fixed phase relation between different points across the beam profile [ 2 ] , and is traditionally quantified through the visibility of interference fringes in a Young’s double-slit experiment [ 5 , 4 ] . From a classical perspective, spatial coherence is of utmost importance in many research areas and applications, ranging from high-resolution optical microscopy [ 6 ] to wavefront sensing [ 7 ] , from coherent methods in the X-ray sciences [ 8 , 9 ] to free-space optical communications [ 10 , 11 , 12 ] . The coherence properties of the emitted light also carry useful information on the original radiation source, with applications such as measurements of stellar diameters [ 13 ] and non-invasive particle beam diagnostics [ 14 ] . Spatial coherence becomes even more significant in the quantum regime, where it underpins remarkable phenomena such as quantum superposition and entanglement. In this context, the coherence properties of light are not merely classical features, but essential resources for quantum technologies, enabling groundbreaking advancements in quantum information, metrology [ 15 , 16 ] , and imaging [ 17 , 15 ] . In particular, spatial optical correlations play a crucial role in quantum imaging [ 18 ] and super-resolution [ 19 ] , offering new possibilities for metrology, positioning, and high-precision measurements. A striking example is their potential to surpass classical measurement limits; for instance, leveraging the spatial quantum correlations of spontaneous parametric down-conversion (SPDC) emission to detect weak objects could drive significant practical progress [ 15 ] . For these reasons, the characterization of spatial coherence — both in quantum and classical regimes — is of paramount importance, and robust and straightforward methods for measuring the spatial coherence of a source are highly desirable. From the quantum perspective, the spatial properties of light — particularly those of twin photons — were investigated as early as the first experimental observation of parametric down-conversion by Burnham and Weinberg [ 20 ] , who noted that intensity correlations were stronger for specific combinations of detection angles. Subsequent experiments, such as those exploring double-slit interference using twin photons and coincidence counting [ 21 , 22 ] , further elucidated these spatial correlations, with later studies providing more detailed analyses [ 23 , 24 ] . Additional methodologies, including modified Michelson interferometers [ 25 , 26 ] , have also been explored. Numerous approaches have been proposed also for determining the spatial coherence of classical light, including techniques based on Young’s interferometer [ 27 , 28 ] , wavefront folding and shearing interferometers [ 29 , 30 , 31 , 32 ] , random speckle patterns [ 33 , 34 , 35 , 36 ] , gratings [ 37 ] , plasmonic devices [ 38 ] , reversed-wavefront interferometers [ 39 ] , digital micromirror devices [ 40 ] , among others [ 41 ] . Typically, one of the main challenges in experimentally detecting and investigating quantum light lies in the intrinsically low power of quantum states, which often renders them nearly undetectable. As a result, studying their spatial properties, for instance, by translating duplicate copies of the same beam, becomes experimentally impractical. This necessitates the use of intrinsically aligned and highly stable detection systems. In this work, we introduce an interferometric technique based on a monolithic interferometer to measure the spatial coherence of both quantum and classical light sources. The proposed device, which incorporates two calcite crystals, features an inherently ultrastable design that enables precise control over both spatial and temporal beam overlap. Its monolithic architecture ensures intrinsic alignment throughout the measurement process. We demonstrate the effectiveness of this approach by characterizing the spatial coherence of two distinct light sources: a twin-photon source generated via spontaneous parametric down-conversion (SPDC) and a classical thermal source with a longitudinal coherence length on the order of 1\text{\,}\mathrm{\SIUnitSymbolMicro m} . The measured transverse coherence lengths are in excellent agreement with theoretical predictions, highlighting the robustness and accuracy of the method. The paper is organized as follows: Section 2 describes the experimental setup in detail; Section 3 outlines the theoretical framework necessary to describe spatial coherence; Section 4 presents the experimental results; finally, Section 5 concludes the paper with a discussion of the main findings. 2 Monolithic interferometer and experimental setup The monolithic interferometer used in this study is illustrated schematically in Fig. 1 . Figure 1: Schematic of the monolithic interferometer (top) and detailed views of the calcite crystals (bottom). IN: input beam; HWP i : half-wave plates; C i : calcite crystals; POL: polarizer; IRIS: iris diaphragm. Rotation of C 1 by \alpha introduces a time delay \tau , while rotation of C 2 by \gamma produces a vertical displacement \Delta y . It comprises two identical 40\text{\,}\mathrm{mm} -long calcite crystals and follows the design detailed in Ref. [ 42 ] , itself based on the implementation of Ref. [ 43 ] . In this work, we introduce for the first time the possibility of overlapping distinct transverse portions of the beam to probe its spatial coherence using this interferometer. Initially, a beam — either quantum or classical (denoted IN) — is prepared in a horizontal polarization state. A half-wave plate (HWP 1 ) then rotates this polarization to 45\text{\,}\mathrm{\SIUnitSymbolDegree} . The first calcite crystal (C 1 ) separates the vertical (ordinary) and horizontal (extraordinary) components: the extraordinary ray undergoes a spatial walk-off of D=$4.18\text{\,}\mathrm{mm}$ upon exiting C 1 . A second half-wave plate (HWP 2 ) subsequently swaps the polarization components before the beams enter the second calcite crystal (C 2 ). After C 2 , the two paths recombine and are projected onto a 45\text{\,}\mathrm{\SIUnitSymbolDegree} polarizer (POL), producing an interference pattern. An iris (IRIS) restricts the detection to the desired spatial region. The temporal delay \tau between the two arms is controlled by rotating C 1 by a small angle \alpha around its vertical axis (see top view in Fig. 1 ). This rotation introduces an additional free-space path \Delta z=c\,\tau=D\tan{\alpha}\approx D\,\alpha for the extraordinary beam, while any alteration of the internal crystal path due to Snell’s law is negligible. Similarly, rotating C 2 by a small angle \gamma around its optical axis induces a vertical shear \Delta y=D\sin\gamma\approx D\gamma , with a negligible horizontal shift \Delta x=D(1-\cos\gamma)\approx 0 . To maintain optimal interference,