Read TUNABLE WAVELET UNIT BASED CONVOLUTIONAL NEURAL NETWORK IN OPTICAL COHERENCE TOMOGRAPHY ANALYSIS ENHANCEMENT FOR CLASSIFYING TYPE OF EPIRETINAL MEMBRANE SURGERY by An Le 1 , Nehal Mehta 2 , William Freeman 2 , Ines Nagel 2 , Melanie Tran 2 , Anna Heinke 2 , Akshay Agnihotri 2 , Lingyun Cheng 2 , Dirk-Uwe Bartsch 2 , Hung Nguyen 1 , Truong Nguyen 1 , Cheolhong An 1 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-00743.txt.
Introduction
An Le and co-authors classify eye surgery type from post operative scans with a neural network in a 2025 paper, based on the head byline. The task is to tell whether an epiretinal membrane operation also removed the inner limiting membrane, or the membrane alone. Their model builds on a standard image network and reads center scans from optical coherence tomography.
Cleaning steps such as energy cropping and wavelet denoising lifted accuracy from the raw scans. Two tunable wavelet unit designs were then built into the network, letting filter values adjust during training. One design pushed accuracy higher still. The units sat in downsampling, strided convolution, and pooling layers.
Catalog record
| CREATOR | An Le 1 , Nehal Mehta 2 , William Freeman 2 , Ines Nagel 2 , Melanie Tran 2 , Anna Heinke 2 , Akshay Agnihotri 2 , Lingyun Cheng 2 , Dirk-Uwe Bartsch 2 , Hung Nguyen 1 , Truong Nguyen 1 , Cheolhong An 1 |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 21 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-00743
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
TUNABLE WAVELET UNIT BASED CONVOLUTIONAL NEURAL NETWORK IN OPTICAL COHERENCE TOMOGRAPHY ANALYSIS ENHANCEMENT FOR CLASSIFYING TYPE OF EPIRETINAL MEMBRANE SURGERY Thanks: This article has been supported in part by UCSD Vision Research Center Core Grant P30EY022589, NIH grant R01EY016323, NIH Grant R01EY033847, National Institutes of Health Bridge2AI Project (OT2OD032644), an unrestricted grant from Research to Prevent Blindness, NY, and unrestricted funds from UCSD Jacobs Retina Center. An Le 1 , Nehal Mehta 2 , William Freeman 2 , Ines Nagel 2 , Melanie Tran 2 , Anna Heinke 2 , Akshay Agnihotri 2 , Lingyun Cheng 2 , Dirk-Uwe Bartsch 2 , Hung Nguyen 1 , Truong Nguyen 1 , Cheolhong An 1 Abstract In this study, we developed deep learning-based method to classify the type of surgery performed for epiretinal membrane (ERM) removal—either internal limiting membrane (ILM) removal or ERM-alone removal. Our model, based on the ResNet18 convolutional neural network (CNN) architecture, utilizes postoperative optical coherence tomography (OCT) center scans as inputs. We evaluated the model using both original scans and scans preprocessed with energy crop and wavelet denoising, achieving 72% accuracy on preprocessed inputs, outperforming the 66% accuracy achieved on original scans. To further improve accuracy, we integrated tunable wavelet units with two key adaptations: Orthogonal Lattice-based Wavelet Units (OrthLatt-UwU) and Perfect Reconstruction Relaxation-based Wavelet Units (PR-Relax-UwU). These units allowed the model to automatically adjust filter coefficients during training and were incorporated into downsampling, stride-two convolution, and pooling layers, enhancing its ability to distinguish between ERM-ILM removal and ERM-alone removal, with OrthLatt-UwU boosting accuracy to 76% and PR-Relax-UwU increasing performance to 78%. Performance comparisons showed that our AI model outperformed a trained human grader, who achieved only 50% accuracy in classifying the removal surgery types from postoperative OCT scans. These findings highlight the potential of CNN based models to improve clinical decision-making by providing more accurate and reliable classifications. To the best of our knowledge, this is the first work to employ tunable wavelets for classifying different types of ERM removal surgery. I Introduction The retina is a sensory tissue that converts light into neural signals for vision. It consists of ten layers, from the internal limiting membrane (ILM) to the retinal pigment epithelium (RPE) [ 1 ] . An epiretinal membrane (ERM), a fibrocellular layer of glial cells, fibroblasts, or macrophages, can form on the ILM, distorting retinal layers and impairing vision [ 2 ] . ERM surgery, involving ERM removal with or without ILM peeling, improves retinal structure and function [ 3 ] . While ILM removal may reduce ERM recurrence [ 4 ] , it is linked to micro-scotomas, reduced retinal sensitivity, and delayed visual recovery [ 5 ] , making it a debated topic. Optical coherence tomography (OCT) is commonly used for ERM assessment, but distinguishing ILM removal from postoperative scans remains challenging and often requires surgical notes. This work explores the use of artificial intelligence (AI) to analyze postoperative OCT scans and determine ILM removal, offering a tool for clinical follow-up and insight into structural differences between surgical techniques. To the best of our knowledge, this is the first study to develop a convolutional neural network (CNN) model for determining ERM surgery types using postoperative OCT scans. ResNet18 [ 6 ] was used as the baseline model with center OCT scans as input. To enhance accuracy, we introduced two preprocessing steps: energy-crop and wavelet denoising. Building on prior work [ 7 , 8 ] , we incorporated two tunable wavelet units: OrthoLatt-UwU, enforcing orthogonality and perfect reconstruction through an orthogonal lattice structure, and PR-Relax-UwU, relaxing the perfect reconstruction constraint. These units replaced traditional stride-convolution, downsampling, and pooling functions in ResNet18. Unlike max-pooling [ 9 ] and average-pooling [ 10 ] , which discard fine-grained details, these units preserve both low-pass and high-pass features, improving the model’s ability to distinguish between ERM-only and ERM-ILM removal surgeries. Fig. 1: Visualization of the ERM-only/ERM-ILM removal surgery classification pipeline based on OCT center scan input. AI classifications were compared with those of a trained ophthalmologist, who achieved 50% accuracy. The best ResNet18 model using original OCT scans reached 66%, while preprocessing improved accuracy to 72%. Further integration of OrthoLatt-UwU and PR-Relax-UwU increased accuracy to 76% and 78%, respectively. These results demonstrate that CNN-based AI models outperform human graders and highlight the effectiveness of preprocessing and tunable wavelet unit integration in postoperative OCT analysis. This is also the first study to employ tunable wavelets in AI models for medical imaging applications. II Literature Review Many studies indicate that ILM removal can alter the inner retinal layers, potentially affecting the integrity and function of remaining retinal cells [ 11 ] . Macular surgical techniques continue to advance toward minimizing tissue trauma, ensuring stable anatomical and visual outcomes, and preventing recurrence [ 12 , 13 ] . With AI increasingly integrated into medical practice, its potential to refine surgical techniques is gaining recognition [ 14 ] . This capability is particularly useful for detecting subtle OCT changes that human observers might overlook and for patients transitioning to a new physician without access to prior surgical notes. Current research on tissue changes after ERM peeling relies primarily on histological analysis of ex vivo samples, limiting real-time retinal assessment during surgery [ 15 , 16 ] . While histopathology provides valuable post-surgical insights, it is impractical for routine use. In contrast, OCT is widely accessible and commonly used both preoperatively and for follow-up, making it an ideal tool for retinal evaluation [ 17 , 18 ] . Hence, AI-assisted analysis of postoperative OCT scans could help determine whether ERM alone or both ERM and ILM were removed, offering a valuable tool for retina surgeons. However, to the best of our knowledge, no prior studies have employed AI to detect structural differences between ERM-only and ERM-ILM removal using postoperative OCT scans. III Method An OCT scan processing pipeline was developed to classify ERM-only and ERM-ILM removal surgeries, as shown in Fig. 1 . The pipeline consists of preprocessing and a CNN-based classification model. Preprocessing includes energy-crop, which removes non-essential regions using vertical pixel energy, and wavelet denoising, which filters high-frequency noise while preserving details. ResNet18 serves as the base CNN model, enhanced with OrthLatt-UwU and PR-Relax-UwU units to retain fine details and high-frequency features, reducing information loss from max-pooling. III-A Preprocessing Procedure Fig. 2: Visualization of the Energy-Crop procedure. The image cropping process is performed using a threshold value defined as Threshold=mean-a\times StandardDeviation , where a is the control parameter. III-A 1 Energy-Crop The energy-crop method is designed to remove image areas with little meaningful information, as essential structural details are typically concentrated near the center of an OCT scan. This process uses an adaptive approach to select the relevant area by applying a threshold based on the pixel energy for each vertical coordinate. The pixel energy E_{y} at a vertical coordinate y is defined as follows: E_{y}=\sum_{x}|p_{x,y}|, (1) where p_{x,y} is the pixel value at coordinate (x,y) in which x and y represent the horizontal and vertical coordinate indices, respectively. The thresholding value for cropping the image is defined as Threshold=mean-a\times StandardDeviation , where mean and StandardDeviation represent the average and standard deviation of all E_{y} , with the controlling parameter a