Physics-Informed Neural ODEs for Temporal Dynamics Modeling in Cardiac T 1 T_{1} Mapping

Nuno Capitão *, Yi Zhang *, Yidong Zhao, Qian Tao · 2025

Read Physics-Informed Neural ODEs for Temporal Dynamics Modeling in Cardiac T 1 T_{1} Mapping by Nuno Capitão *, Yi Zhang *, Yidong Zhao, Qian Tao (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-00613.txt.

Introduction

Nuno Capitão and co-authors speed up in 2025 a heart scan that maps tissue health, by teaching a neural model the physics of the signal itself. The scan measures T1, a magnetic relaxation time that flags diseased heart muscle. The standard method needs eleven breath held images with rests between, hard for patients who cannot hold their breath, and then a slow pixel by pixel curve fit.

Their framework replaces the fit with a physics informed neural ordinary differential equation model that follows the signal's recovery over time. A continuous time recurrent design lets the scanner take fewer, flexibly timed snapshots. From that sparse subset the model estimates T1 accurately, for both plain and contrast enhanced scans, and finds the signal's null point fast. Honoring the physics, the authors argue, buys shorter scans that frail patients can finish, with maps a clinician can trust.

Catalog record

CREATORNuno Capitão *, Yi Zhang *, Yidong Zhao, Qian Tao
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2507-00613

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Physics-Informed Neural ODEs for Temporal Dynamics Modeling in Cardiac T 1 T_{1} Mapping Nuno Capitão *, Yi Zhang *, Yidong Zhao, Qian Tao Abstract Spin-lattice relaxation time ( T 1 T_{1} ) is an important biomarker in cardiac parametric mapping for characterizing myocardial tissue and diagnosing cardiomyopathies. Conventional Modified Look-Locker Inversion Recovery (MOLLI) acquires 11 breath-hold baseline images with interleaved rest periods to ensure mapping accuracy. However, prolonged scanning can be challenging for patients with poor breathholds, often leading to motion artifacts that degrade image quality. In addition, T 1 T_{1} mapping requires voxel-wise nonlinear fitting to a signal recovery model involving an iterative estimation process. Recent studies have proposed deep-learning approaches for rapid T 1 T_{1} mapping using shortened sequences to reduce acquisition time for patient comfort. Nevertheless, existing methods overlook important physics constraints, limiting interpretability and generalization. In this work, we present an accelerated, end-to-end T 1 T_{1} mapping framework leveraging Physics-Informed Neural Ordinary Differential Equations (ODEs) to model temporal dynamics and address these challenges. Our method achieves high-accuracy T 1 T_{1} estimation from a sparse subset of baseline images and ensures efficient null index estimation at test time. Specifically, we develop a continuous-time LSTM-ODE model to enable selective Look-Locker (LL) data acquisition with arbitrary time lags. Experimental results show superior performance in T 1 T_{1} estimation for both native and post-contrast sequences and demonstrate the strong benefit of our physics-based formulation over direct data-driven T 1 T_{1} priors. Figure 1: MOLLI 3(3)3(3)5 reconstruction scheme illustrating signal recovery with and without polarity recovery. The corresponding temporally ordered MOLLI T 1 T_{1} -weighted images are shown above. 1 Introduction Quantitative Magnetic Resonance Imaging (qMRI) is a widely adopted noninvasive technique for cardiac parametric mapping, where spin-lattice relaxation time ( T_{1} ) is routinely used as a biomarker to clinically assess myocardial tissue and diagnose cardiomyopathies [ 5 ] . Cardiac T_{1} maps are generated by fitting a parametric model to a series of baseline images that encode signal recovery governed by spin-lattice energy exchange after an inversion pulse. The Modified Look-Locker Inversion Recovery (MOLLI) [ 13 ] sequence has become the standard protocol in cardiac qMRI due to its high precision and reduced motion-induced artifacts. During a single breath hold, MOLLI acquires T_{1} -weighted images at multiple inversion times using distinct Look-Locker (LL) experiments interleaved with rest periods. In a MOLLI 3(3)3(3)5 sequence, three LL experiments collect images in sets of 3, 3, and 5, each separated by three heartbeats. These acquisitions form a image series of 11 baseline images that span the full relaxation curve, as illustrated in Figure 1 . While multiple LL experiments at different inversion times improve T_{1} estimation accuracy, they also extend the breath-hold to 17 heartbeats, which can be strenuous for patients with respiratory issues. Alternative schemes such as Shortened MOLLI (ShMOLLI) [ 14 ] and Saturation Recovery Single-Shot Acquisition (SASHA) [ 3 ] reduce the total number of acquisitions to accelerate imaging, but inherently trade off precision and accuracy [ 18 , 16 ] . Traditional T_{1} map estimation requires voxel-wise nonlinear curve fitting to a signal recovery model derived from MRI physics. This process is further complicated by the need to identify signal polarity transitions (null points) in MOLLI sequences, requiring additional iterative calculations for each pixel. The entire procedure is not only sensitive to image noise but also computationally intensive - processing a complete 3D volume over time has \mathcal{O}(n^{4}) complexity, resulting in significant processing delays in clinical settings without specialized acceleration techniques [ 20 ] . Recent studies have shown that deep learning methods can accurately and efficiently perform cardiac T_{1} mapping using as few as three to five baseline images along the inversion recovery curve, achieving results comparable to conventional MOLLI. [ 4 ] introduced MyoMapNet, a fast myocardial T_{1} mapping model that uses a fully connected neural network (FCNN) to directly map pairwise LL readouts to T_{1} values. However, it neglects signal polarities and is constrained to a data-driven T_{1} prior. In contrast, T1Net [ 11 ] employs a bidirectional long short-term memory (LSTM) network [ 6 ] and adheres to the signal recovery model to enforce consistency between acquired MRI signals and predicted T_{1} values through its loss function. Nonetheless, we hypothesize that T1Net remains limited for several reasons: First, estimating T_{1} maps from a single LL experiment may require non-uniform time intervals to capture the full relaxation curve. Like other discrete recurrent neural networks, LSTMs struggle with irregular time gaps [ 9 , 17 , 1 ] . Furthermore, although enforcing the signal recovery model provides a stronger prior than direct T_{1} estimation, the mechanism by which the model learns the relaxation rate remains a black box, limiting both interpretability and generalization. These limitations highlight the need for a more principled approach that can handle irregular sampling patterns while maintaining physical consistency with the underlying MR signal dynamics. To address these challenges, we introduce a robust and accelerated T_{1} mapping technique using physics-informed neural networks (PINNs) [ 15 ] . We employ a continuous-time LSTM-ODE [ 12 ] that can naturally handle LL sequences with non-uniform acquisition intervals, overcoming the time-gap limitations of traditional recurrent networks. Our Neural Ordinary Differential Equation (NODE) [ 2 ] approach explicitly models the temporal dynamics of the relaxation process, providing a continuous representation of signal evolution rather than discrete approximations. This dynamic modeling not only adheres to the signal recovery model but also explicitly formulates the recovery rate along the relaxation trajectory, ensuring that T_{1} estimation follows the actual physics of spin-lattice interactions. Furthermore, the framework seamlessly incorporates signal polarity correction during inference, eliminating the need for separate processing steps. 2 Methods 2.1 MR Physics-Informed Signal Modeling and Loss Functions To develop our physics-informed approach, we first formalize the MR signal model that governs T_{1} relaxation. In qMRI, N baseline images are collected via selective sampling, with each image capturing the signal at a different point along the relaxation curve. The signal intensity S(x,y,z) at a given spatial coordinate (x,y,z) is described by a parametric function that reflects the underlying physics. In a MOLLI sequence, the signal recovery follows a 3-parameter model expressed as: S_{(x,y,z)}(t_{i})=c_{(x,y,z)}\cdot(1-k_{(x,y,z)}\cdot\exp(-\frac{t_{i}}{T_{1,(x,y,z)}^{*}})), (1) where i\in\{1,2,\dots,N\} and t_{i} is the inversion time of the i -th image. The parameter set \{c,k,T_{1}^{*}\} is estimated at each voxel v\in\mathbb{R}^{x\times y\times z} to determine T_{1} biomarker using the following equation: T_{1(x,y,z)}=T_{1,(x,y,z)}^{*}\cdot(k_{(x,y,z)}-1). (2) While Equations ( 1 ) and ( 2 ) provide the foundation for conventional T_{1} mapping, they represent a static view of the relaxation process. Our approach incorporates the underlying physical dynamics governing spin-lattice relaxation by explicitly modeling the temporal evolution of the signal. By differentiating Equation 1 , we derive a first-order differential expression that captures the instantaneous rate of change at each inversion time t_{i} : \frac{dS_{(x,y,z)}(t_{i})}{dt}=\frac{c_{(x,y,z)}\cdot k_{(x,y,z)}}{T_{1,(x,y,z)}^{*}}\cdot\exp\left(-\frac{t_{i}}{T_{1,(x,y,z)}^{*}}\right). (3) This differential formulation enables our model to learn not just the signal values but also their temporal dynamics, providing a more complete physical representation of the relaxation process. To incorporate both data-driven priors and physics-based constraints into our deep-learning framework, we define a physics-informed loss function with two components: a T_{1} consistency loss \mathcal{L}_{T_{1}} and a physics-based loss \mathcal{L}_{\text{physics}} . \mathcal{L}_{T_{1}}=\frac{1}{HWD}\sum_{(x,y,z)}\|T_{1}-\hat{T_{1}}\|_{2}^{2}, (4) where T_{1} is derived from

Read the complete text