Read Accurate and Efficient Fetal Birth Weight Estimation from 3D Ultrasound by Jian Wang, Qiongying Ni, Hongkui Yu, Ruixuan Yao, Jinqiao Ying, Bin Zhang, Xingyi Yang, Jin Peng, Jiongquan Chen, Junxuan Yu, Wenlong Shi, Chaoyu Chen, Zhongnuo Yan, Mingyuan Luo, Gaocheng Cai, Dong Ni, Jing Lu (🖂), Xin Yang (🖂) (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-00398.txt.

Introduction

Wang and a large team present a study from twenty twenty-five on estimating fetal birth weight from three-dimensional ultrasound. Exact weight forecasts guide delivery choices and cut newborn deaths. Clinic methods are slow, operator-bound, and weak for complex anatomy. Prior deep learning uses flat images or video lacking depth cues. Their method is the first to read weight straight from three-dimensional volumes. A multiscale fusion network extracts traits under sparse supervision. Attention steps and a ranking loss shape that network.

A synthetic sample scheme blends head and belly data from distinct fetuses. Semi-supervised learning on those blends lifts accuracy further. Test errors beat prior methods and near a senior doctor's accuracy. Code is posted in public for reuse.

Catalog record

CREATORJian Wang, Qiongying Ni, Hongkui Yu, Ruixuan Yao, Jinqiao Ying, Bin Zhang, Xingyi Yang, Jin Peng, Jiongquan Chen, Junxuan Yu, Wenlong Shi, Chaoyu Chen, Zhongnuo Yan, Mingyuan Luo, Gaocheng Cai, Dong Ni, Jing Lu (🖂), Xin Yang (🖂)
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE21 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2507-00398

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Accurate and Efficient Fetal Birth Weight Estimation from 3D Ultrasound Jian Wang, Qiongying Ni, Hongkui Yu, Ruixuan Yao, Jinqiao Ying, Bin Zhang, Xingyi Yang, Jin Peng, Jiongquan Chen, Junxuan Yu, Wenlong Shi, Chaoyu Chen, Zhongnuo Yan, Mingyuan Luo, Gaocheng Cai, Dong Ni, Jing Lu (🖂), Xin Yang (🖂) Abstract Accurate fetal birth weight (FBW) estimation is essential for optimizing delivery decisions and reducing perinatal mortality. However, clinical methods for FBW estimation are inefficient, operator-dependent, and challenging to apply in cases of complex fetal anatomy. Existing deep learning methods are based on 2D standard ultrasound (US) images or videos that lack spatial information, limiting their prediction accuracy. In this study, we propose the first method for directly estimating FBW from 3D fetal US volumes. Our approach integrates a multi-scale feature fusion network (MFFN) and a synthetic sample-based learning framework (SSLF). The MFFN effectively extracts and fuses multi-scale features under sparse supervision by incorporating channel attention, spatial attention, and a ranking-based loss function. SSLF generates synthetic samples by simply combining fetal head and abdomen data from different fetuses, utilizing semi-supervised learning to improve prediction performance. Experimental results demonstrate that our method achieves superior performance, with a mean absolute error of 166.4 ± 155.9 166.4\pm 155.9 g g and a mean absolute percentage error of 5.1 ± 4.6 5.1\pm 4.6 %, outperforming existing methods and approaching the accuracy of a senior doctor. Code is available at: https://github.com/Qioy-i/EFW . 1 Introduction Accurate estimation of fetal birth weight (FBW) prior to delivery is crucial for making optimal delivery decisions (i.e., vaginal birth or cesarean section) and reducing perinatal mortality [ 14 ] . As shown in Fig. 1 , the standard clinical method for FBW assessment involves a cumbersome procedure: obtaining 2D standard ultrasound (US) planes, measuring biometric parameters, and applying an empirical formula to estimate it [ 6 ] . However, each steps poses significant challenges. First, acquiring standard US planes requires radiologists to deeply understand fetal anatomy and accurately locate the 2D plane in 3D space, which is technically demanding and time-consuming [ 4 ] . Second, both standard plane acquisition and biometric measurements depend heavily on the radiologist’s experience, leading to intra- and inter-observer variability, which affects the accuracy and reproducibility [ 10 ] . Finally, the empirical formulas currently in use are based on regression analysis of a limited set of biometric parameters, failing to account for diverse and complex anatomical variations among different fetuses [ 12 ] . Figure 1: Workflow for conventional 2D US-based and our 3D US-based FBW estimation. To address these clinical challenges, several artificial intelligence-based approaches have been proposed, broadly categorized into three types: (1) Some studies use manually measured parameters and maternal information, applying machine learning methods to predict FBW [ 11 , 21 , 3 ] . (2) Other studies leverage deep learning to predict parameters from standard US planes or videos, followed by applying empirical formulas to estimate FBW [ 1 , 18 , 17 ] . (3) A few studies employ deep learning models to directly predict FBW from standard US videos combined with clinical information [ 16 , 15 , 19 ] . However, to date, no approaches have been developed to comprehensively address all three key challenges. Furthermore, due to the lack of spatial information in 2D US imaging, methods based on it struggle to accurately capture fetal anatomical structures, limiting prediction accuracy. In contrast, as shown in Fig. 1 , 3D fetal US imaging provides more comprehensive anatomical information and reduces reliance on the operator’s technique, making it a promising alternative for estimating FBW [ 9 , 13 , 7 ] . However, its relatively lower resolution and higher noise levels pose challenges for manual biometric measurements and empirical formula-based estimation. Moreover, while 3D US has not yet achieved widespread clinical adoption due to factors like cost and accessibility, it is increasingly available in advanced obstetric settings. This trend highlights the growing need for automated methods that can fully leverage 3D US data and bypass the limitations of handcrafted features and empirical modeling. In this study, we propose the first method for directly estimating FBW from 3D fetal US volumes. The key challenges lie in extracting informative features from large, anatomically complex 3D data under sparse supervision, and addressing data scarcity given the wide prediction space. To tackle these, we introduce a multi-scale feature fusion network (MFFN) that integrates head and abdomen volumes using channel attention and Mamba-based spatial attention. We further design a ranking-based loss based on inter-fetal FBW relationships to improve generalization. To alleviate limited sample size, we propose a synthetic sample-based learning framework (SSLF), which generates new fetal samples by mixing head and abdomen volumes from different fetuses and learns from them via semi-supervised training. The experimental results demonstrate that our method achieves superior performance, exceeding existing methods and approaching the accuracy of a senior doctor. 2 Methodlogy As illustrated in Fig. 2 , our approach consists of a multi-scale feature fusion network (MFFN) and a synthetic sample-based learning framework (SSLF). In MFFN, we integrate channel attention and spatial attention to extract and fuse multi-scale features. Additionally, we design a ranking-based loss function to model the FBW relationships between fetuses. In SSLF, we design a simple yet effective sample synthesis method to expand the dataset and then apply semi-supervised learning to enhance FBW estimation. Figure 2: Overview of the proposed FBW estimation method. 2.1 Multi-scale Feature Fusion Network Due to the significant variations in the spatial scales of fetal anatomical structures, features extracted from a single scale are inadequate for accurate FBW prediction. Thus, we design a multi-scale feature fusion network (Fig. 2 (a)). Problem definition : Let \left\{\left(x_{i}^{h},x_{i}^{a},s_{i}^{h},s_{i}^{a},g_{i},y_{i}\right)|i\in 1,2,...N\right\} denote a mini-batch randomly sampled from the 3D fetal US dataset. Here, x_{i}^{h},x_{i}^{a}\in\mathbb{R}^{1\times D\times H\times W} represent the 3D US volumes of the fetal head and abdomen, where D , H , and W are the depth, height, and width of the volumes, respectively. s_{i}^{h},s_{i}^{a}\in\mathbb{R}^{3} are the voxel spacing in the depth, height, and width directions for the head and abdomen. g_{i}\in\left\{0,1,2,3\right\} is the time interval (in days) from the 3D US scan to delivery. y_{i}\in[0,1] denotes the normalized true FBW, and N is the batch size. During clinical inference, g_{i} is provided by the doctor as the time interval from the 3D US scan to the estimated delivery. To incorporate spacing and time interval information, we expand the dimensions of s_{i}^{h} and g_{i} and concatenate them along the channel dimension with x_{i}^{h} , resulting in a five-channel head volume X_{i}^{h}\in\mathbb{R}^{5\times D\times H\times W} . Similarly, we obtain abdominal volume data X_{i}^{a} . The objective of this study is to predict FBW y_{i} given the input volumes (X_{i}^{h},X_{i}^{a}) . Feature Fusion : We designed a shared network for both head and abdomen data, so their forward computation processes are identical. For simplicity, we describe the computation process using head data as an example. 3DResNet18 [ 23 ] is adopted as the backbone for feature extraction. The features from four intermediate layers, denoted as Z_{i}^{h^{1}},Z_{i}^{h^{2}},Z_{i}^{h^{3}},Z_{i}^{h^{4}} , are extracted. These features are spatially downsampled by factors of 4, 8, 16, and 32, with corresponding channel dimensions of 64, 128, 256, and 512. To enable multi-scale feature fusion at

Read the complete text