Read Control of Power Grids With Switching Equilibria: Ω \Omega -Limit Sets and Input-to-State Stability by Mahmoud Abdelgalil, Vishal Shenoy, Guido Cavraro, Emiliano Dall’Anese, Jorge I. Poveda (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-00240.txt.
Introduction
Mahmoud Abdelgalil and co-authors study power grids whose balance point keeps jumping in a 2025 paper. Modern grids mix classic generators with solar, batteries, and flexible loads, and demand can switch in steps when protection trips, attacks hit, or data centers surge.
Each demand pattern gives the grid its own resting point, so the system hops between modes instead of settling at one. The authors use hybrid systems tools and omega-limit sets, which describe where a system can end up over time. They show a compact safe region that the grid returns to, as long as switching and load drift stay slow enough. The math helps operators trust grids that must ride out sudden demand jumps.
Catalog record
| CREATOR | Mahmoud Abdelgalil, Vishal Shenoy, Guido Cavraro, Emiliano Dall’Anese, Jorge I. Poveda |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 68 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-00240
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Control of Power Grids With Switching Equilibria: Ω \Omega -Limit Sets and Input-to-State Stability Mahmoud Abdelgalil, Vishal Shenoy, Guido Cavraro, Emiliano Dall’Anese, Jorge I. Poveda Abstract This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields —or modes–, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of Ω \Omega -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system. I Introduction The modern power grid integrates a diverse mix of generation resources, ranging from conventional generators (CGs) to distributed energy assets (DEAs). Although DEAs were initially introduced to enhance grid resilience and improve efficiency, they also introduce new challenges. In particular, their performance is affected by changes in prevailing weather conditions, frequency and voltage fluctuations, and increased vulnerability to cyber-attacks [ 1 , 2 ] . These concerns have spurred extensive research on the reliability and failure modes of power networks [ 3 , 4 ] . In the case of failures of frequency-responsive DEAs, each failure mode corresponds to a different net load configuration and different configurations in the overall system inertia and dumping. This difference arises from several factors, including the presence of intermittent loads and the implementation of countermeasures against cyber-attacks. In such scenarios, using the standard swing equation [ 5 ] to model the dynamics of CGs and frequency-responsive DEAs results in a linear, time-invariant system that switches between a finite number of stable vector fields, which in general may have different equilibrium points. As shown in [ 6 , 7 , 8 , 9 ] , the presence of multiple equilibria precludes the use of standard stability analyses, commonly applied in the frequency control literature, which typically only consider switching between vector fields. This necessitates the development of new tools to study the asymptotic behavior of controllers in power systems with switching dynamically aggregated demand. Stability tools from switching systems’ theory have been used to investigate the asymptotic properties of voltage source converters [ 10 ] , leveraging Lyapunov functions to derive estimates of the region of attraction of a stable common equilibrium point. In [ 11 ] , the authors design frequency controllers for power networks with time-varying inertia. In this case, each inertia level corresponds to a different mode, resulting in a nonlinear switching system that was studied using standard Lyapunov arguments. In [ 12 ] , the authors consider the dual objective problem of simultaneously meeting reference requirements and energy balance in energy storage systems. The theory of switching systems has also been used to study time-varying topologies arising due to unreliable communication between multiple agents in networked systems, and voltage regulation in DC microgrids has also been studied under event-triggered switches in [ 13 ] . For a recent survey on switching and hybrid systems’ tools applied to power systems we refer the reader to [ 14 ] . In contrast to these works, this paper considers a setting where the controlled power system exhibits switching dynamics without a common equilibrium point. While this scenario is more representative of practical conditions, it has received considerably less attention due to the complexity of the resulting “stable” behavior when switching occurs sufficiently slowly. Indeed, to the best of our knowledge, a detailed characterization of this behavior and its stability and robustness properties in power networks with primary controllers and dynamic loads have not been previously addressed in the literature. Motivated by the previous background, in this paper we make the following contributions: (i) By modeling each operating mode of the power dynamics as an LTI system, we provide an explicit characterization of a compact set that is asymptotically stable (in a semi-global practical sense) for the switching dynamics whenever the switching is sufficiently slow. This compact set is constructed on the basis of the data of the matrices that characterize each of the modes of the system, and by leveraging a modeling framework based on hybrid dynamic inclusions that encodes the modes of the system as logic states, and the switches as events triggered by a dynamic resetting timer. (ii) By introducing a novel explicit characterization of \Omega -limit sets for switching linear systems, we show that the stability properties of such a set are robust with respect to slow variations of the load aggregation, provided the 2-norm of the difference between any two “internal” matrices characterizing the modes is sufficiently small. (iii) For arbitrarily fast variations of the load, we use a class of hybrid Lyapunov functions to establish an input-to-state stability-like result that characterizes the convergence of the trajectories of the system to a larger set that depends on the distance between the different equilibrium points induced by the loads. (iv) Finally, we validate the theoretical results via numerical simulations on the IEEE 39-bus test system with both CGs and DEAs. To the best of our knowledge, our results provide the first stability characterization for power transmission systems with switching net loads and DEA failures under dwell time conditions in terms of (semi-globally practically) asymptotically and input-to-state stable sets for switching systems with distinct equilibrium points. The rest of this paper is organized as follows. Section II presents the preliminaries and notation. In Section III , we model the power transmission system as a hybrid system present the main stability results. We present numerical simulations in Section V on the IEEE 39-bus test system. Finally, we conclude in Section VI . II Preliminaries We use \mathbb{R}^{n} to denote the n -dimensional Euclidean space and \mathbb{Z}_{\geq 0} for the set of positive integers. The set of non-negative real numbers is denoted by \mathbb{R}_{\geq 0} . We denote the Euclidean norm of x\in\mathbb{R}^{n} by \lvert x\rvert . Given x\in\mathbb{R}^{n} and a closed set \mathcal{A}\subset\mathbb{R}^{n} , the distance of x to \mathcal{A} is denoted \lvert x\rvert_{\mathcal{A}} and it is defined by \lvert x\rvert_{\mathcal{A}}\coloneqq\inf_{y\in\mathcal{A}}\lvert x-y\rvert . Given r>0 , the set \{x\in\mathbb{R}^{n}\,:\,\lvert x\rvert\leq r\} is denoted by r\mathbb{B} . Given a matrix A\in\mathbb{R}^{n\times m} , we use |A| to denote the induced matrix norm of A , defined as |A|:=\sup_{x\in\mathbb{B}}|Ax| . Given two vectors u,v , their concatenation [u^{\top}~v^{\top}]^{\top} is denoted as (u,v) . The closure of a set S\subset\mathbb{R}^{n} is denoted by \bar{S} . The closure of