Lightweight Physics-Informed Zero-Shot Ultrasound Plane Wave Denoising
Hojat Asgariandehkordi*, Mostafa Sharifzadeh*, Hassan Rivaz · 2025
Read Lightweight Physics-Informed Zero-Shot Ultrasound Plane Wave Denoising by Hojat Asgariandehkordi*, Mostafa Sharifzadeh*, Hassan Rivaz (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-21499.txt.
Introduction
Asgariandehkordi and three co-authors clean sound pics with a net taught on the pic itself in this twenty twenty-five paper. Plane-wave shots take many aim turns to build one clear pic. Few turns cut frame pace, yet leave noise and smear in the pic.
Inside, the aim turns split in two sets, each set builds its own pic. Both pics share true flesh forms but bear unlike noise and smear. Those twin pics drill a two-coat net built just for the one pic at hand. The net learns flesh form as what stays put tween the two pics. No drill bank or clean ref pic is asked for at all.
Catalog record
| CREATOR | Hojat Asgariandehkordi*, Mostafa Sharifzadeh*, Hassan Rivaz |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 43 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2506-21499
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Lightweight Physics-Informed Zero-Shot Ultrasound Plane Wave Denoising Hojat Asgariandehkordi*, Mostafa Sharifzadeh*, Hassan Rivaz Abstract Ultrasound Coherent Plane Wave Compounding (CPWC) enhances image contrast by combining echoes from multiple steered transmissions. While increasing the number of angles generally improves image quality, it drastically reduces the frame rate and can introduce blurring artifacts in fast-moving targets. Moreover, compounded images remain susceptible to noise, particularly when acquired with a limited number of transmissions. We propose a zero-shot denoising framework tailored for low-angle CPWC acquisitions, which enhances contrast without relying on a separate training dataset . The method divides the available transmission angles into two disjoint subsets, each used to form compound images that include higher noise levels. The new compounded images are then used to train a deep model via a self-supervised residual learning scheme, enabling it to suppress incoherent noise while preserving anatomical structures. Because angle-dependent artifacts vary between the subsets while the underlying tissue response is similar, this physics-informed pairing allows the network to learn to disentangle the inconsistent artifacts from the consistent tissue signal. Unlike supervised methods, our model requires no domain-specific fine-tuning or paired data, making it adaptable across anatomical regions and acquisition setups. The entire pipeline supports efficient training with low computational cost due to the use of a lightweight architecture, which comprises only two convolutional layers. Evaluations on simulation, phantom, and in vivo data demonstrate superior contrast enhancement and structure preservation compared to both classical and deep learning-based denoising methods. The source code will be released at http://code.sonography.ai upon acceptance. I Introduction Highlights \bullet Introduces a zero-shot residual learning framework tailored to plane wave ultrasound, eliminating the need for training data. \bullet Achieves higher contrast and structural preservation across simulation, phantom, and in vivo datasets compared to supervised learning and classical baselines. \bullet Enables efficient training (even on CPU) using a compact network, broadening practical deployment in ultrasound diagnostics. Ultrasound imaging, a non-invasive and cost-effective diagnostic modality, plays a vital role in modern clinical practice by enabling real-time visualization of internal anatomical structures and pathological conditions. Despite its advantages, such as safety, portability, and affordability, the quality of ultrasound images is often compromised by various types of noise, including speckle and artifacts caused by wave interactions with tissue heterogeneity [ 1 ] . These degradations can limit interpretability and reduce diagnostic confidence. As a result, the development of effective post-processing techniques has become essential to improve image clarity and diagnostic reliability [ 2 , 3 ] . To overcome these challenges, early research on ultrasound image enhancement focused on classical techniques such as spatial and frequency domain filtering, speckle reduction algorithms, and contrast enhancement strategies. While these methods have shown promise, they often fall short in addressing the complexity and variability of ultrasound data. This has motivated the exploration of more adaptive frameworks capable of dynamically adjusting to local image characteristics and structural content [ 4 ] . Recent advances in deep learning have led to significant improvements in medical image restoration, including ultrasound denoising. In particular, supervised Convolutional Neural Networks (CNNs) have demonstrated notable success in recovering clean images from noisy inputs. These models have been widely applied to tasks like speckle suppression, beamforming, and post-compounding enhancement in ultrasound. Their ability to learn complex mappings between noisy and clean domains has made them a compelling choice for data-driven image quality enhancement [ 5 , 6 , 2 , 7 ] . However, supervised learning approaches face critical limitations. They rely on access to large-scale datasets with paired noisy and clean ground truth images. In ultrasound, such ground truth is typically unavailable as there is no standard “clean” reference image, particularly in patient data. Many studies resort to synthetic phantoms acquisitions as solutions, which may not generalize to real-world scenarios. Moreover, these models often lack robustness across imaging domains. Variations in transducer hardware, anatomical regions, or imaging parameters can lead to domain shift, where the performance of a pre-trained model degrades significantly when applied outside its training distribution. To mitigate the dependency on ground truth labels, the field has explored self-supervised learning approaches. These methods train denoising networks using only noisy data, often by masking parts of the input or leveraging spatial or temporal redundancy. Techniques such as Noise2Void, Noise2Self, and Neighbor2Neighbor eliminate the need for paired supervision by learning to predict a pixel from its local or global context [ 8 , 9 , 10 ] . Such frameworks have been adapted to ultrasound and other medical modalities, offering a more flexible alternative to the supervised pipelines [ 11 , 12 , 13 , 14 ] . Yet, self-supervised methods are not without limitations. While they remove the need for ground truth, they still require access to large and diverse datasets during training to learn meaningful noise-signal separation. As with supervised approaches, models trained on specific organs or imaging settings may struggle to generalize to unseen domains. This dependence on extensive data and persistent domain sensitivity reduces their practical applicability in settings with limited data availability or changing clinical conditions. In contrast, zero-shot denoising offers a fundamentally different paradigm. These methods operate entirely on the test image, without requiring any training data. Pioneering examples include Zero-Shot Noise2Noise (ZS-N2N), which trains a lightweight network using spatially downsampled variants of the same noisy image [ 15 ] . Instead of relying on spatial downsampling, we exploit ultrasound physics. Specifically, we partition the available steering angles into two subsets, reconstruct two compounded images that share the same tissue response but exhibit distinct angle-dependent artifacts, and use these images as self-supervised pairs. This physics-informed pairing enables the network to learn, on the fly, to disentangle the consistent tissue signal from the inconsistent artifacts, thereby achieving effective zero-shot denoising without any external training data. Despite their success in natural imaging, zero-shot methods have seen limited application in ultrasound, and even less so in the context of Coherent Plane Wave Compounding (CPWC). In this work, we propose a zero-shot denoising framework tailored for CPWC ultrasound images obtained with a limited number of transmission angles. Our method requires no training data, clean images, or prior noise modeling. Instead, it leverages the angular diversity inherent in the CPWC acquisition by dividing the available angle set into two complementary subsets. Each subset is used to reconstruct a noisier compounded image. These two images are treated as pseudo-pairs for self-supervised residual learning. A lightweight CNN is trained directly using the pseudo-pairs to extract uncorrelated components. Once trained, the model estimates and subtracts noise from the original compounded image to yield a denoised, contrast-enhanced result. The main contributions of this paper are as follows: • Zero-shot CPWC denoising: We tailor zero-shot denoising to the context of CPWC for the first time, enabling image enhancement without requiring any training data. • Customized downsampling: We propose a domain-specific physics-informed angular sampling strategy that adapts the ZS-N2N framework to plane wave ultrasound imaging. The model is trained to disentangle inconsistent artifacts from consistent tissue signal. • Lightweight architecture: We use a lightweight CNN model with only two convolutional layers, supporting efficient training even on conventional CPUs. This design reduces computational training overhead relative to conventional supervised and self-supervised approaches. • Extensive evaluation: We perform a comprehensive evaluation on simulation, phantom,