Novel coincidence detection technique for precision measurement of neutron-capture–induced nuclear recoils Preprint: June 24, 2025

A.J. Biffl, Gerardo Gonzalez, A.N. Villano, N. Mirabolfathi · 2025

Read Novel coincidence detection technique for precision measurement of neutron-capture–induced nuclear recoils Preprint: June 24, 2025 by A.J. Biffl, Gerardo Gonzalez, A.N. Villano, N. Mirabolfathi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-20022.txt.

Introduction

Biffl and co-authors propose a twin-signal method to measure the tiny recoil when a nucleus captures a neutron, in a paper from two thousand twenty-five. Such recoils calibrate detectors, but their energy reading is muddied by crystal damage. Neutron capture offers recoils of a precise, known energy instead.

The plan catches both products of one capture: the emitted gamma ray and the recoiling nucleus. Catching both in coincidence would pin the event down tightly. Simulations with a californium source show a clear measurement is feasible with current detectors. About twenty-six gram-days of exposure would do it, the team finds.

Catalog record

CREATORA.J. Biffl, Gerardo Gonzalez, A.N. Villano, N. Mirabolfathi
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE31 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2506-20022

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Novel coincidence detection technique for precision measurement of neutron-capture–induced nuclear recoils Preprint: June 24, 2025 A.J. Biffl, Gerardo Gonzalez, A.N. Villano, N. Mirabolfathi Abstract Usually, detailed information about particle motions, energies, and interactions in the crystal lattice cannot be directly measured. Neutron capture ( n , γ ) (n,\gamma) can produce detectable, precise-energy nuclear recoils for detector calibration and solid-state physics studies. This paper proposes a first-of-its-kind experiment to measure the twin products of neutron capture – the postcapture deexcitation gamma and postcapture nuclear recoil. Simulations show that with a 1 mCi californium neutron source, a positive measurement with existing detector technologies is possible in 26.1 gram-days of exposure. I Introduction Crystal-based particle detectors have applications for dark matter searches Angloher et al. 2016 ; Agnese et al. 2018a ; Aguilar-Arevalo et al. 2020 ; Armengaud et al. 2022 ; Crisler et al. 2018 ; Billard et al. 2024 , neutrino science Fernandez Moroni et al. 2015 ; Bonet et al. 2021 ; Colaresi et al. 2021 ; Ang et al. 2021 ; Strauss et al. 2017 ; Belov et al. 2015 ; Singh et al. 2017 , and nuclear energy Kim 2016 . In these detectors, especially ones that measure nuclear recoils (NRs), specific knowledge of the dynamics of atoms in the crystal lattice is helpful but is locked behind crystallographic processes. Details about particle motions and energies are obscured, making it difficult to interpret collected data. It is therefore helpful to study events where the energy is known beforehand, to aid in reconstructing the dynamics of the event and to calibrate these detectors. There is still much unknown about the interactions between a recoiling atom and its surrounding crystal lattice during a NR. Formation of crystal defects, direction-dependent effects on recoil energies (e.g., channeling Feldstein et al. 2010 ), and ionization yield are difficult to measure without detailed information about the NRs in question. Crystal defects can warp the spectrum of NR events from DM (dark matter) or CENNS (coherent elastic neutrino-nucleus scatter) Soum-Sidikov et al. 2025 and uncertainty about the energy, time scale, and evolution of defects can hinder experiments and may even be a major source of backgrounds Heikinheimo et al. 2022 ; Anthony-Petersen et al. 2025 . Defect properties have been studied extensively in silicon, with work focusing on defects caused by implanted silicon ions Zhong et al. 2004 or low-energy helium Haynes et al. 2018 , defect annealing after electron irradiation Yeritsyan et al. 2018 , comparison between electron and proton irradiation Emtsev et al. 2012 , effects of an external electric field Hazdra and Dorschner 2003 ; Basheleishvili and Pagava 1999 , and defect concentration after hydrogen implantation Darras et al. 2014 . However, in all these cases the defect properties had to be characterized by measuring bulk material properties (c.f., Srivastava et al. 2023 ; Bathen et al. 2022 ), rather than directly studying the dynamics of defect formation, evolution, and annealing. Ionization yield, the fraction of NR energy given to ionizing electrons, is an extremely important parameter for ionization-based detectors. The most common model for the ionization yield is the Lindhard model Lindhard et al. 1963 , though recent measurements have shown disagreement with the Lindhard model in Si at low energies ( \lesssim keV {}_{\text{ee}} ) Ramanathan and Kurinsky 2020 ; Chavarria et al. 2016 ; Izraelevitch et al. 2017 ; Villano et al. 2022 ; Albakry et al. 2023 . Several modifications have been tried to make up these differences Sorensen 2015 ; Albakry et al. 2022 , though they are ultimately limited by lack of measurement below around 100 eV. Uncertainty in the yield introduces large uncertainties in measured energies and calibrations. This can cause large uncertainties in thresholds and event rates, and thus in reported dark matter limits (c.f., Agnese et al. 2019 §IIA and §VIIIB, and Agnese et al. 2018b §IIA and §VA&B). Thermal neutron capture (n,\gamma) has been proposed as a source of exact-energy NRs for detector calibration Harris et al. 2023 ; Wagner and on behalf of the CRAB Collaboration 2022 ; Amarasinghe et al. 2022 ; it may also serve as a door into direct measurement of defect formation, ionization yield, and other crystal effects in NRs. The excited-state postcapture nucleus emits one or more MeV-scale deexcitation gammas and recoils at its position in the crystal lattice. If this deexcitation happens in a single gamma (a “straight-to-ground” event), the NR will have an exactly known energy, which can be used for detector calibrations and other studies. Capture-induced NRs have previously been measured in silicon Villano et al. 2022 , and the straight-to-ground NR peak from capture on 182 W in \text{CaWO}_{4} has been recently measured by the CRAB Collaboration Abele et al. 2023 ; Kluck et al. 2025 , but the straight-to-ground peak has never been measured in other common detector materials like germanium or silicon. In this paper we propose a new experiment to measure the capture-induced NR signature in silicon and the postcapture deexcitation gammas in coincidence using a gram-scale silicon phonon detector and two kg-scale germanium ionization detectors. This will be the first measurement of the NR peak from capture-induced recoils in silicon, and will be the first time a capture-induced NR is measured in coincidence with the emitted deexcitation gamma. The structure of the paper is as follows: Section II describes the signature of neutron capture in silicon in detail. In Section III the proposed experimental configuration is described. Section IV details simulations carried out to estimate the expected signal rate, background rate, and detector requirements. Discussion and concluding remarks are given in Section V . II Neutron Capture During radiative thermal neutron capture (n,\gamma) , a nucleus absorbs a low-energy ( O(10^{-2}\text{\,eV}) ) neutron. The neutron enters the nuclear system at the neutron separation energy, S_{n} ( \sim MeV), and very quickly ( \sim fs) after the capture the nucleus deexcites to its ground state, emitting a cascade of one or more gammas. Each gamma emission causes a corresponding momentum change of the nucleus, though the cascade is so fast that all of the NR energy comes in a single pulse for all practical detectors. Each individual gamma emission in the deexcitation follows two-body kinematics, but unless the nucleus’s momentum is known at all moments in the intermediate phases of a multi-gamma cascade, reconstructing the exact recoil energy and direction is impossible. However, in the case of a single-gamma cascade we can reconstruct the exact NR energy and direction, assuming the nucleus is at rest before the cascade. In this case, the postcapture nucleus falls directly to the ground state, and the sum of gamma energy and recoil energy is equal to the neutron separation energy. The direction of the NR is opposite the emitted gamma direction. For neutron capture on a nucleus with rest mass M and neutron separation energy S_{n} , the gamma energy E_{\gamma} is: E_{\gamma}=-M+\sqrt{M^{2}+2MS_{n}}\simeq S_{n}-\frac{S_{n}^{2}}{2M} (1) and the kinetic energy of the recoiling nucleus E_{nr} is: E_{nr}=\frac{E_{\gamma}^{2}}{2M}\simeq\frac{S_{n}^{2}}{2M} (2) For {}^{28}\text{Si}(n,\gamma)^{29}\text{Si} , these energies S_{n} , E_{\gamma} , and E_{nr} are given in Table 1 . At finite temperature the energies are broadened by an amount \Delta E\approx S_{n}\sqrt{T/M} . At 20 mK, this

Read the complete text