Integrating Radiomics with Deep Learning Enhances Multiple Sclerosis Lesion Delineation

Nadezhda Alsahanova † \dagger, Pavel Bartenev † \dagger, Maksim Sharaev ([email protected]), Milos Ljubisavljevic, Taleb Al. Mansoori, Yauhen Statsenko ([email protected]) · 2025

Read Integrating Radiomics with Deep Learning Enhances Multiple Sclerosis Lesion Delineation by Nadezhda Alsahanova † \dagger, Pavel Bartenev † \dagger, Maksim Sharaev ([email protected]), Milos Ljubisavljevic, Taleb Al. Mansoori, Yauhen Statsenko ([email protected]) (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-14524.txt.

Introduction

Nadezhda Alsahanova and co-authors improve the outlining of multiple sclerosis lesions in brain scans by adding texture features to deep learning. Their 2025 paper starts from a diagnostic need: exact lesion maps guide care, but current networks falter on varied scans. The team fuse hand-crafted image statistics with the raw scans.

They devise two new features that capture how lesion types differ in concentration and disorder. The fused input feeds two network designs across scans from dozens of patients and over a thousand slices. One design gained clear accuracy, precision, and sensitivity over the scan-only baseline. The other grew more stable, with smoother training curves and less variable scores. Richer inputs, not just bigger networks, drove the gains.

Catalog record

CREATORNadezhda Alsahanova † \dagger, Pavel Bartenev † \dagger, Maksim Sharaev ([email protected]), Milos Ljubisavljevic, Taleb Al. Mansoori, Yauhen Statsenko ([email protected])
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE34 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2506-14524

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Integrating Radiomics with Deep Learning Enhances Multiple Sclerosis Lesion Delineation Nadezhda Alsahanova † \dagger, Pavel Bartenev † \dagger, Maksim Sharaev ([email protected]), Milos Ljubisavljevic, Taleb Al. Mansoori, Yauhen Statsenko ([email protected]) Abstract Background : Accurate lesion segmentation is critical for multiple sclerosis (MS) diagnosis, yet current deep learning approaches face robustness challenges. Aim : This study improves MS lesion segmentation by combining data fusion and deep learning techniques. Materials and Methods : We suggested novel radiomic features (concentration rate and Rényi entropy) to characterize different MS lesion types and fused these with raw imaging data. The study integrated radiomic features with imaging data through a ResNeXt-UNet architecture and attention-augmented U-Net architecture. Our approach was evaluated on scans from 46 patients (1102 slices), comparing performance before and after data fusion. Results : The radiomics-enhanced ResNeXt-UNet demonstrated high segmentation accuracy, achieving significant improvements in precision and sensitivity over the MRI-only baseline and a Dice score of 0.774 ± \pm 0.05; p < 0.001 p<0.001 according to Bonferroni-adjusted Wilcoxon signed-rank tests. The radiomics-enhanced attention-augmented U-Net model showed a greater model stability evidenced by reduced performance variability (SDD = 0.18 ± 0.09 vs. 0.21 ± 0.06; p = 0.03 p=0.03 ) and smoother validation curves with radiomics integration. Conclusion : These results validate our hypothesis that fusing radiomics with raw imaging data boosts segmentation performance and stability in state-of-the-art models. Keywords: radiomics; quantitative MRI; deep learning; data fusion; multiple sclerosis; white matter lesions Acronyms The following abbreviations are used in this manuscript: AM attention mechanism CNN convolutional neural network CR concentration rate FLAIR fluid-attenuated inversion recovery MAGNIMS magnetic resonance imaging in multiple sclerosis ML machine learning MS multiple sclerosis qMRI quantitative MRI RE Rényi entropy SDD standard deviation of derivatives SOTA state-of-the-art Introduction Multiple Sclerosis (MS) is a chronic autoimmune disorder that affects approximately 2.8 million individuals worldwide, making it one of the most prevalent neurological diseases among young adults ( Sadeghibakhi et al. 2022a ). It presents with nonspecific symptoms, e.g., visual disturbances due to optic neuritis, numbness or tingling as sensory symptoms, fatigue, motor weakness and coordination problems. Therefore, early diagnostics of the disease requires advanced image techniques (brain MRI with contrast enhancement) and laboratory tests of cerebrospinal fluid ( Statsenko et al. 2023a ). AI-enhanced neuroimaging has emerged as a promising tool to support clinical decision-making, offering potential improvements in early detection and monitoring ( Siddiqui et al. 2024a ; Onciul et al. 2025a ). Machine learning (ML), particularly convolutional neural networks (CNNs), has demonstrated significant success in automating the detection of brain pathologies ( Aliev et al. 2021a ; Rondinella et al. 2023a ). However, challenges persist in model robustness and the effective integration of lesion-specific knowledge into deep learning frameworks. Radiomics holds promises to address these challenges and enhance ML-based diagnostics by extracting high-dimensional quantitative features from medical images. These features quantify structural heterogeneity and cover such characteristics as texture, shape, and intensity patterns. Recently, radiomics was successfully applied to detect mild cognitive impairment (MCI) by identifying volumetric changes in brain structures ( Zubrikhina et al. 2023a ). Similarly, our prior work demonstrated that combining radiomics with neural networks improves focal cortical dysplasia detection by capturing subtle pathological features often missed in visual assessments ( Alsahanova et al. 2025a ). Attention-augmented U-Nets, have achieved notable performance in MS lesion segmentation, therefore they are considered state-of-the-art (SOTA) approaches ( Rondinella et al. 2023a ). The authors validated SOTA performance through extensive experiments, comparing it against other leading methods on benchmark datasets such as the MICCAI MS lesion segmentation challenge data. Their results demonstrated superior segmentation accuracy (e.g., higher Dice scores), confirming SOTA status of their model. Still, the search for more accurate and robust models remains actual. The demand for accurate automatic delineation of MS lesions stems from radiologists’ need for a tool to assess neuroinflammatory brain changes efficiently. Once developed, this tool will have broad practical implications, supporting the application of MS diagnostic criteria by objectively demonstrating the dissemination of white matter lesions in time and space. High-accuracy quantitative MRI assessment is critical, as the Magnetic Resonance Imaging in Multiple Sclerosis (MAGNIMS) criteria are non-specific, underscoring the need for follow-up examinations with longitudinal comparison of imaging findings. Aims and Objectives This study aims to improve the accuracy and robustness of MS lesion segmentation in MRI scans by combining data fusion and deep learning techniques. Hypothetically , fusion of imaging data with radiomical features retrieved from the same images boosts the performance of the models trained to segment multiple sclerosis lesions from FLAIR images. To reach the study objective we formulated the following tasks: • Develop radiomical features for data fusion and compare radiomics values for different types of MS lesions • Assess the efficiency of ML-based segmentation before and after the data fusion • Test whether fusing radiomics with raw images improves the stability and performance of a recent SOTA model for lesion segmentation. Materials and Methods Study Cohort and Data Preprocessing The study dataset included results MRI findings of the brain of 46 patients treated for MS in Tawam Hospital, Al Ain city. From the PACS server, our team collected diagnostic images of FLAIR sequence – the primary diagnostic modality for detection and delineation of white matter lesions in MS. The images had isometric voxel with the size ranging from 0.8 to 1 mm. Figure 1 shows FLAIR slices with white matter lesion segmentations. The models were trained and tested on the labeled MS lesion dataset containing 1102 slices. Prior to the extraction of radiomical features, we performed intensity normalisation. Figure 1: Examples of FLAIR slices and segmentations. Research Methodology To complete the first task , we resorted to the same radiomical features as in our recent study on focal cortical dysplasia. Concentraion rate (CR) was the most promising feature to use because which captures local hyperintensities while being robust to extreme outliers by excluding the highest values. Equation 1 describes a way to compute CR for a pixel at position (i,j) with scanning window W_{s}(i,j) of size 2s+1\times 2s+1 where s=2 . In the equation, num is a number of high-intensity pixels to sum, m is a number of highest pixels to exclude avoiding outliers, and X_{(k)} is the i -th highest order statistic of gray scales of X in the scanning window W_{s}(i,j) . Herein, N is the total number of pixels in the neighborhood scanning window computed according to Equation 2 . Rényi entropy (RE) was a top performing feature for discovering hyperintense lesions in the white and gray matters in our previous research, which provided rationale to apply RE to the current study ( Alsahanova et al. 2025a ). RE of order \alpha>0,\;\alpha\neq 1 is a measure of “disorder” of gray scales ( Rényi 1960a ; Rényi 1961a ). To calculate it, we used the standard gray-level co-occurrence matrix (GLCM) which records how often pairs of voxels with specific intensity appear at a given distance and direction in the image ( Suresh & Shunmuganathan 2012a ; Chitalia & Kontos 2019a ). RE is calculated for each element f_{k,l} in 256^{2} GLCM matrix as per Equation 3 . We computed GLCMs for distances 1 and 2 pixels across 4 primary directions within the scanning window W_{s}(i,j) (

Read the complete text