Experimental Verification of a Time-Domain Load Identification Method for Single-Phase Circuits
Francisco M. Arrabal-Campos, Francisco G. Montoya, Jorge Ventura, Santiago Sánchez-Acevedo, Raymundo E. Torres-Olguin, and Francisco de León · 2025
Read Experimental Verification of a Time-Domain Load Identification Method for Single-Phase Circuits by Francisco M. Arrabal-Campos, Francisco G. Montoya, Jorge Ventura, Santiago Sánchez-Acevedo, Raymundo E. Torres-Olguin, and Francisco de León (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-12593.txt.
Introduction
Francisco Arrabal-Campos and co-authors test a method to identify the load in a single-phase power circuit from time-based measures, in a 2025 paper. The test took place in a modern smart grid lab with real power hardware and real-time emulators. The method needs only voltage and current readings at the point where the load joins the grid. No extra probes inside the load are required.
Test cases cover both clean sine-wave loads and loads that bend the wave shape. The voltage and current traces are cleaned and then used to work out the circuit values. Results show high accuracy and strength across all cases, with very small errors. The found values agree well with what theory predicts, which supports the method for field use.
Catalog record
| CREATOR | Francisco M. Arrabal-Campos, Francisco G. Montoya, Jorge Ventura, Santiago Sánchez-Acevedo, Raymundo E. Torres-Olguin, and Francisco de León |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2506-12593
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Experimental Verification of a Time-Domain Load Identification Method for Single-Phase Circuits Francisco M. Arrabal-Campos, Francisco G. Montoya, Jorge Ventura, Santiago Sánchez-Acevedo, Raymundo E. Torres-Olguin, and Francisco de León Abstract This paper presents experimental validation of a time-domain load parameter determination method for single-phase circuits. The verification is performed in a state-of-the-art smart grid laboratory equipped with power hardware and real-time emulators. The proposed method enables the identification of circuit parameters using only instantaneous voltage and current measurements at the point of common coupling. The experimental setup includes a range of test cases covering linear and non-sinusoidal single-phase conditions. Voltage and current waveforms are acquired, preprocessed, and used to calculate the relevant circuit parameters. The experimental results demonstrate a high degree of accuracy and robustness, with minimal percentage errors across all test cases. The identified parameters show excellent agreement with the theoretical expectations, confirming the validity and applicability of the proposed method to identify the load of single-phase systems. This validation highlights the potential of the method for improved monitoring, control, and protection of smart grids, paving the way for future extensions to three-phase systems and real-time implementations. I Introduction Modern Electric Power Systems (EPS) have evolved significantly from systems with simple unidirectional power flow to highly complex networks with distributed resources. In addition, the development of electronic systems and computing power has driven the development of sophisticated Information Technology (IT), which has become integrated with power systems. The coupling of EPS and IT is known as Cyber-Physical-Power Systems (CPPS) [ 1 , 2 , 3 ] . CPPS are increasing the amount of computational control, protection, or energy management methods that require accurate knowledge of the system parameters, such as resistance, inductance, and capacitance of the EPS’s loads or lines. Estimation of electric circuit parameters in AC applications is crucial for effective control, protection, and energy management. Accurate parameter estimation are indeed key for enabling advanced grids services such as voltage control [ 4 ] , congestion management and frequency regulation. Moreover, accurate estimation of parameters is essential for protection systems in both distribution or transmission levels, as as load characteristics directly influence short-circuit currents, inrush behavior, and transient responses—making load models critical for reliable fault analysis and protection coordination [ 5 ] . Accurate estimation of the equivalent grid circuits connected to converter-based systems is crucial for enhancing stability margins of power electronic control systems [ 6 ] . In energy management based on integrated energy systems, parameter estimation enables optimal power flows management by capturing load dynamics [ 7 ] . In this context of increasing complexity of modern power systems, reliable methods for circuit parameter identification become essential. To address this demand, a time-domain load parameter identification method for general linear and non-linear single-phase loads was published by a subset of the authors of this paper in 2022 [ 8 ] . Although the theoretical foundation of this approach was showcased through computer simulations, its practical implementation must be validated under real-world conditions. This validation is particularly important given the challenges in parameter estimation for modern power systems with non-linear loads and non-sinusoidal excitations. This paper presents a laboratory-based experimental verification of the proposed method as a critical step toward its future real-time implementation in the field. The problem addressed through simulation in [ 8 ] is experimentally verified in this paper. Based solely on measurements of instantaneous voltage and current at the Point of Common Coupling (PCC), the method is capable of identifying the discrete (and possibly time dependent) RLC parameters of equivalent series or parallel circuits. In other words, the method can identify the resistor R , inductor L , and elastance S (i.e. the inverse of a capacitor) elements of a series equivalent circuit or the conductance G , compliance \Gamma (i.e. the inverse of an inductor), and capacitor C of a parallel equivalent circuit. This paper presents two significant contributions. First, it introduces a practical methodology for the experimental calculation of parameters, specifically addressing the issue of signal noise in the original voltage and current measurements. This novel approach avoids problems associated with parameter estimation associated with ill-posedness in circuit parameter estimation. The second contribution is the experimental validation of the proposed methodology. Prior to this work, the method had not been tested on a physical system. Furthermore, the paper demonstrates how the results obtained in [ 8 ] , which are based on differential geometry and geometric algebra, can also be obtained using a system representation of linear differential function similar to the Wronskian matrix. II Theoretical Background The rigorous mathematical derivation of the identification method was published in [ 8 ] using Geometric Algebra (GA). While geometric algebra is a powerful tool for vector operations, it remains quite unfamiliar to many engineers. This section provides a simplified derivation of the identification expressions using only differentiation of KVL (Kirchhoff Voltage Law) and KCL (Kirchhoff Current Law) to a set of series or parallel equivalent circuits. The following assumptions are made: a) Given that modern instrumentation operates digitally, parameter identification of the load is performed over discrete time intervals rather than continuously. Consequently, all non-linearities are modeled as time-dependent discrete functions. b) The RLC parameters of the equivalent circuits are assumed to remain constant over a time window longer than the sampling period of the measurements. This ensures that the resulting systems of equations are linearly independent, as discussed in [ 9 ] . II-A Series Equivalent Circuit Let v and i be the instantaneous voltage and current measured at the PCC at a constant sampling rate. Applying KVL to a simple RL circuit yields: v=Ri+Li^{\prime} (1) where i^{\prime} is the time derivative of the current i . Taking the first and second derivatives of ( 1 ) yields: \displaystyle v^{\prime} \displaystyle=Ri^{\prime}+Li^{\prime\prime} (2) \displaystyle v^{\prime\prime} \displaystyle=Ri^{\prime\prime}+Li^{\prime\prime\prime} The set of equations in ( 2 ) can be written in matrix form to compute R and L as: \begin{bmatrix}i^{\prime}&i^{\prime\prime}\\ i^{\prime\prime}&i^{\prime\prime\prime}\end{bmatrix}\begin{bmatrix}R\\ L\end{bmatrix}=\begin{bmatrix}v^{\prime}\\ v^{\prime\prime}\end{bmatrix} (3) The analytical solution of ( 3 ) yields: R=\frac{v^{\prime}i^{\prime\prime\prime}-i^{\prime\prime}v^{\prime\prime}}{i^{\prime}i^{\prime\prime\prime}-(i^{\prime\prime})^{2}}\qquad L=\frac{i^{\prime}v^{\prime\prime}-v^{\prime}i^{\prime\prime}}{i^{\prime}i^{\prime\prime\prime}-(i^{\prime\prime})^{2}} (4) Equation ( 4 ) is identical to equation (17) in [ 8 ] , where it was rigorously derived using GA. A more detailed model with a capacitor in series can also be obtained by introducing a third derivative. This extension can only be computed under nonsinusoidal voltage supply, which is a common condition in real applications. For mathematical convenience, the elastance S is used instead of the capacitance itself in the KVL expression, resulting in the following formulation: \displaystyle v^{\prime} \displaystyle=Si+Ri^{\prime}+Li^{\prime\prime} (5) \displaystyle v^{\prime\prime} \displaystyle=Si^{\prime}+Ri^{\prime\prime}+Li^{\prime\prime\prime} \displaystyle v^{\prime\prime\prime} \displaystyle=Si^{\prime\prime}+Ri^{\prime\prime\prime}+Li^{\prime\prime\prime\prime} then, we can build the following set of equations: \begin{bmatrix}i&i^{\prime}&i^{\prime\prime}\\ i^{\prime}&i^{\prime\prime}&i^{\prime\prime\prime}\\ i^{\prime\prime}&i^{\prime\prime\prime}&i^{\prime\prime\prime\prime}\end{bmatrix}\begin{bmatrix}S\\ R\\ L\end{bmatrix}=\begin{bmatrix}v^{\prime}\\ v^{\prime\prime}\\ v^{\prime\prime\prime}\end{bmatrix} (6) Equation ( 6 ) can be solved analytically yielding equation (25) of [ 8 ] obtained with GA. II-B Parallel Equivalent Circuit A similar process is applied to the parallel circuit by using KCL. For a more straightforward derivation, it is convenient to use conductance G and compliance \Gamma . The resulting expressions for the parameter identification of equivalent circuits with two and three elements are: \begin{bmatrix}v^{\prime}&v^{\prime\prime}\\ v^{\prime\prime}&v^{\prime\prime\prime}\end{bmatrix}\begin{bmatrix}G\\ \Gamma\end{bmatrix}=\begin{bmatrix}i^{\prime}\\ i^{\prime\prime}\end{bmatrix} (7) \begin{bmatrix}v&v^{\prime}&v^{\prime\prime}\\ v^{\prime}&v^{\prime\prime}&v^{\prime\prime\prime}\\ v^{\prime\prime}&v^{\prime\prime\prime}&v^{\prime\prime\prime\prime}\end{bmatrix}\begin{bmatrix}C\\ G\\ \Gamma\end{bmatrix}=\begin{bmatrix}i^{\prime}\\ i^{\prime\prime}\\ i^{\prime\prime\prime}\end{bmatrix} (8) The analytical solution of ( 7 ) and ( 8 ) yields the expressions derived in