Implicit Neural Representation-Based MRI Reconstruction Method with sensitivity map Constraints

2025

Read Implicit Neural Representation-Based MRI Reconstruction Method with sensitivity map Constraints (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-06043.txt.

Introduction

Rao and co-authors sharpen fast MRI reconstruction by also policing the maps that say how each coil in the scanner hears the body. Their 2025 paper uses implicit neural representation, a method that fits a small network to one scan at a time, so no library of full scans is needed for training. Speed asks for sparse data, which makes the coil maps hard to pin.

Most such methods only keep the image itself smooth, and let the coil maps drift. Their network, INR-CRISTAL, adds a smoothness rule for the maps, which suits their known soft shape. In tests the maps came out cleaner with fewer ghosts, and the rebuilt images kept fine structure better while shedding artifacts.

Catalog record

YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE40 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2506-06043

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Implicit Neural Representation-Based MRI Reconstruction Method with sensitivity map Constraints Abstract Magnetic Resonance Imaging (MRI) is a widely utilized diagnostic tool in clinical settings, but its application is limited by the relatively long acquisition time. As a result, fast MRI reconstruction has become a significant area of research. In recent years, Implicit Neural Representation (INR), as a scan-specific method, has demonstrated outstanding performance in fast MRI reconstruction without fully-sampled images for training. High acceleration reconstruction poses a challenging problem, and a key component in achieving high-quality reconstruction with much few data is the accurate estimation of coil sensitivity maps. However, most INR-based methods apply regularization constraints solely to the generated images, while overlooking the characteristics of the coil sensitivity maps. To handle this, this work proposes a joint coil sensitivity map and image estimation network, termed INR-CRISTAL. The proposed INR-CRISTAL introduces an extra sensitivity map regularization in the INR networks to make use of the smooth characteristics of the sensitivity maps. Experimental results show that INR-CRISTAL provides more accurate coil sensitivity estimates with fewer artifacts, and delivers superior reconstruction performance in terms of artifact removal and structure preservation. Moreover, INR-CRISTAL demonstrates stronger robustness to automatic calibration signals and the acceleration rate compared to existing methods. I Introduction Magnetic Resonance Imaging (MRI), a widely used diagnostic tool in clinical medicine [ 1 ] , often requires lengthy scanning procedures, which can cause patient discomfort. Moreover, prolonged scans increase the risk of image distortion due to natural body movements such as heartbeat and respiration. Consequently, accelerating MRI through undersampling and reconstruction has become a key research focus in the field [ 2 ] , [ 3 ] . Parallel imaging (PI) [ 4 ] , [ 5 ] , [ 6 ] has been widely used in commercial MRI scanners for acceleration. The PI reconstruction methods can be broadly categorized into image domain [ 5 ] , [ 7 ] , [ 8 ] , and k-space reconstruction approaches [ 6 ] , [ 9 ] , [ 10 ] . The former relies on pre-calculated coil sensitivity maps [ 11 ] , [ 12 ] , and the latter learns kernels for reconstruction from the auto-calibration signal (ACS) [ 13 ] . Compressed sensing further accelerates MRI acquisition by non-uniform sampling and imposing appropriate constraints on the reconstruction models, such as image sparsity [ 14 ] , [ 15 ] , low rankness [ 16 ] , [ 17 ] , [ 18 ] , [ 19 ] , [ 20 ] , or a combination of both [ 21 ] , [ 22 ] . With the advancement of deep learning, fast imaging techniques based on these methods have demonstrated considerable promise, offering improvements in both reconstruction speed and image quality compared to traditional optimization approaches [ 23 ] , [ 24 ] , [ 25 ] , [ 26 ] , [ 27 ] . Nevertheless, most deep learning models necessitate large volumes of fully sampled prior data for pre-training, leading to extended training times [ 28 ] , [ 29 ] , [ 30 ] , [ 31 ] , and are also challenged by issues of data generalization when there is a mismatch between the training and inference data distributions. In recent years, implicit neural representation (INR) has garnered significant attention as a self-supervised approach [ 32 ] , [ 33 ] , [ 34 ] , [ 35 ] , [ 36 ] , [ 37 ] , [ 38 ] , [ 39 ] . Unlike traditional discrete representations that store signal values or features explicitly, INR defines a continuous generator function that maps input coordinates directly to the corresponding values in the output space. Typically, this function is parameterized by a fully connected neural network, most commonly multi-layer perceptrons (MLPs), enabling the representation of complex signals such as images, videos, and even 3D scenes with high fidelity and resolution. Owing to their resolution independence, memory efficiency, and compatibility with gradient-based optimization, INR-based models have shown remarkable promise in a variety of tasks, including image reconstruction, novel view synthesis, and medical image modeling. In the field of MRI reconstruction, INR has been applied in various imaging scenarios, yielding promising results [ 33 ] , [ 38 ] , [ 39 ] , [ 40 ] , [ 41 ] , [ 42 ] , [ 43 ] . Implicit neural representation learning with prior embedding (NeRP) [ 33 ] exploited INR to map image coordinates to corresponding intensity values for MRI reconstruction. However, NeRP requires a fully sampled image prior of the same subject for pre-training. To address this issue, Feng et al. proposed a self-supervised implicit representation for joint coil sensitivity and image estimation (IMJENSE) [ 38 ] , which jointly estimates coil sensitivities and MRI images. In IMJENSE, the image was generated by MLPs, and the sensitivity map was parameterized by polynomials. Expanding on IMJENSE, CineJENSE [ 39 ] replaced the polynomials for coil sensitivity estimation with another INR network and extended to cardiac MRI reconstruction. In addition, INR and its varieties have been applied to different MRI reconstruction problems such as dynamic MRI, mapping, etc [ 40 ] , [ 41 ] , [ 42 ] , [ 43 ] . However, few INR-based methods consider leveraging the smoothness of the coil sensitivity maps and imposing constraints on them during the training process. Many studies have shown that accurate sensitivity estimation is essential for high-quality MRI reconstruction using image domain PI methods [ 7 ] , [ 11 ] , [ 12 ] . It has been shown that incorporating appropriate constraints on sensitivity maps can facilitate its accurate estimation and further reduce the error of reconstructed images, in optimization-based reconstruction [ 7 ] , [ 44 ] , and supervised deep learning reconstruction [ 45 ] . Although the polynomial sensitivity map modeling of IMJENSE can be regarded as an implicit smooth constraint, the sensitivity maps generated by IMJENSE have expanded support to the actual image support, with little high-frequency detail information, resulting in suboptimal results (Fig. 1 (b)). Coil sensitivity maps could be successfully modeled by MLPs in CineJENSE (which is reduced to two dimensions), providing sensitivity predictions closer to the ground truth. However, when the ACS data is collected in minimal quantities, CineJENSE fails to produce accurate sensitivity maps with severe artifacts (red arrows in Fig. 1 (c)), finally leading to degraded image quality. Therefore, an INR-based method with coil sensitivity regularization image and sensitivity estimation algorithm (INR-CRISTAL) is proposed for PI reconstruction in this work. Two MLPs estimated the composite MRI image and corresponding coil sensitivity maps, respectively. The proposed method leverages the smooth characteristics of the sensitivity map by introducing an extra sensitivity map regularization in the INR networks. This regularization term on sensitivity can be flexibly modeled according to different applications. We discussed the effects of different regularization terms on reconstruction results and provided recommended regularization to obtain promising reconstructions. Experimental results demonstrate that the proposed INR-CRISTAL outperforms the state-of-the-art optimization-based or scan-specific reconstruction methods regarding aliasing artifact suppression. Moreover, the proposed INR-CRISTAL exhibits robustness to the ACS and reduction factor (R). The INR-CRISTAL still achieves

Read the complete text