Impact of common modes correlations and time sampling on the total noise of a H2RG near-IR detector
Bogna Kubik a, Remi Barbier a, Alain Castera a, Eric Chabanat a, Sylvain Ferriol a, Gerard Smadja a a Université de Lyon, Université Lyon 1, Lyon F-69003, France CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622, France · 2025
Read Impact of common modes correlations and time sampling on the total noise of a H2RG near-IR detector by Bogna Kubik a, Remi Barbier a, Alain Castera a, Eric Chabanat a, Sylvain Ferriol a, Gerard Smadja a a Université de Lyon, Université Lyon 1, Lyon F-69003, France CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622, France (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-04995.txt.
Introduction
Bogna Kubik and co-authors study how to cut readout noise in a near infrared detector bound for a space mission. Their 2025 paper deals with a 2K by 2K mercury cadmium telluride array. A similar detector will fly on a European space telescope's infrared instrument. The noise of concern includes a slow drift type known as 1/f noise. Reference pixels inside the array can help remove shared noise patterns.
Several methods for subtracting those shared patterns are defined and compared. Used well, the references cut readout noise by sixty percent. A predictive model of the drift noise is also built from its frequency spectrum. It matched data across a wide range of sampling rates. With such a model, custom noise figures for each sampling choice are no longer needed, the authors say.
Catalog record
| CREATOR | Bogna Kubik a, Remi Barbier a, Alain Castera a, Eric Chabanat a, Sylvain Ferriol a, Gerard Smadja a a Université de Lyon, Université Lyon 1, Lyon F-69003, France CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622, France |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 34 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2506-04995
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Impact of common modes correlations and time sampling on the total noise of a H2RG near-IR detector Bogna Kubik a, Remi Barbier a, Alain Castera a, Eric Chabanat a, Sylvain Ferriol a, Gerard Smadja a a Université de Lyon, Université Lyon 1, Lyon F-69003, France CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622, France Abstract We present the readout noise reduction methods and the 1/f noise response of an 2K × \times 2K HgCdTe detector similar to the detectors that will be used in the Near Infrared Spectrometer Photometer - one of the instruments of the future ESA mission named Euclid. Various algorithms of common modes subtraction are defined and compared. We show that the readout noise can be lowered by 60% using properly the references provided within the array. A predictive model of the 1/f noise with a given frequency power spectrum is defined and compared to data taken in a wide range of sampling frequencies. In view of this model the definition of ad-hoc readout noises for different sampling can be avoided. keywords HgCdTe detectors, H2RG, common modes, reference pixels, 1/f noise, temporal noise, frequency power spectrum, infrared astronomy † † authorinfo: Further author information: (Send correspondence to B. Kubik) B.Kubik: E-mail: [email protected], Telephone: +33 4 72 43 10 74 G.Smadja: E-mail: [email protected], Telephone: +33 4 72 44 83 18 E.Chabanat: E-mail: [email protected], Telephone: +33 4 72 43 27 51 S.Ferriol: E-mail: [email protected], Telephone: +33 4 72 44 82 88 A.Castera: E-mail: [email protected], Telephone: +33 4 72 44 84 29 R.Barbier: E-mail: [email protected], Telephone: +33 4 72 43 12 22 1 INTRODUCTION Complementary Metal-Oxide Semiconductor (CMOS) sensors have become a competitive astronomical ground- and space-based detector solution. In the near-infrared spectral range from 1 to 12 \mu m, two semiconductor materials are competing, namely InSb and HgCdTe grown by liquid phase epitaxy or molecular beam epitaxy on Al, Si or CdZnTe substrates. This paper will focus on HgCdTe arrays grown on CdZnTe substrates. Hybrid CMOS sensors have a flexible readout structure that allows a group of pixels on the array to be read out at any time without disturbing or reading out the rest of the array. In addition to the flexible readout, CMOS sensors are naturally less sensitive to radiation than more traditional detectors like Charge Coupled Devices (CCDs), since damage to one pixel in the array does not adversely affect subsequent pixels in a row or column of the array. This inherent radiation hardness is particularly appealing for space-based applications. An infrared hybrid active pixel sensor is composed of two components, a diode array fabricated with narrow band gap semiconductor material sensitive at infrared wavelengths and a silicon CMOS readout multiplexer with a buffer source follower, a reset switch and addressing switches placed in the unit cell of each pixel. The two components, the infrared diode array and the Si CMOS multiplexer are hybridized with indium bumps making the electrical interconnections for each pixel between the infrared diode and the unit cell of the silicon multiplexer. We present here an analysis of the noise of a substrate-removed HAWAII-2RG (HgCdTe Astronomy Wide Area Infrared Imager with 2K x 2K resolution, Reference pixels and Guide mode) array from Teledyne Imaging Sensors (TIS) with a cut-off wavelength of 2.5 \mu m and an operational temperature of 90K. The array is driven and digitized by the SIDECAR ASIC chip inside the dewar. The firmware used during acquisitions is the one delivered with the SIDECAR Acquisition Module (SAM Board development kit Software 3.0) provided by the same company [ 1 ] . In addition to the common modes investigations through a study of the spatial properties of the noise we implement here a time analysis in each pixel which provides a direct evidence for the 1/f contributions originating from the electronic components at the pixel and readout levels, namely from the PN junction and from the source follower of the multiplexer. The two approaches are complementary, as the spatial analysis is best suited for a characterization of common modes and has led us to propositions for the improvement of the standard acquisition schemes, whilst the time analysis helps to clarify the role of the sampling frequency and has a predictive power of the readout noise in different time sampling. The work we present in this paper was initiated in the context of the Euclid satellite project. The HgCdTe detectors, usually H1RG 1K \times 1K, however has been used extensively in numerous focal plane arrays of ground and space telescopes. We shall only quote a small subset of ground implementations in the Wide-field Infrared Survey Explorer (WISE), Very Large Telescope (VLT), Wide Field Camera 3 (WFC3) of the Hubble Space Telescope (HST). The H2RG-SIDECAR detector system is also planned to be used in the James Webb Space Telescope (JWST). 2 SETUP The H2RG detector is designed to operate in a number of different modes. We operate with the 100 kHz (slow) pixel rate which is designed to ensure the lowest readout noise. The H2RG detector can be read using 1, 4 or 32 parallel outputs. The former uses the lowest power, but the latter provides the highest frame rates. For the spatial noise analysis we set the 32-output readout mode. With overheads, the acquisition firmware yields a minimum exposure time of 1.47 seconds, or a frame rate of 0.68 Hz, when using 32 channels. The flexible readout structure allows a sub-array of pixels to be read out at any time, however this mode is only available using one output. In order to achieve very high frame rates for the temporal noise analysis we chose a sub-array of pixels of dimension 8 \times 64 pixels. The 100 kHz pixel rate and some overheads lead to a 7.12 msec minimal exposure time (140 Hz frame rate). Multiple Accumulated (MACC) sampling and Up-The-Ramp (UTR) sampling are both available. The MACC sampling consist in reading N groups of n frames separated with n_{d} dropped frames. The n frames in each group are then averaged to form a single coadded frame. In the UTR mode frames are readout continuously during the whole exposure time, without any drops nor coadding. We choose to operate in the UTR mode storing all the frames in the memory and to construct a MACC mode subsequently during the data analysis. We checked that the noise properties are the same in both, the MACC acquisitions programmed directly in the ASIC or the MACC mode constructed in the offline analysis. Our choice of operating only with the UTR acquisitions is driven by the time economy since with one UTR exposure we can test several MACC modes with equivalent exposure time. Numerous tests were carried out on engineering-grade detector to develop our software (DAS v.1.0 [ 11 ] and Selene v.1.0 [ 12 ] ) and to characterize the performance of the H2RG-GH456-IR25-GLS SCA. The measurements described below were carried out in a dedicated setup built to evaluate the H2RG detectors in the IPNL laboratory facility. 3 COMMON MODE CORRECTION USING REFERENCE PIXELS 3.1 Reference signals The sensitivity of infrared detectors is limited by photon shot noise, dark current and read noise. The dark current can be lowered down below the natural background level