Optimization of the multiple sampling and signal extraction in non-destructive exposures

Bogna Kubik \supscr a, Remi Barbier \supscr a, Alain Castera \supscr a, Eric Chabanat \supscr a, Sylvain Ferriol \supscr a, Gerard Smadja \supscr a · 2025

Read Optimization of the multiple sampling and signal extraction in non-destructive exposures by Bogna Kubik \supscr a, Remi Barbier \supscr a, Alain Castera \supscr a, Eric Chabanat \supscr a, Sylvain Ferriol \supscr a, Gerard Smadja \supscr a (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-04904.txt.

Introduction

Astronomy cameras can read the same exposure many times without destroying the signal, and how those readings are combined shapes the final quality. Kubik and co-authors refine that math in this 2025 paper. They derive the full covariance formulas needed to treat the links between readings honestly in signal fitting, extending earlier published results.

Straight-line fits with their matrices reach a much better signal-to-noise ratio once the light flow passes a threshold, above all in long spectroscopic exposures. Using every frame sampled during the exposure proves best at all light levels. At low light, frames can be grouped freely; at higher light, grouping them together should be avoided. The work speaks to instrument teams who squeeze faint signals from the sky.

Catalog record

CREATORBogna Kubik \supscr a, Remi Barbier \supscr a, Alain Castera \supscr a, Eric Chabanat \supscr a, Sylvain Ferriol \supscr a, Gerard Smadja \supscr a
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE27 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2506-04904

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Optimization of the multiple sampling and signal extraction in non-destructive exposures Bogna Kubik \supscr a, Remi Barbier \supscr a, Alain Castera \supscr a, Eric Chabanat \supscr a, Sylvain Ferriol \supscr a, Gerard Smadja \supscr a Abstract We derive the full covariance matrix formulae are derived for proper treatment of correlations in signal fitting procedures, extending the results from previous publications. The straight line fits performed with these matrices demonstrate that a significantly higher signal to noise is obtained when the fluence exceeds 1 e − e^{-} /sec/pix in particular in long (several hundreds of seconds) spectroscopic exposures. The improvement arising from the covariance matrix is particularly strong for the initial intercept of the fit at t=0, a quantity which provides a useful redundancy to cross check the signal quality. We demonstrate that the mode that maximizes the signal to noise ratio in all ranges of fluxes studied in this paper is the one that uses all the frames sampled during the exposure. While at low flux there is no restriction on the organization of frames within groups for fluxes lower than 1 e − e^{-} /sec/pix, for fluxes exceeding this value the coadding of frames shell be avoided. keywords HgCdTe detectors, H2RG, signal processing, covariance matrix, noise correlations Address all correspondence to : Bogna Kubik, Institut de Physique Nucléaire de Lyon, 4 rue Enrico Fermi, Villeurbanne F-69622, France Tel: +33 4 72 44 58 52; E-mail: \linkable [email protected] 1 Introduction Up to now, many efforts have been made to minimize the readout noise of the integrating arrays in low-background experiments, such as spectroscopic imaging, where the readout noise of the array may remain the dominant source of noise even with integration time as long as of tens minutes. However, few studies have given attention to methods of signal fitting, as a simple least square fit provides a good signal estimate and an acceptable precision on the flux. The correlations in Poisson and readout noise that are intrinsic to the non-destructive readout of integrating arrays have been neglected, leading to a wrong estimation of signal noise. If a very stringent error budget is required it is crucial to take these correlations into account in the fitting procedure. In [ 1 ] an algorithm of processing the array of pixels by averaging multiple reads was proposed to lower the readout noise as compared to the single read. The performances of Fowler sampling, correlated double sampling (CDS) and line fitting were studied in [ 2 ] . The statement was made that both, Fowler sampling and line fitting are superior to the CDS in the readout noise limited performance. Moreover, the line fitting is superior to the optimal Fowler sampling by about 6%. In the background limited regime, where the detector noise is dominated by the shot noise of the incident photons, the optimal signal to noise ratio is achieved in the CDS sampling. The variance of the integrated signal from data sampled continuously up the ramp was derived in [ 3 ] and [ 4 ] . This noise model includes readout noise and shot noise on the integrated flux, taking into account the correlations between the multiple nondestructive reads. Three main issues are addressed in this study. First we focus on the method of signal fits in different regimes of incident flux. We derive the formulae of covariance matrices for groups and group differences that take into account the correlations in readout noise and in Poisson noise arising from multiple reads during a single exposure. Next, we introduce these matrices into the fitting procedure and show that taking into account these correlations we can achieve a higher signal to noise ratio than with the line fitting. Finally, taking advantage of the possibility of nondestructive reads and the fit with the covariance matrix, we find out the optimal readout mode independently on the flux regime. The equations for noise correlations in the MACC readout scheme are derived and compared to a simulated values in section 2 . The procedure giving the optimal signal to noise ratio are presented in section 3 while the optimal readout parameters of the MACC acquisitions are found in section 4 . 2 Linear fit of data with correlated errors Infrared astronomy has been revolutionized by the introduction of two-dimensional array detectors, which have increased the efficiency of telescopes more than a thousandfold for direct imaging. The situation is quite different for low-background experiments, such as narrow band imaging or spectroscopy, where the readout noise of the array detectors may remain the dominant source of noise even in integrations of tens of minutes duration. Moreover, the possibility of non-destructive reads of the integrating pixels allowed to lower the readout noise by applying the procedure known as frames coadding (see [ 1 ] , [ 2 ] , [ 3 ] and [ 4 ] for definitions). It was already noticed in [ 5 ] that the best calculation of slope and y -intercept must use all information including correlated and uncorrelated errors. A fit with the covariance matrix of equally sampled data was presented. The frames were sampled up the ramp and were not averaged into groups. It was shown that the fit with covariance matrix provides higher signal to noise ratio than a simple equally weighted least square fit. In this section, we derive the general expression of noise correlations between groups and group differences in the ramp sampled with the Multiple Accumulated readout scheme and construct the covariance matrix C for line fitting and the matrix D for fitting of differences. The values on the diagonal of C and D are the uncertainties of the fitted points, whereas the off-diagonal elements are the covariances between the different samples in the ramp. The diagonal entries are not only simple sums of the readout noise and shot noise, which would be the case for a simple up the ramp sampling without coadding, but include the correlations in the shot noise after the coadding procedure. Moreover, if the data points were uncorrelated, then the off-diagonal matrix elements would be all zero. However, we do have correlated data in addition to correlations resulting from the coadding procedure: the shot noise is correlated in the line fitting while the readout noise correlates points in the difference fit. The real power of using matrix notation arises from the covariance matrix, as it includes information about the degree of correlation between samples. Furthermore, the slope and y -intercept uncertainties resulting from using this covariance matrix automatically take into account the correlated and uncorrelated errors, provided they are included in the covariance matrix. Another benefit of using matrix notation with a covariance matrix is that we can add other noise terms easily by calculating the appropriate covariance matrix - this would be the case of the 1/f noise which correlates all the groups in the ramp and should be incorporated into the covariance matrix to fit real data. It is however out of the scope of this paper and we leave this subject for later investigations. 2.1 UTR and MACC readout modes For most science observations, NIR detectors acquire up the ramp (UTR) sampled data at a constant frame cadence as presented in the

Read the complete text