Coupling models of resistive valves to muscle mechanics in cardiac fluid-structure interaction simulations

Michele Bucelli, Luca Dede’ · 2025

Read Coupling models of resistive valves to muscle mechanics in cardiac fluid-structure interaction simulations by Michele Bucelli, Luca Dede’ (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-03869.txt.

Introduction

Bucelli and Dede' couple resistive valve models to muscle mechanics in heart simulations, in a paper from twenty twenty-five. Simulating the full cardiac cycle needs faithful valve models. The resistive immersed surface method is efficient but ignores attachment forces. That omission breaks Newton's laws in fluid-structure interaction settings.

Distributed forces on the structure now model valve attachment to walls. The fix adds minimal cost through explicit time stepping. Idealized and realistic tests confirm physical consistency of the model. Other resistive valve models gain the same benefit. Heart chamber simulations can now include valves rigorously.

Catalog record

CREATORMichele Bucelli, Luca Dede’
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE58 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2506-03869

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Coupling models of resistive valves to muscle mechanics in cardiac fluid-structure interaction simulations Michele Bucelli, Luca Dede’ Abstract To accurately simulate all phases of the cardiac cycle, computational models of hemodynamics in heart chambers need to include a sufficiently faithful model of cardiac valves. This can be achieved efficiently through resistive methods, and the resistive immersed implicit surface (RIIS) model in particular [Fedele et al., BMMB, 2017]. However, the conventional RIIS model is not suited to fluid-structure interaction (FSI) simulations, since it neglects the reaction forces by which valves are attached to the cardiac walls, leading to models that are not consistent with Newton’s laws. In this paper, we propose an improvement to RIIS to overcome this limitation, by adding distributed forces acting on the structure to model the attachment of valves to the cardiac walls. The modification has a minimal computational overhead thanks to an explicit numerical discretization scheme. Numerical experiments in both idealized and realistic settings demonstrate the effectiveness of the proposed modification in ensuring the physical consistency of the model, thus allowing to apply RIIS and other resistive valve models in the context of FSI simulations. Keywords: fluid-structure interaction, cardiac modeling, valve modeling, resistive immersed implicit surface 1 Introduction The motion of cardiac valves, both native and prosthetic, is regulated by the complex and dynamic interplay of blood flow with the mechanics of valve leaflets. A physically detailed computational model of valves must be able to deal with large deformations, the effect of chordae tendineae, and the contact among valve leaflets themselves davey2024simulating , feng2024whole , oks2022fluid , zingaro2024advancing , johnson2021parameterization , terahara2022computational , caballero2018new , toma2017fluid , meschini2018flow , spuhler20183d , kronborg2025fluidstructure . These aspects, although crucial when focusing on valve dynamics or valvular dysfunctions, pose a significant challenge in terms of model calibration, complexity, and computational cost. As an alternative, it is possible to use valve models that are simplified, geometrically (e.g. using a planar representation of the valve), physically (by neglecting fluid-structure interaction), or both chnafa2014image , vedula2016effect , vellguth2018development . This is especially convenient for models that do not focus on the valves themselves, but only need to account for the macroscopic effect of the valves on the flow within heart chambers, such as the way their opening and closing determines heartbeat phases bucelli2023mathematical , or the large-scale jets and vortices caused by valve leaflets zingaro2022geometric , seo2014effect . Simplified models may be sufficiently accurate to capture these features, yet at a manageable complexity and cost. Many such models are based on a resistive approach, by which the equations for fluid flow are modified to penalize the mismatch between the fluid velocity and valve velocity in the proximity of the valve. This corresponds to modeling the valve as a porous medium with very low permeability daub2020replication . For example, valves are modeled in karabelas2022global through Navier-Stokes-Brinkman equations, assuming a planar geometry. The Resistive Immersed Surface method astorino2012robust , this2020augmented , ruz2024left represents valves as resistive surfaces, which are assumed to be conforming to the mesh used to discretize fluid equations. In both Navier-Stokes-Brinkman and Resistive Immersed Surface, the opening and closing of the valve may be modeled by varying the associated penalization coefficient (i.e. its permeability) over time. In this work, we consider the Resistive Immersed Implicit Surface method fedele2017patient , which relaxes the mesh-conformity constraint of Resistive Immersed Surface by implicitly representing valves through signed distance functions. This allows to represent the valve leaflets as they open and close, regardless of the underlying mesh. The Resistive Immersed Implicit Surface method was extensively applied to cardiovascular hemodynamics simulations bucelli2023mathematical , zingaro2022geometric , zingaro2023electromechanics , corti2022impact , duca2025computational , crugnola2025computational , pase2023parametric , zingaro2024comprehensive , fumagalli2025reduced , showcasing its effectiveness in supporting detailed and patient-specific fumagalli2020image , bennati2023image , bennati2023turbulent , renzi2025accurate , crispino2024cardiac computational models. However, in the specific context of models that include fluid-structure interaction between blood and the cardiac walls, the Resistive Immersed Implicit Surface method (and resistive methods in general) may lead to issues in the balance of forces. Indeed, resistive surfaces exert a force on the fluid, to enforce the no-slip condition in proximity of the valve. In real hearts, this force is sustained by the attachment of valves to the walls, through either the chordae tendineae or the valve annuli. By simply applying the Resistive Immersed Implicit Surface method in its original form, this is neglected, which leads to a force imbalance and possibly to an unphysical behavior of the fluid-structure interaction system as a whole. This can be compensated through an ad-hoc calibration of other parameters, most notably the boundary conditions on the mechanics model, as done in bucelli2023mathematical . However, this approach lacks in physical soundness: the application of standard Resistive Immersed Implicit Surface in the fluid-structure interaction context leads to models that do not satisfy Newton’s laws. In this paper, we propose an improvement to the Resistive Immersed Implicit Surface method for fluid-structure interaction that accounts for the forces keeping the valves attached to the cardiac walls. After deriving an expression for these forces, we demonstrate through numerical experiments how neglecting them may lead to unphysical displacements, and how the proposed modification eliminates this issue. We remark that, with minor modifications, the proposed method can be extended to other resistive valve models, which may face the same issue when combined with fluid-structure interaction simulations. The remainder of this paper is structured as follows. In Section 2 , we present the mathematical models used for cardiac fluid-structure interaction, introduce the modifications for coupling resistive valves to solid mechanics, and discuss numerical discretization. Section 3 illustrates the properties of the proposed modification through numerical experiments. Finally, Section 4 draws some conclusive remarks. 2 Models and methods This section describes the modeling and discretization framework employed for cardiac fluid-structure interaction simulations, and presents the approach proposed in this work to couple resistive valves and muscular mechanics. 2.1 Cardiac fluid-structure interaction modeling Let t\in(0,T) denote the independent time variable, with T>0 . Let \Omega\subset\mathbb{R}^{3} be an open set, moving over time, representing the volume occupied by a beating heart. We partition \Omega into two subsets, \Omega_{\text{f}} and \Omega_{\text{s}} , representing the volume occupied by the blood inside the heart cavities and by the cardiac walls, respectively. Notice that the set \Omega_{\text{s}} does not include the cardiac valve leaflets, which are instead accounted for through a resistive approach, and are thus immersed in \Omega_{\text{f}} , as detailed below. Let \Sigma=\partial\Omega_{\text{f}}\cap\partial\Omega_{\text{s}} denote the fluid-solid interface. To track the deformation of the domain in time, we introduce the fixed reference domain \widehat{\Omega}\subset\mathbb{R}^{3} , as well as its subsets \widehat{\Omega}_{\text{f}} and \widehat{\Omega}_{\text{s}} . The current domains \Omega_{\text{f}} and \Omega_{\text{s}} are related to the reference domains through the continuous maps bucelli2023mathematical \displaystyle\boldsymbol{\psi}_{\text{f}}:\widehat{\Omega}_{\text{f}}\times(0,T)\to\Omega_{\text{f}}\;, \displaystyle\boldsymbol{\psi}_{\text{s}}:\widehat{\Omega}_{\text{s}}\times(0,T)\to\Omega_{\text{s}}\;. Henceforth, we shall use a hat to denote functions and sets in the reference configuration, without a hat their counterparts mapped onto the current configuration, and vice versa. We consider an fluid-structure interaction model of the displacement of the cardiac walls and the blood flow bucelli2023mathematical , bucelli2022partitioned , based on the arbitrary Lagrangian-Eulerian formulation of incompressible Navier-Stokes equations donea1982arbitrary , hughes1981lagrangian and on a hyperelastic model for muscular mechanics, including active stress regazzoni2022cardiac . The model features the following unknowns:

Read the complete text