Prediction of the SVOM MXT camera end of life spectral performance based on proton irradiation results Journal: Nuclear instrumentation and methods in physics research, A
Clara Plasse, Diego Götz, Aline Meuris, Miguel Fernandez Moita, Philippe Ferrando, Leo Favier, Francesco Ceraudo · 2025
Read Prediction of the SVOM MXT camera end of life spectral performance based on proton irradiation results Journal: Nuclear instrumentation and methods in physics research, A by Clara Plasse, Diego Götz, Aline Meuris, Miguel Fernandez Moita, Philippe Ferrando, Leo Favier, Francesco Ceraudo (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2506-02271.txt.
Introduction
Clara Plasse and co-authors forecast how radiation will wear down a space telescope camera, in a 2025 paper. The camera flies on SVOM, a Chinese-French satellite launched in 2024 to catch gamma-ray bursts. Its X-ray detector crosses a harsh radiation zone over the South Atlantic on each orbit. Protons there slowly degrade the sensor's spectral sharpness.
A spare flight camera was blasted with protons at a cyclotron to mimic years in orbit. It was then measured at a synchrotron beamline and with a lab X-ray source. Key sharpness indicators show how much quality fades by mission end. The forecast helps the team plan settings that hold performance for the whole flight. Similar small missions can reuse the approach.
Catalog record
| CREATOR | Clara Plasse, Diego Götz, Aline Meuris, Miguel Fernandez Moita, Philippe Ferrando, Leo Favier, Francesco Ceraudo |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 53 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2506-02271
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Prediction of the SVOM MXT camera end of life spectral performance based on proton irradiation results Journal: Nuclear instrumentation and methods in physics research, A Clara Plasse, Diego Götz, Aline Meuris, Miguel Fernandez Moita, Philippe Ferrando, Leo Favier, Francesco Ceraudo Abstract SVOM, the Space-based Variable astronomical Object Monitor, launched on June 22 nd 2024, is a Chinese-French mission focused on exploring the brightest phenomena in the cosmos – Gamma-Ray Bursts. Among the four instruments on board is the Micro-channel X-ray Telescope (MXT). The MXT camera features a 256 × \times 256 pixel pnCCD detector to perform X-ray imaging and spectroscopy in the 0.2–10 keV energy range. Cruising in a low-Earth orbit ( ∼ \sim 600 km) that crosses the South Atlantic Anomaly, the MXT focal plane is exposed to radiation, primarily protons, that will lead to performance degradation over time. The challenge for MXT, and possibly for future missions with similar mass and mechanical constraints, is to maintain spectral performance all along the mission duration. To assess the expected radiation-induced performance degradation, a spare flight model of MXT focal plane underwent an irradiation campaign with 50 MeV protons at the Arronax cyclotron facility in June 2022. Then, the proton irradiated spare model was characterized in detail at the X-ray Metrology beamline of the SOLEIL Synchrotron facility in June 2023, as well as with a laboratory X-ray fluorescence source. We find through the evaluation of key indicators of performance such as the charge transfer inefficiency (CTI) and the low energy threshold, that MXT will remain compliant to its requirements over the SVOM mission lifetime. We also report an unexpected effect of proton irradiation that is the inversion of the trend of CTI with energy, recovered with two different sources illuminating the detector, and never reported in literature so far. 1 Introduction SVOM (Space-based Variable astronomical Object Monitor) is a space mission aimed at studying Gamma-Ray Bursts (GRBs) and other rapid, high-energy transient events across multiple wavelengths ( Atteia et al. 2022 , Wei et al. 2016 ). It was launched in June 2024 on a circular low Earth orbit (h \sim 600 km) with an inclination of about 29 ∘ . Along its low-Earth orbit, due to South Atlantic Anomaly crossings, the SVOM satellite and its instruments is subject to radiation damage, primarily from proton interactions. In the case of The Micro-channel X-ray Telescope (MXT), one of the four main instrument aboard, the proton irradiation creates defects in the detector crystalline structure, expected to cause performance degradation. The MXT camera is composed of the Focal Plane Assembly (FPA), a Front-End Electronics (FEE) assembly and a Calibration Wheel Assembly to perform X-ray imaging and spectroscopy in the 0.2–10 keV energy range, as illustrated in Figure 1 . The calibration wheel features four positions: (i) two open position for sky observations, (ii) a calibration position utilizing a radioactive 55 Fe source that fully illuminates the detector, and (iii) a closed position equipped with a 10 mm thick copper shutter for regular transitions through the South Atlantic Anomaly. The core of the camera is a pnCCD (450 \mu m-thick fully depleted charge coupled detector made of pn junctions using the sidewards depletion principle) with a 256 \times 256 pixel imaging area for photon integration and a frame store area for the image readout. This imaging detector, optimized for high resolution X-ray spectroscopy, was designed, produced and first characterized by the Max-Planck-Institute for Extraterrestrian Physics (MPE) in the context of the DUO mission ( Meidinger et al. 2005 ) . It has been implemented in the context of the SVOM mission, taking advantage of the last generation of front-end CAMEX ASICs designed and being successfully operated in the eROSITA instrument on board the SRG mission ( Meidinger et al. 2008 ) , and by developing a dedicated readout electronics system compatible with the exportation rules to China. The operating temperature of -65^{\circ} C of the detector is a compromise between the cooling capability for this small satellite on a low-Earth orbit (an intrinsically highly variable thermal environment) and the necessity to limit the dark current of the detector. Previous missions with the same detector technology operate the pnCCD at significantly colder temperatures: -90^{\circ} C for EPIC/XMM-Newton launched in 1999 ( Jansen et al. 2001 ) and for FXT/Einstein Probe launched in 2023 ( Yuan et al. 2022 ) , and -80^{\circ} C for eROSITA/SRG launched in 2019 ( Sunyaev, R. et al. 2021 ) . The capability to maintain the required spectral performance along the mission lifetime is consequently a serious concern and challenge for SVOM and for future missions with similar orbits, power and mass resources. The target performance is an energy resolution better than 80 eV FWHM at 1.5 keV at beginning of life and better than 200 eV FWHM (+250 %) after the 3 years of nominal mission. Figure 1: Focal plane assembly (FPA) of MXT camera. A ceramic board equipped with a pnCCD (1) and 2 Camex ASICs (2) is mounted in a proton shielding (3) and the flex lead (4) is connected to the warm front-end electronics (5). To monitor the spectral evolution in flight, the calibration strategy relies on the observation of two types of sources: an internal 55 Fe radioactive source assembled to a filter wheel, and astrophysical sources. Astrophysical sources, typically Supernova Remnants (SNRs) are stable in flux and emit lines at numerous energies across the X-ray domain. However, due to the SNRs lower flux (wrt. the internal source), they require longer exposure times, which could potentially conflict with the mission observation schedule. On the contrary, the calibration source can be used regularly, e.g. during each Earth occultations, fully illuminating the detector and emitting two spectral lines around \sim 6 keV. Given that the maximum sensitivity of MXT is around 1 keV, very precise calibration and a good understanding of the detector response at all energies are crucial to correctly extrapolate the regular 55 Fe measurements over the whole energy range. This will be particularly necessary for an ageing MXT camera, as the spectral response will deteriorate over time and could even affect the instrument’s source location capability, if the low-energy threshold increases excessively. For a complete description of the MXT telescope, see Götz et al. 2023 . The paper is organized as follows: we describe the methodology for the performance degradation assessment, including the campaigns carried out for the irradiation and characterization of MXT focal plane, and the data analysis techniques employed to forecast performance throughout the mission lifespan in Section 2 . Our empirical findings and interpretations focused on the effect of irradiation are outlined in Section 3 . Finally, we discuss these results and review the expected and unexpected effects of the proton irradiation in Section 4 . 2 Experimental setup and performance characterisation 2.1 The MXT camera The detector board shown in Figure 1 , made of aluminium oxide ( Al_{2}O_{3} ), holds the pnCCD, the two CAMEX ASICs and passive parts for voltage filtering. It is glued on a copper-molybdenum mechanical structure which protects the frame store area from X-rays and which is thermally coupled to the active cooling system. The main features of MXT camera are listed in Table 1 .