A highly sensitive SF 6 -based leak test system for JUNO 3-inch PMT underwater electronics boxes

Ziliang Chu, Diru Wu, Miao He, Jilei Xu, Xiaoping Jing, Jian Wang · 2025

Read A highly sensitive SF 6 -based leak test system for JUNO 3-inch PMT underwater electronics boxes by Ziliang Chu, Diru Wu, Miao He, Jilei Xu, Xiaoping Jing, Jian Wang (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-24142.txt.

Description

Ziliang Chu and five co-authors build a leak test system for underwater electronics boxes in a neutrino observatory, in a paper from 2025. The Jiangmen observatory holds tens of thousands of light sensors whose electronics sit in two hundred steel boxes underwater. Each box must be proven watertight before installation, and helium testing was ruled out because helium seeps through sensor glass.

Their system gathers sulfur hexafluoride gas leaking from a box over hours and sniffs it at extreme sensitivity. The limit beat the required threshold. The test caught a few leaking boxes, which were replaced before the array went underwater.

Catalog record

CREATORZiliang Chu, Diru Wu, Miao He, Jilei Xu, Xiaoping Jing, Jian Wang
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE45 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-24142

Browse the full library · About the Tower of Babel