Computerized Modeling of Electrophysiology and Pathoelectrophysiology of the Atria –- How Much Detail is Needed?

Olaf Dössel \orcidID 0000-0003-4551-7970 and Axel Loewe \orcidID 0000-0002-2487-4744 · 2025

Read Computerized Modeling of Electrophysiology and Pathoelectrophysiology of the Atria –- How Much Detail is Needed? by Olaf Dössel \orcidID 0000-0003-4551-7970 and Axel Loewe \orcidID 0000-0002-2487-4744 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-23717.txt.

Introduction

Computer models of the heart's upper chambers help doctors plan treatment for racing, uneven heartbeats. Olaf Dossel and Axel Loewe review those models in a 2025 article and ask a pointed question: how much detail does a model need before its results can be trusted? Too little detail misleads, and too much wastes computing power.

The review walks through atrial modeling from single cells to the whole chamber pair. It weighs how shape, fiber direction, wall thickness, and uneven conduction change the outcome. It compares full 3D models with thinner bilayer and surface versions, and covers scarred tissue, testing, and validation. The end use is treatment planning: models tuned to one patient, or built from groups, to guide ablation, the procedure that burns small spots to block faulty signals.

Catalog record

CREATOROlaf Dössel \orcidID 0000-0003-4551-7970 and Axel Loewe \orcidID 0000-0002-2487-4744
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE41 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-23717

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Computerized Modeling of Electrophysiology and Pathoelectrophysiology of the Atria –- How Much Detail is Needed? Olaf Dössel \orcidID 0000-0003-4551-7970 and Axel Loewe \orcidID 0000-0002-2487-4744 Abstract This review focuses on the computerized modeling of the electrophysiology of the human atria, emphasizing the simulation of common arrhythmias such as atrial flutter (AFlut) and atrial fibrillation (AFib). Which components of the model are necessary to accurately model arrhythmogenic tissue modifications, including remodeling, cardiomyopathy, and fibrosis, to ensure reliable simulations? The central question explored is the level of detail required for trustworthy simulations for a specific context of use. The review discusses the balance between model complexity and computational efficiency, highlighting the risks of oversimplification and excessive detail. It covers various aspects of atrial modeling, from cellular to whole atria levels, including the influence of atrial geometry, fiber direction, anisotropy, and wall thickness on simulation outcomes. The article also examines the impact of different modeling approaches, such as volumetric 3D models, bilayer models, and single surface models, on the realism of simulations. In addition, it reviews the latest advances in the modeling of fibrotic tissue and the verification and validation of atrial models. The intended use of these models in planning and optimization of atrial ablation strategies is discussed, with a focus on personalized modeling for individual patients and cohort-based approaches for broader applications. The review concludes by emphasizing the importance of integrating experimental data and clinical validation to enhance the utility of computerized atrial models to improve patient outcomes. 1 Introduction The topic of this article is computerized modeling of the electrophysiology of the human atria, including the simulation of frequent arrhythmias, such as atrial flutter (AFlut) and atrial fibrillation (AFib). This also demands modeling of arrhythmogenic tissue modifications, such as disease-induced remodeling and atrial cardiomyopathy, including fibrosis [ 34 , 94 ] . We will focus on the question: ‘How much detail is really needed’? This seems to be a general principle: the more we look into the details of biological systems, the more complex they become. Generic models for specific species divide into different and more complex systems when we move to personalized models. But too many details pose risks and challenges to models: not only do calculation times increase but we might lose oversight and leave the regime of identifiable parameters for a given set of observations. As John von Neumann expressed it: “With four parameters I can fit an elephant, and with five I can make him wiggle his trunk” [ 25 ] . However, neglecting important details will lead to unrealistic results, predictions will not be reliable, and the model might fail to generalize and extrapolate beyond the data used to build it. The quality of any computerized modeling in medicine and in particular the answer to the question of the degree of detail that is needed can only be answered if an ’intended purpose’ or ’context of use’ of the model is specified [ 109 , 110 ] . In this article, the intended use is the planning and optimization of atrial ablation to stop reentrant arrhythmia and prevent recurrence. This includes both personalized modeling of the individual patient (digital twin) and modeling of cohorts with specific characteristics so that rules can be derived for optimal ablation strategies in subgroups with specific characteristics. This article moves along the biological levels of integration from cell modeling to modeling the whole atria. It covers aspects of heterogeneity, and modeling of diseased, remodelled and fibrotic tissue. It includes the influence of atrial geometry, left and right atria, wall thickness, fiber direction and anisotropy on simulation results. Figure 1 gives an outline of these aspects of computerized modeling of the atria. Figure 1: Aspects of computerized modeling of electrophysiology and pathoelectrophysiology of the atria with planning of successful ablation as the intended use. This article reports on progress since a previous review [ 26 ] . Review articles with different scope and focus but partial overlap were published lately [ 50 , 39 , 58 , 104 , 42 , 20 ] . Simulation and exploitation of ECG signals are not in the focus of this article and reviewed elsewhere [ 27 ] . 2 Cellular Modeling 11 years ago, we published an article comparing various atrial cell models [ 117 ] : the Courtemanche et al. model, the Grandi et al. model, the Maleckar et al. model and the Koivoumäki et al. model, and we observed small differences in the slope of the action potential but major differences in Ca 2+ handling, which will have strong influence on tension development. Meanwhile, there are several new cell models like e.g. Mazhar et al. [ 67 ] , but we do not intend to compare them all in this article. The Courtemanche model is the one that is still used most often. The conductivity of the ion channels of one type ( g_{i,\mathrm{max}} ) are not equal in all cells in a tissue but show a distribution [ 23 ] . These differences are smeared out to a large extent, when the cells are coupled via electrotonic coupling (e.g. via gap junctions). Cell models need modifications to adapt them to the properties of specific areas in the atria like e.g. pectinate muscles, the crista terminalis, the interatrial connections (e.g. Bachmann’s bundle) [ 95 , 49 ] and can be adapted to reflect gene mutations [ 61 , 62 ] or the effect of drugs [ 57 , 24 , 116 ] . Mechanoelectrical coupling will lead to modifications in cellular electrophysiology due to mechanical stress in atrial tissue. Since contraction of the atria during atrial systole is quite small, this effect might be neglected. But ventricular contraction is leading to significant mechanical stress in the atria. In computer simulations Appel et al. have demonstrated that this can have an effect on effective refractory period and might induce ectopic beats [ 4 ] . 2.1 Electrophysiological Remodeling due to AFib Cell models of the atria have to be modified to represent remodeling processes in response to AFib [ 47 ] . Experimentally reported results on changes of ion channel conductance and kinetics vary but for most channels a clear tendency can be condensed leading to an overall shorter action potential in cells that experienced persistent AFib conditions [ 60 ] . 2.2 Sinus Node Modeling Models of the sinus node have become more and more sophisticated. Obviously, we need cell models that depolarize periodically in an autonomous manner driven by an interplay of the “funny” ion current I f , the Ca 2+ homeostasis and the Na + / Ca 2+ exchanger NCX (‘calcium clock’) [ 46 ] . In addition, these pacemaker cells have to be embedded into the atrium in a specific way allowing the atrial myocardial cells to capture the excitation without putting too much electrical load on the sinus node cells (‘pace and drive’), for example by conductivity gradients and non-conducting structures to protect the sinus node cells from current drain [ 3 , 86 ] . Modeling the sinus node properly is a prerequisite for understanding sinus node arrhythmias like bradycardia [ 56 ] , for research on the influence of the autonomous system [ 52 ] and

Read the complete text