Read Design and implementation of the constant fraction discriminator for glass MRPC timing Journal: Nuclear Instruments and Methods in Physics Research A by L.L. Kurchaninov, E.A. Ladygin, V.P. Ladygin, A.A. Semak (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-22044.txt.

Introduction

Kurchaninov and three co-authors described the design of timing electronics in twenty twenty-five for a particle detector built from glass plates. The detector, a multigap resistive plate chamber, records when particles pass with extreme precision. Its front-end electronics use constant fraction discrimination, a method that times a pulse at a fixed share of its height, which cancels timing drift from pulses of varied size.

The team designed and tuned the analog front end for chambers with ten and twelve gaps. Tests with cosmic rays and a muon beam at an accelerator in Protvino reached a total time resolution of forty picoseconds. That precision meets the needs of the SPD experiment at the NICA collider. The paper reports the design choices behind the result.

Catalog record

CREATORL.L. Kurchaninov, E.A. Ladygin, V.P. Ladygin, A.A. Semak
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE23 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-22044

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Design and implementation of the constant fraction discriminator for glass MRPC timing Journal: Nuclear Instruments and Methods in Physics Research A L.L. Kurchaninov, E.A. Ladygin, V.P. Ladygin, A.A. Semak Abstract The analog front-end electronics based on the constant fraction discrimination method is designed and optimized for the Multigap Resistive Plate Chamber (MRPC) timing measurements. The total time resolution of ∼ \sim 40 ps has been obtained for 10 and 12 gaps MRPCs using cosmic setup and a muon beam at the IHEP U-70 accelerator in Protvino, which complies with the conditions of the SPD experiment at NICA. 1 Introduction High energy and heavy ion experiments require good particle identification based on the time-of-flight (TOF) techniques. MRPCs are widely used in large area TOF systems due to its good time resolution, high detection efficiency and relatively low cost production. In particular, MRPCs are used for particle identification at ALICE [ 1 , 2 , 3 ] , HARP [ 4 ] , STAR [ 5 ] , PHENIX [ 6 ] , BM@N [ 7 , 8 ] and other experiments. The Spin Physics Detector [ 9 ] is a universal facility for studying the nucleon spin structure and other spin related phenomena with polarized proton and deuteron beams placed at the second interaction point at NICA [ 10 ] . The SPD TOF system will also be based on MRPCs. The purpose of the MRPC system is to make a 3 \sigma separation of \pi / K and K / p in the momentum range up to few GeV/ c . The required time resolution of the SPD MRPC system is \sim 60 ps [ 9 ] . Typically, the total time resolution of MRPC systems achieved in present experiments is 50 \div 70 ps. The best time resolution of \sim 20 ps has been obtained for an MRPC having 24 gas gaps with a width of 160 \mu m built of thin 400 \mu m "soda-lime" glass sheets after the correction for the time slewing [ 11 ] . The time resolution of an MRPC is mainly determined by the detector intrinsic resolution, which depends on the design and physics of the gas discharge; the jitter of the front-end electronics (FEE) and cables; and the time-to-digit converter (TDC) channel uncertainty. Improvement of the MRPC time resolution requires correction for the time slewing, which arises from the signal time delay dependence on its amplitude. Therefore, the time of the leading edge has to be corrected for the signal amplitude. Nowadays, the MRPC signal amplitude is usually estimated using the fast Time-Over-Threshold (ToT) method, which only reads out the threshold crossing time and the signal time interval over the threshold. FEE based on NINO ASIC with an embedded ToT function [ 12 , 13 ] and TDC system built using the HPTDC ASIC [ 14 ] can provide contribution to the total time resolution of \sim 20 ps [ 11 ] . Another way is to analyze the MRPC signal waveform. In particular, the NA61 MRPC system [ 15 , 16 ] is based on the use of a fast analog amplifier and DRS4 module [ 17 ] for the signal waveform analysis. The time resolution of the fast analog FEE and high-speed DRS4 based [ 18 ] waveform digitization module, integrating the waveform correction and filtering, digital discrimination and linear interpolation is better than 10 ps [ 19 ] . A new analysis method based on a neural network and machine learning algorithms was proposed and implemented to make the best use of the MRPC signal waveform [ 20 , 21 ] . The MRPC time resolution obtained by this method using 7 points on the signal leading edge was found better than provided by the traditional ToT [ 21 ] . The constant fraction discrimination method [ 22 ] is widely used for TOF measurements [ 23 ] . The fast discriminator which triggers at a constant fraction of the input signal amplitude allows to obtain the optimum time resolution regardless of the signal amplitude. In this case there is no need for the time slewing effect correction. Moreover, a constant fraction discriminator (CFD) is suitable for large scale systems due to its simplicity and low cost. This paper presents first results on the design, optimization and first application of the FEE based on the constant fraction discrimination method for the SPD MRPC system [ 9 ] . The paper is organized as follow. Section 2 describes the MRPC design used for the studies and analysis of their signal shapes. The constant fraction discriminator concept and schematics is discussed in Section 3 . The results of the cosmic muons and muon beam test at the U70 accelerator are described in Section 4 and Section 5 , respectively. The conclusions are drawn in the last Secton. 2 MRPC Four MRPCs were manufactured for the present studies. The two studied MRPCs have 10 and 12 gas gaps in total, while two others used for the trigger purpose have 10 gas gaps. Each MRPC consists of two identical 5- or 6-gap stacks with an anode strip readout plate in between. The schematic cross section of a 10-gap MRPC is shown in Fig. 1 . Figure 1: The schematic view of a 10-gap MRPC. Each gas gap is formed by two 0.55 mm thick glass plates with a bulk resistivity of 3 \times 10 13 \Omega cm. The gap between the glass plates is defined by a spacer made of fishing line 250 \mu m in diameter. Graphite conductive coating with a surface resistivity of 2–5 M \Omega /square is painted on outer surfaces of the stacks to distribute high voltage to create an electric field in the sensitive area. The anode readout plate is a one-sided PCB with a thickness of 100 \mu m. The thickness of the copper coating is 35 \mu m. The sensitive area of the MRPC is 16 \times 35.1 cm 2 . The MRPC has 32 10 \times 160 mm 2 readout strips with 1 mm gaps between them. The signals are read on both ends of the anode strips. Each MRPC is enclosed in a gas-tight aluminium box. The bottom of the box is made of a double-sided PCB (motherboard) with a thickness of 2.5 mm. The top of the box is covered by an aluminium plate 1.5 mm thick. The MRPCs were operated at a high voltage across the gap up to 3 kV with \sim 50 cc/min flow of 90% C 2 F 4 H 2 , 5% SF 6 and 5% C 4 H 10 gas mixture. The simulation based on the simple Townsend model [ 24 ] of gas discharge shows that the intrinsic time resolution of an MRPC with 10 gas gaps of 250 \mu m thickness each is \sim 20 ps [ 25 ] . Figure 2: Averaged signals from the 12-gap and 10-gap MRPCs shown by the squares and circles, respectively (left panel). The signal amplitudes from the 12-gap MRPC (right panel). The MRPC signal shape was studied with cosmic muons. For this purpose, the two studied and two trigger MRPCs were stacked vertically on the top of each

Read the complete text