Superstability of micrometer jets surrounded by a polymeric shell

A. Rubio \IUCrEmaillink [email protected], J. M. Montanero \IUCrCemaillink [email protected], M. Vakili \IUCrEmaillink [email protected], F. H. M. Koua \IUCrEmaillink [email protected], S. Bajt \IUCrEmaillink [email protected], H. N. Chapman \IUCrEmaillink [email protected], A. M. Gañán-Calvo \ · 2025

Read Superstability of micrometer jets surrounded by a polymeric shell by A. Rubio \IUCrEmaillink [email protected], J. M. Montanero \IUCrCemaillink [email protected], M. Vakili \IUCrEmaillink [email protected], F. H. M. Koua \IUCrEmaillink [email protected], S. Bajt \IUCrEmaillink [email protected], H. N. Chapman \IUCrEmaillink [email protected], A. M. Gañán-Calvo \ (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-20965.txt.

Introduction

Rubio and co-authors build liquid microjets that refuse to break up in a 2025 fluids paper. Their injector, printed in 3D, focuses two streams together: a watery core wrapped in a thin shell of weak polymer solution, only a few hundred nanometers thick. Bare jets need a minimum flow to stay stable; the polymer skin lowers that floor tenfold.

The result is jets far thinner and longer than the setup could make before. Stability at a trickle matters for serial femtosecond crystallography, where protein crystals ride a jet through an X-ray beam one shot at a time. A jet that survives slow delivery wastes less precious sample per picture.

Catalog record

CREATORA. Rubio \IUCrEmaillink [email protected], J. M. Montanero \IUCrCemaillink [email protected], M. Vakili \IUCrEmaillink [email protected], F. H. M. Koua \IUCrEmaillink [email protected], S. Bajt \IUCrEmaillink [email protected], H. N. Chapman \IUCrEmaillink [email protected], A. M. Gañán-Calvo \
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE26 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-20965

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Superstability of micrometer jets surrounded by a polymeric shell A. Rubio \IUCrEmaillink [email protected], J. M. Montanero \IUCrCemaillink [email protected], M. Vakili \IUCrEmaillink [email protected], F. H. M. Koua \IUCrEmaillink [email protected], S. Bajt \IUCrEmaillink [email protected], H. N. Chapman \IUCrEmaillink [email protected], A. M. Gañán-Calvo \IUCrEmaillink [email protected] Abstract We have produced superstable compound liquid microjets with a three-dimensional printed coaxial flow-focusing injector. The aqueous jet core is surrounded by a shell, a few hundred nanometers in thickness, of a low-concentration aqueous solution of a low-molecular-weight polymer. Due to the stabilizing effect of the polymeric shell, the minimum liquid flow rate leading to stable flow-focusing is decreased by one order of magnitude, resulting in much thinner and longer jets. Possible applications of this technique for Serial Femtosecond X-ray Crystallography are discussed. {synopsis} Superstable micrometer compound jets are produced for Serial Femtosecond X-ray Crystallography 1 Introduction X-ray free-electron lasers produce highly energetic and coherent pulses of X-rays with femtosecond duration. By providing a probe with a wavelength that can access atomic scales with a pulse commensurate with the time scales of atomic motions, these machines have opened new ways to study the structure and dynamics of condensed matter, liquids, and gases, covering fields ranging from planetary science, atomic physics, and structural biology [ Bostedt:2016 ] . When the X-ray pulses are tightly focused, the resulting extreme intensity vaporizes material, so many experiments are carried out by rapidly replacing or refreshing the exposed sample prior to the next pulse. The first macromolecular crystallography experiments conducted at a hard X-ray free-electron laser (XFEL) faced the challenge of introducing hydrated protein crystals to the X-ray beam, in a vacuum environment, to be exposed and refreshed at a rate of 120 pulses per second [ Chapman:2011 ] . This was achieved using a liquid jet of a slurry of nanocrystals, formed by gas focusing [ G98a ] using a gas dynamic virtual nozzle [ DWSWSSD08 ] . Since those first experiments, liquid jets have been used for many serial femtosecond crystallography (SFX) experiments at all XFEL facilities around the world, and developments of nozzles and microfluidic mixers [ Knoska:2020 , Doppler2023 ] have enabled mix-and-inject crystallography [ Schmidt:2013 ] and pump–probe time-resolved crystallography of photoactive proteins [ Branden:2021 ] . The same instrumentation is also used for solution scattering [ Arnlund:2014 , Blanchet:2023 ] and fiber diffraction [ Popp:2017 ] , and similar jets are used in spectroscopy experiments of liquids [ Lemke:2017 ] . The high speeds, of more than 50 m/s that micrometer-diameter gas-focused jets can reach [ Knoska:2020 ] , enabled the adoption of serial crystallography with the megahertz pulse trains of the European XFEL [ Wiedorn:2018 ] . Many innovations and variations of liquid ejection have been developed for the priorities of specific experiments, such as acoustic injection to reduce sample consumption at e.g. 120 Hz repetition rate [ Roessler:2016 ] , and sheet jets for reduced scattering background and to provide a constant interaction volume with the X-ray beam for spectroscopy measurements [ Konold2023 ] . However, the basic cylindrical jet configuration offers multiple advantages such as robustness, ease of use, consistency, high sample velocities (for high repetition rates of X-ray pulses), and compatibility with a wide range of sample types. Designs for cylindrical micro-jets have therefore continued to evolve towards a more stable and efficient sample delivery as well as support of measurements over an increased range of time spans. A strategy to achieve this is to separate the dual functions of the liquid as a medium to carry crystals and to form a stable jet, by using a concentric flow of two liquids [ G98a ] . This was realized by using a double-flow focusing nozzle (DFFN) to flow an outer sheath of liquid of low surface tension such as ethanol over the central buffer containing the crystals, all focused by gas [ Oberthuer:2017 ] . The flow of the sample-containing liquid can be reduced arbitrarily without affecting the jet, which is formed by the sheath liquid. Here, we extend the concept of utilizing two fluids to achieve even higher control and stability of the flowing jet, and to reach a wider span of time delays by extending the jet length. Until now, most of the liquids used in sample delivery exhibit quasi-Newtonian mechanical properties, which necessitates increasing the viscosity of the buffer to lengthen the jet and enhance its stability. It has been recently shown that diluted solutions of specific polymers can significantly extend the jet length while reducing the liquid flow rate by an order of magnitude [ RGVMC22 , RVGM22 ] . These polymers can adhere to the sample requirements. This method presents a new opportunity to improve the conventional approaches in liquid sample handling formulations. In this study, we apply a non-invasive method in which a pre-existing buffer formulation is maintained within the core of the jet. The core is enveloped by a shell (film) of a miscible low-concentration water solution containing a compatible polymer. We aim to determine whether the increased jet length observed in simple jets occurs in a compound or armored jet, akin to a continuously flowing sausage. This setup required implementing a concentric flow focusing technique [ G98a ] utilized in previous research [ Oberthuer:2017 , Vakili:2022 ] . Our findings confirm our expectations and reveal unexpected benefits that significantly enhance the importance of the involved nonlinear fluid-dynamics phenomena, meriting further detailed examination. 2 Methods The gaseous flow-focusing ejector employed in this study was printed using the Nanoscribe Photonic Professional GT2 with the Dip-in Laser Lithography (DiLL) configuration, a 25 \times objective lens, and the IP-S photoresist. The typical slicing and hatching distances were 1 \mu m and 0.5 \mu m, respectively. These distances are much smaller than the lengths characterizing the nozzle. Therefore, one does not expect the nozzle fabrication reproducibility to affect the results. The ejector consisted of a concentric annular duct coaxially placed inside a converging nozzle (Fig. 1 ). The focused liquid was injected across the inner capillary at a constant flow rate Q_{i} with a syringe pump (LEGATO210, KD-SCIENTIFIC). The fluid shell was injected through the outer capillary at a constant flow rate Q_{o} with another identical syringe pump. The gaseous stream was helium. The helium mass flow rate was measured with a mass flow meter (FLOW-BUS, BRONKHORST). We mounted the ejector onto the cap of a discharge glass cell and established a pressure of 25 mbar inside the cell using a suction pump. Figure 1: CAD screenshot of the nozzle with indications of geometric design parameters. We used a high-speed video camera (Fastcam Mini UX50) to take digital microscopy images of the jet at 4000 fps. The camera was equipped with optical lenses ( Optem Zoom 70XL ) and a microscope objective ( Optem 10X). The images consisted of 974 \times 768 pixels. The magnification was 4.5 \times , which resulted in 0.222 \mu m/pixel. We illuminated the jet with a laser (SI-LUX 640, Specialized Imaging ) synchronized with the camera, which reduced the effective exposure time down to 150 ns. To examine the jet behavior at different jet stations, the camera was displaced vertically using a triaxial translation stage with its vertical axis motorized ( Thorlabs Z825B) and controlled

Read the complete text