Modeling and Constraint-Aware Control of Pressure Dynamics in Water Electrolysis Systems footnoteinfo This material is based upon work supported by the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE001
Mostafaali Ayubirad, Madiha Akbar, Hamid R. Ossareh · 2025
Read Modeling and Constraint-Aware Control of Pressure Dynamics in Water Electrolysis Systems footnoteinfo This material is based upon work supported by the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE001 by Mostafaali Ayubirad, Madiha Akbar, Hamid R. Ossareh (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-16935.txt.
Introduction
Ayubirad, Akbar, and Ossareh hold gas-split cell push in bounds with a guard tool in this twenty twenty-five paper. Such cells split water for fuel gas cross a wide force range. Fast force swings can push cell push past safe build caps.
Inside, a lean cell build tracks push and flow acts for the guard. The guard trims force asks ere push can cross its set cap. Sim runs show push held in bounds through wild force swings. The guard beat plain smooth tricks on both push and yield. Gas yield rose while aux fuel use fell in the same runs.
Catalog record
| CREATOR | Mostafaali Ayubirad, Madiha Akbar, Hamid R. Ossareh |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2505-16935
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Modeling and Constraint-Aware Control of Pressure Dynamics in Water Electrolysis Systems footnoteinfo This material is based upon work supported by the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE0010147. The views expressed herein do not necessarily represent the views of the U.S.Department of Energy or the United States Government Mostafaali Ayubirad, Madiha Akbar, Hamid R. Ossareh Abstract This paper addresses the challenge of pressure constraint violations in water electrolysis systems operating under dynamic power conditions, a problem common to both Proton Exchange Membrane and alkaline technologies. To investigate this issue, a control-oriented model of an alkaline electrolyzer is developed, capturing key pressure and flow dynamics. To manage rapid power fluctuations that may cause pressure to exceed manufacturer-defined operational boundaries, a model-based constraint-aware power governor based on the Reference Governor (RG) framework is proposed. Simulation results show that the strategy effectively maintains pressure within the specified operating range, outperforming conventional filtering methods while enhancing hydrogen production and reducing auxiliary energy consumption. keywords Water Electrolysis, Modeling, Constraint Management, Reference Governor 1 Introduction As the global energy landscape evolves, the demand for efficient and scalable energy storage solutions is increasing. Hydrogen has recently emerged as a promising energy carrier due to its high energy density and notable calorific value, making it well-suited for compact, large-scale, and long-duration storage applications ( Akyüz et al. 2024 ). Among the available hydrogen production methods, water electrolysis is currently regarded as the most efficient technology, known for producing high-purity and scalable green hydrogen, particularly when powered by renewable sources ( Akyüz et al. 2024 ). Efforts to reduce the cost of green hydrogen have focused on several electrolysis methods, such as alkaline, proton exchange membrane (PEM), solid oxide (SO), and anion exchange membrane (AEM) systems. Alkaline and PEM electrolysis, in particular, have reached higher levels of technological readiness and commercialization, driving rapid progress in their real-world application ( Taibi et al. 2020 ). However, despite the advancements, large-scale deployment of electrolyzers in energy infrastructure remains limited by persisting safety, durability, and cost challenges ( Hu et al. 2022 ). Therefore, to tackle these challenges, gaining a deeper understanding of the electrolyzers and developing efficient control mechanisms for improving their operational flexibility is crucial. For these reasons, in recent years, a significant effort has been made to model, characterize and analyze the operation of electrolyzers. In this regard, one of the most widely used models to describe the behavior of both PEM and alkaline electrolyzers was developed by Ulleberg 2003 . The model describes the polarization curve and also accounts for the thermal behavior of the system and the Faraday efficiency of the stack. To improve voltage prediction, Sánchez et al. 2018 modified Ulleberg’s model to account for pressure effects in the polarization curve. David et al. 2020 and Cantisani et al. 2023 developed dynamic models of electrolyzer pressure based on mass balance and thermodynamic principles, providing accurate representations of system pressure. However, these large-scale, physics-based models involve dozens of parameters that must be tuned experimentally through a complex identification process. This highlights the need for a simpler, yet effective, control-oriented model that can capture the essential pressure dynamics for the development of pressure control strategies. Pressure control is a key objective for ensuring the safe and efficient operation of electrolyzer systems. Existing studies on electrolyzer pressure control typically rely on methods such as Proportional-Integral (PI) to maintain constant system pressure, often by treating the applied power as a disturbance to be rejected ( Aguirre et al. 2024 ). Severe power ramps can jeopardize the operation of the electrolyzer ( Li et al. 2023 ), as the system pressure may exceed the acceptable range defined by the manufacturer during transient conditions. To mitigate these issues and extend the electrolyzer’s lifespan, a controlled, gradual change in power input using approaches such as a conventional low-pass filter (LPF) has been recommended during instantaneous transients ( Zhou and Francois 2009 ; Li et al. 2023 ). Low-pass filtering of the input power can help prevent constraint violations but is usually conservative. Currently, the development of constraint-based control strategies for managing changes in input power remains unexplored in the literature. Reference Governor (RG) strategies have been successfully applied in related energy systems, such as hydrogen fuel cell vehicles, to enforce operational constraints in a computationally efficient manner ( Ayubirad and Ossareh 2024 ; Ayubirad and Ossareh 2025 ; Bacher-Chong et al. 2023 ). In this paper, we treat the input electric power as a controllable variable and develop a Power Governor (PG) strategy based on the RG framework, which modifies the input power, only as needed, for constraint enforcement. In sum, the main objective of this research is to investigate a constraint-aware PG for managing pressure in water electrolysis systems under dynamic power input, addressing limitations of existing approaches. As such, the original contributions of this paper are as follows: • A physics-based, control-oriented model of electrolyzer pressure dynamics, including control loops and actuators, that can capture hydrogen pressure violations during large, rapid input power transients. • A constraint enforcement strategy for hydrogen pressure using an RG that ensures pressure remains within acceptable limits by adjusting the input power only when necessary. • A performance comparison between the proposed PG and a conventional LPF, to demonstrate improvements in hydrogen production, power tracking, and auxiliary energy consumption. The remainder of the paper is organized as follows. Section 2 presents the mathematical modeling of system pressure along with the problem statement. Section 3 introduces the proposed constraint management scheme and presents simulation studies and discussions. Conclusions are provided in Section 4 . 2 Control design model and problem description This section presents a control-oriented model of the electrolyzer, focusing on pressure dynamics and the motivation for advanced pressure control under power transients. While the developed strategies apply to various types of electrolyzers, we focus on alkaline systems due to their widespread use and to maintain precision in our analysis. 2.1 Control-Oriented Model This section presents a model of the alkaline electrolyzer system. The stack temperature is assumed to remain constant and uniformly distributed at T_{\text{el}}=80\,^{\circ}\text{C} , as its dynamics are considerably slower than other dynamics considered. To concentrate on hydrogen pressure management, the model emphasizes pressure dynamics, control loops, and actuator behavior. The dynamic pressures of reaction products inside the electrolyzer are computed based on the cathode and anode flow models. The main flows associated with the electrolyzer stack are shown in Fig. 1 , where W_{H_{2},\text{gen}} and W_{O_{2},\text{gen}} represent the rates at which hydrogen and oxygen are generated, while W_{H_{2},\text{out}} and W_{O_{2},\text{out}} denote the flow rates of hydrogen and oxygen leaving the system. Figure 1: Illustrative electrolyzer system diagram with key variables. The variables in parentheses are state variables, while the variables in braces are input variables determined by the controllers. The mass continuity is used to balance the mass of hydrogen and oxygen, as shown by: \displaystyle\frac{dp_{O_{2}}}{dt} \displaystyle=\frac{R_{O_{2}}T_{\text{el}}}{V_{\text{an}}}\left(W_{O_{2},\text{gen}}-W_{O_{2},\text{out}}\right), (1) \displaystyle\frac{dp_{H_{2}}}{dt} \displaystyle=\frac{R_{H_{2}}T_{\text{el}}}{V_{\text{ca}}}\left(W_{H_{2},\text{gen}}-W_{H_{2},\text{out}}\right). Here, p_{O_{2}} and p_{H_{2}} denote the partial pressures of oxygen and hydrogen, respectively; R_{O_{2}} and R_{H_{2}} are the specific gas constants for oxygen and hydrogen; and V_{\text{ca}} and V_{\text{an}} represent the cathode and anode volumes, respectively. The thermodynamic