An automated algorithmic method to mitigate long-term variations in the efficiency of the GRAPES-3 muon telescope
S. Paul, K.P. Arunbabu, M. Chakraborty, S.K. Gupta, B. Hariharan, Y. Hayashi, P. Jagadeesan, A. Jain, P. Jain, M. Karthik, S. Kawakami, H. Kojima, K. Manjunath, P.K. Mohanty, S.D. Morris, Y. Muraki, P.K. Nayak, T. Nonaka, A. Oshima, D. Pattanaik, B. Rajesh, M. Rameez, K. Ramesh, B.S. Rao, L.V. Reddy · 2025
Read An automated algorithmic method to mitigate long-term variations in the efficiency of the GRAPES-3 muon telescope by S. Paul, K.P. Arunbabu, M. Chakraborty, S.K. Gupta, B. Hariharan, Y. Hayashi, P. Jagadeesan, A. Jain, P. Jain, M. Karthik, S. Kawakami, H. Kojima, K. Manjunath, P.K. Mohanty, S.D. Morris, Y. Muraki, P.K. Nayak, T. Nonaka, A. Oshima, D. Pattanaik, B. Rajesh, M. Rameez, K. Ramesh, B.S. Rao, L.V. Reddy (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-16440.txt.
Introduction
A large team led by Paul presents an automatic fix in a 2025 paper for drift in a vast muon scope in India. The scope, with sixteen parts, watches high-power muons fall through more than half the sky. Its counts are marred by slow drift and sudden shifts in how well parts work.
Their method cuts the data stream into blocks where the rate holds near steady, using a rule that needs no hand tuning. Stale stretches can then be flagged and the true rate restored. Clean rates matter, since muons trace storms in the Sun and air. Scope teams gain a hands-off way to keep long records true.
Catalog record
| CREATOR | S. Paul, K.P. Arunbabu, M. Chakraborty, S.K. Gupta, B. Hariharan, Y. Hayashi, P. Jagadeesan, A. Jain, P. Jain, M. Karthik, S. Kawakami, H. Kojima, K. Manjunath, P.K. Mohanty, S.D. Morris, Y. Muraki, P.K. Nayak, T. Nonaka, A. Oshima, D. Pattanaik, B. Rajesh, M. Rameez, K. Ramesh, B.S. Rao, L.V. Reddy |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 46 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2505-16440
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
An automated algorithmic method to mitigate long-term variations in the efficiency of the GRAPES-3 muon telescope S. Paul, K.P. Arunbabu, M. Chakraborty, S.K. Gupta, B. Hariharan, Y. Hayashi, P. Jagadeesan, A. Jain, P. Jain, M. Karthik, S. Kawakami, H. Kojima, K. Manjunath, P.K. Mohanty, S.D. Morris, Y. Muraki, P.K. Nayak, T. Nonaka, A. Oshima, D. Pattanaik, B. Rajesh, M. Rameez, K. Ramesh, B.S. Rao, L.V. Reddy, S. Shibata, K. Tanaka, F. Varsi, M. Zuberi Abstract The GRAPES-3 large area muon telescope with its sixteen independent modules records the high energy ( > > 1 GeV) muons continuously over 2.3 sr of the sky. However, the recorded muon rates are contaminated by instrumental effects and instabilities spanning both short- and long-timescales, such as variations in the efficiency of the detector. We present an automated, algorithmic method, which employs Bayesian blocks to discretize the data stream into periods and exploits the correlations among the sixteen independent modules of the muon telescope to separate the impact of these instrumental problems from those originating in physical effects of interest, allowing the Savitzky-Golay filter to be employed to mitigate the former. Compared to legacy methods, this method is less dependent on subjective input from experimental operators and provides a data stream free of all known instrumental effects over calendar years. The muon rate obtained with the new method shows a fairly better correlation with neutron monitor data, than that obtained with the legacy method. keywords GRAPES-3, muon telescope, efficiency, neutron monitor 1 Introduction The G amma R ay A stronomy at P eV E nergie S - phase 3 (GRAPES-3) is a ground-based cosmic ray (CR) experiment designed primarily to record extensive air showers (EASs) in the energy (of the primary) range of 10 TeV–10 PeV and more. Its large area (560 m 2 ) muon telescope, hereafter referred to as G3MT (GRAPES-3 muon telescope) samples the muon content in the EASs, enabling the gamma-initiated EASs to be differentiated from hadron-initiated ones. In addition, it also records the angular muon rate above a GeV, produced by EASs initiated by primaries with energies of 10 GeV and above, enabling the study of near-Earth and atmospheric phenomena as well as the modulation of CRs by the solar system. In continuous operation since the year 2000, data produced by G3MT has enabled path-breaking studies of the long-term modulation of CR flux Arunbabu (2017) ; Kojima (2024) , atmospheric acceleration Hariharan (2019) , interplanetary coronal mass ejections Mohanty (2016) ; Mohanty (2018) , and solar and heliospheric phenomena Subramanian, P. et al. (2009) ; Arunbabu, K. P. et al. (2013) ; Arunbabu, K. P. et al. (2015) , as well as measurements of the spectrum and anisotropy in the arrival directions of CRs Varsi (2024) ; Chakraborty (2024) . These studies allow probing of the origin and propagation of CRs within the atmosphere, solar system, and Milky Way, respectively. However, before any physics studies can be performed, it is necessary to mitigate the variations in G3MT data originating from known systematic and instrumental effects. Atmospheric pressure is one of the major sources of periodic systematic variations, and can be easily corrected for if precise measurements of the atmospheric pressure on site are available, whereas correcting for instrumental effects is nontrivial since it is challenging to confidently decouple such efforts from physical phenomena. The instrumental effects can be broadly divided into (i) short- and (ii) long-term effects, typically attributed to momentary and localized issues at various stages of signal processing, and slow decline in detectors’ efficiency, respectively. The former introduces incurable errors in the data from individual modules of G3MT in most scenarios, with the time span ranging anywhere from a few minutes to several hours. The latter introduces a slow decline in the overall performance of specific G3MT modules and can be observed on longer time scales (i.e., ranging from a few months to years) – requiring corrective measures before the data can be used for studies of long-term CR modulation Mohanty et al. (2018) . Traditionally, this has been achieved by identifying a reference module based on the judgment of the experiment operators Mohanty et al. (2018) . While this has so far served the purpose, as the experiment continues to operate into the future, automated, algorithmic methods that are less susceptible to human subjectivity become necessary. Since G3MT is a collection of sixteen independent telescope modules, the correlation between the muon rates in the different modules can be used as a reference to overcome the above-mentioned issues without affecting the variations caused by physical phenomena. To address this, methods have been developed to model both short- and long-term instrumental variations, with corresponding corrections implemented. This report provides a detailed summary of these efforts. The next section discusses the GRAPES-3 experiment and its detectors. Sec. 3 discusses various types of systematic and instrumental effects and their respective causes. The latter Sec. 4 discusses the streamlined and automated approach to parameterization and correction of systematic and instrumental effects. Once these effects are corrected, the independent muon module rates may be combined to form omni and multi-directional muon rate profiles for physics studies. These methods are suitable for application to data from other experiments that record CR flux, and has the potential to reduce systematic uncertainties. 2 The GRAPES-3 muon telescope GRAPES-3 is a ground-based observatory located in the Nilgiri mountains in Ooty, India (11.4 ∘ N, 76.7 ∘ E, 2200 m above mean sea level). It consists of two detector elements, (i) an array of 400 plastic scintillator detectors (G3SD) spread over, 25000 m 2 Gupta (2005) and (ii) a large area (560 2 ) tracking muon telescope (G3MT) Hayashi (2005) . The G3SD is tuned to record EASs produced by the CRs in a broad energy range of 10 TeV–10 PeV, bridging the reach of direct and indirect detection experiments Hariharan (2020) . The G3MT consists of sixteen independent muon modules (35 2 each) arranged in four logical groups called muon super-modules (Fig 2, 3, and 4 of Hayashi (2005) ). Each muon module is built using four layers of proportional counters (PRCs). The PRC is a gas ionization detector made up of a mild steel tube of dimension 600 \times 10 \times 10 cm 3 . The tubes are sealed at both ends and filled with a P10 gas mixture (90% argon and 10% methane) at a pressure of approximately 25% above the local atmospheric pressure. In the center, a 100 \mu m thick tungsten wire is laid, serving as an anode, while the metal body is the cathode. The anode and cathode are electrically isolated using glass-to-metal hermetic seal. Each PRC is electrically biased with approximately, 3000 V {}_{\text{DC}} . 58 PRCs are tightly placed in each layer. Alternate layers are placed orthogonally to each other and sandwiched with 15 cm thick concrete slabs in between. Above the top-most layer, a 2 m thick concrete absorber ( \sim 550 g cm -2 ) in an inverted pyramidal shape with an inclination of 45 ∘ ensures the filtering of soft components and provides an energy threshold of 1 GeV for vertical muons, and sec( \theta ) GeV for muons incident at an angle \theta . Figure 1