High-Throughput Mechanical Characterization of Giant Unilamellar Vesicles by Real-Time Deformability Cytometry
Maximilian Kloppe, Stefan J. Maurer, Tobias Abele, Kerstin Göpfrich, Sebastian Aland · 2025
Read High-Throughput Mechanical Characterization of Giant Unilamellar Vesicles by Real-Time Deformability Cytometry by Maximilian Kloppe, Stefan J. Maurer, Tobias Abele, Kerstin Göpfrich, Sebastian Aland (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-15341.txt.
Introduction
Maximilian Kloppe, Stefan Maurer, Tobias Abele, Kerstin Göpfrich, and Sebastian Aland wrote a 2025 biophysics paper on measuring the stiffness of giant artificial cell bubbles at high speed. Real time deformability cytometry squeezes soft objects in flow and reads their shape change without contact. Applying it to vesicles, synthetic bubbles wrapped in a lipid skin, needed a proper mechanical model.
Phase field simulations across a wide parameter range showed deformation grows in a simple linear way with vesicle area. From that, the team built two fitting methods for the skin's area expansion modulus: one careful fit per vesicle, and one noise resistant method for whole populations. A combined method filters outliers for messy samples. All versions held up across flow rates and channel shapes.
Catalog record
| CREATOR | Maximilian Kloppe, Stefan J. Maurer, Tobias Abele, Kerstin Göpfrich, Sebastian Aland |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 48 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2505-15341
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
High-Throughput Mechanical Characterization of Giant Unilamellar Vesicles by Real-Time Deformability Cytometry Maximilian Kloppe, Stefan J. Maurer, Tobias Abele, Kerstin Göpfrich, Sebastian Aland Abstract Real-time deformability cytometry (RT-DC) enables high-throughput, contact-free mechanical characterization of soft microscopic objects. Here we apply this technique to giant unilamellar vesicles (GUVs). To interpret vesicle deformation in RT-DC, we present a simulation-based model taking into account the area expansion modulus as the dominant mechanical parameter. Using phase-field simulations over a wide parameter space, we find GUV deformation to depend linearly on GUV area. Based on these results, we derive two complementary fitting strategies for extracting the area expansion modulus K K from RT-DC data: a direct model-based fit for single-vesicle characterization and a noise-resistant collective approach that enables robust population-level estimates. Furthermore, we introduce a combined fitting method that integrates both approaches to filter outliers and improve accuracy in heterogeneous or noisy datasets. All methods scale across varying flow rates, channel geometries and buffer viscosities, and produce predictions of K K consistent with literature values for different lipid compositions. Compared to traditional techniques such as micropipette aspiration, our approach offers orders of magnitude higher throughput without mechanical contact, making it particularly suitable for GUV population studies. Beyond mechanical phenotyping, this framework opens new avenues for sorting vesicle populations based on membrane mechanics, a capability of growing interest in synthetic biology and soft matter research. 1 Introduction Giant unilamellar vesicles (GUVs) serve as versatile model membrane systems in biophysical research for studying biological processes such as lipid phase separation [ 33 ] , membrane fusion [ 7 ] and protein-lipid interactions [ 37 , 30 ] . In addition, GUVs are used in biomedical applications such as targeted drug delivery [ 4 ] or synthetic cell design [ 31 ] . Their versatility stems from their cell-mimicking size (diameter >1\,$\mathrm{\SIUnitSymbolMicro m}$ ), which allows for direct observation of the membrane responses to external factors such as ions, molecules, or hydrodynamic flows under a microscope [ 8 ] . In addition, GUVs share many structural similarities with cellular membranes, while providing precise control over factors such as membrane composition, mechanics and functionality [ 37 , 18 , 8 , 3 ] . Mechanical parameters, including deformability, elasticity, and membrane tension are fundamental factors influencing the behavior of GUVs and their various applications. These properties govern how the vesicles undergo dynamic shape changes, maintain structural integrity under external forces, and respond to environmental stresses. At the same time, the mechanical parameters are closely linked to the vesicle composition and are particularly influenced by factors such as lipid types, bilayer thickness and the presence of proteins [ 26 , 29 ] . The mechanical properties of cells, on the other hand, are often attributed to their cytoskeleton rather than the membrane itself. GUVs, in presence and absence of cytoskeletal elements, provide the unique opportunity to decouple these effects [ 9 ] . However, determining mechanical parameters of GUVs experimentally remains challenging and time consuming. For example, micropipette aspiration experiments [ 26 ] , response measurements to compression between parallel plates [ 28 ] or indentation with a conical AFM-tip [ 29 ] have been used to measure the elastic behaviour of GUVs. A common limitation of these methods is their relatively slow throughput, as they typically allow for the characterization of only one vesicle at a time. Microfluidic deformability cytometry offers rapid characterization of thousands of GUVs within minutes, potentially enabling ultra-fast screening of large vesicle populations. One advanced method is real-time deformability cytometry (RT-DC), which provides high-throughput, real-time measurements by subjecting the vesicles to controlled flow forces within a microfluidic channel [ 23 ] . As the vesicles traverse the channel, their deformation can be measured and analyzed to potentially quantify the mechanical parameters of GUVs such as elasticity and membrane tension. As an added advantage, the GUVs are not in contact with surfaces during the measurement, which, depending on the type of surface interaction can strongly influence the measurement and make the comparison of different conditions challenging. Predictions of mechanical properties in RT-DC rely on matching experimentally observed cell deformation with theoretical models. For cells, such theoretical models exist and have been used extensively with RT-DC to study the mechanical properties of cells, allowing rapid phenotyping and mechanical profiling [ 16 , 17 , 23 , 27 , 10 , 36 , 35 ] . These models consider elastic and viscoelastic materials and are able to link shape deformation with concrete elastic moduli. However, all models consider either volumetric structures (i.e. solid bodies) or elastic shells. Lipid vesicle membranes are neither and hence cannot be evaluated with the current models. Here, we provide a theoretical method to describe GUV deformation and to measure lipid elastic properties in an ultrafast manner in RT-DC. To this end, we present first numerical simulation results of fluid vesicles in RT-DC channels. To eliminate the influence of experimental noise we introduce a new fitting algorithm which allows real-time extraction of the area expansion modulus of a vesicle sample despite errors in the imaging data. Finally, we illustrate the generality of the approach to deliver accurate estimates when using RT-DC setups of arbitrary flow rates, channel sizes and buffer viscosities. 2 Results 2.1 Deformation of a GUV in a microfluidic channel Lipid vesicles like GUVs are fluid filled compartments with a bilayer of densely packed lipid molecules at their surface. The lipid molecules (in the liquid disordered state) can freely move in the tangential direction along the surface, which implies a vanishing surface shear modulus. On the other hand, the lipid layer resists bending, areal compression and stretching. It has been shown that the stiffness against bending deformations is negligible in RT-DC measurements due to the large forces exerted [ 17 ] . However, the layer’s resistance to compression and stretching contributes significantly. The corresponding area expansion modulus K is hence the dominant mechanical parameter and the only determinant of vesicle shapes. To extract K from RT-DC image data, we simulate GUV deformation in dependence of K . We therefore model GUVs as initially spherical thin, freely-shearable elastic surfaces with radius r immersed in a buffer liquid of viscosity \eta , within an RT-DC channel with a square-shaped cross-section of side length L , see Fig. 1 A. A flow rate Q is imposed to set the GUV in motion, such that it subsequently deforms by pressure and shear forces until it assumes a stationary state. The full numerical method is based on a phase-field method presented in [ 12 ] , with more details to be found in the methods section 4.1 . The used simulations parameters ( Q^{\prime}=0.04\,$\mathrm{\SIUnitSymbolMicro l}\text{\,}{\mathrm{s}}^{-1}$,L^{\prime}=20\,$\mathrm{\SIUnitSymbolMicro m}$,\eta^{\prime}=0.015\,$\mathrm{Pa}\text{\,}\mathrm{s}$ ) can be scaled to generalize results to arbitrary Q,L,\eta (see Sec. 2.2 ). Fig. 1 C shows an exemplary evolution of GUV deformation. The initially spherical surface is stretched (and transiently compressed) due to pressure and shear forces until the vesicle reaches a stationary bullet-shape, similar to the shapes observed for RT-DC measurements of GUVs (see Fig. 1 B) or cells [ 17 ] . To quantify deformation we use the measure D=1-{2\sqrt{A\pi}}/{P}, (1) where A denotes the area and P the perimeter of the two-dimensional image of the GUV shape,