Single arm interferometry to probe the scalar field dark matter

A. Capolupo, G.Pisacane, A. Quaranta, R. Serao · 2025

Read Single arm interferometry to probe the scalar field dark matter by A. Capolupo, G.Pisacane, A. Quaranta, R. Serao (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-13574.txt.

Introduction

Antonio Capolupo and co-authors propose a single-arm interferometer as a dark matter detector. If dark matter is a scalar field, its touch should nudge photons in a faint but real way. Standard interferometers use two arms; this design needs only one.

A coherent light beam passes through two squeezing operations set apart in space. The scalar field's interaction shifts the outgoing light state away from what free travel would give. That shift is the signal. Measuring it would both reveal the field and pin down its parameters. The setup offers a fresh, tabletop-scale route in the hunt for scalar dark matter.

Catalog record

CREATORA. Capolupo, G.Pisacane, A. Quaranta, R. Serao
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE16 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-13574

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Single arm interferometry to probe the scalar field dark matter A. Capolupo, G.Pisacane, A. Quaranta, R. Serao Abstract We analyze the interaction of photons with a scalar dark matter field ϕ \phi and we propose to use a single arm interferometer to reveal this interaction and constrain the parameters of the scalar dark matter model. By considering a beam of coherent light and two spatially separated squeezing operations, we show that the interaction of photons with scalar dark matter leads to an observable deviation in the outgoing light state, with respect to free evolution. Therefore the single arm interferometer may yield a novel revelation method for scalar dark matter. - Introduction : The nature of the dark sector of the universe is one of the main puzzles in modern cosmology. Dark energy is held responsible for the observed accelerated expansion of the universe, while dark matter is required to explain the gravitational binding of galaxies and galaxy clusters, as well as the rotation curve of spiral galaxies DM1 ; DM2 ; DM3 ; DM4 ; DM5 ; DM6 ; DM7 ; DM8 . Prominent dark matter candidates are axions and axion-like particles AX1 ; AX2 ; AX3 ; AX4 ; AX5 ; AX6 ; AX7 ; AX8 ; AX9 ; AX10 ; AX11 ; AXE1 ; AXE2 ; AXE3 ; AXE4 ; AXE5 ; AXE6 ; AXE7 ; AXE8 ; AXE9 ; AXE10 ; AXE11 ; AXE12 ; AXE13 ; AXE14 , supersymmetric particles susy1 ; susy2 ; susy3 ; susy4 ; susy5 ; susy6 ; susy7 ; susy8 ; susy9 ; susy10 ; susy11 ; susy12 ; susy13 ; susy14 ; susy15 ; susy16 ; susy17 , ultra-light scalar particles, known as scalar dark matter (SDM) DM10 ; SDM1 ; SDM2 ; SDM3 ; SDM4 ; SDM5 ; SDM6 ; SDM7 ; SDM8 ; SDM9 ; SDM11 , and fuzzy cold dark matter Fuzzy . Condensates from quantum field theory have also been suggested as possible contributions to the dark matter BSM1 ; BSM2 ; BSM3 ; BSM4 ; BSM5 ; BSM6 ; BSM7 . In this work we focus our attention on SDM. Several techniques have been proposed to test the SDM hypothesis. These include the use of highly sensitive optical cavities OP1 , gravitational wave detectors GW1 ; GW2 ; GW3 , and analyses of astrophysical phenomena that could provide indirect evidence for its existence AE1 ; AE2 . Constraints on SDM have been obtained in various experiments such as DAMA DAMA1 ; DAMA2 and precision atomic and molecular spectroscopy ATOM1 ; ATOM2 ; ATOM3 ; ATOM4 ; ATOM5 . Here, we present a novel approach to test the SDM model by means of single arm laser interferometry INT1 . The method is aimed at probing the phase shift and the intensity variation, experienced by a laser beam due to the interaction with the SDM. By considering laser light passing through two spatially separated squeezing operations, we show that the interaction between photons and scalar dark matter causes a detectable alteration in the outgoing laser state compared to its free evolution. This interaction cannot be revealed in standard interferometry experiments, since it affects the evolution of photons in the two arms equally and, therefore, no effect can be detected by phase difference analyses. In the following, we provide a discussion of the interaction between SDM and photons, then we introduce the interferometric setup, and compute the phase shift and the intensity variation due to SDM-photon interaction. Our numerical analysis shows that by using gravitational wave detectors, it is possible to verify the existence of the coupling between SDM and photons and, consequently, test the presence of scalar dark matter. - Scalar dark matter and photon interaction : The evolution of the scalar field \phi is described by the Klein-Gordon equation: \left(\Box+m_{\phi}^{2}\right)\phi=0 , where m_{\phi} represents the mass of the field. A key aspect of SDM’s phenomenology is its possible interaction with the photon field. This interaction can be described by an effective coupling term in the Lagrangian density 1 1 1 The total interaction Lagrangian when also the electron field is present is given by: \mathcal{L}_{\text{int}}=\frac{1}{4}\frac{\phi}{\Lambda_{\gamma}}F_{\mu\nu}F^{\mu\nu}-\frac{\phi}{\Lambda_{e}}\bar{\psi_{e}}\psi_{e} . Since we consider the propagation of the photon in vacuum, the last term is irrelevant, at least to lowest order. \mathcal{L}_{\text{int}}=\frac{\phi}{\Lambda_{\gamma}}F_{\mu\nu}F^{\mu\nu} , where F_{\mu\nu} is the electromagnetic field tensor and \Lambda_{\gamma} parametrizes the interaction strength. The interaction term affects the propagation of photons through regions permeated by SDM. The field \phi is assumed to have an extremely small mass ( \ll 1eV ) DM10 ; then its Compton wavelength \lambda_{c}=\frac{h}{mc} is very large, and the field \phi can be approximated as coherently oscillating classical field: \phi(t)\approx\phi_{0}\cos(\omega t + \theta) . Here, \theta is a random phase factor, \phi_{0}=\frac{1}{m_{\phi}}\sqrt{2\rho_{\text{local}}} is the amplitude of the field, with \rho_{\text{local}} local dark matter density, m_{\phi} is the mass of the scalar particle and \omega is the oscillation frequency, which is of the order of the mass of the SDM, \omega\simeq m_{\phi} ED1 ; ED2 ; ED3 . We consider natural units. We consider the radiation gauge, where the electromagnetic potential A^{\mu}=\left(A^{0},\vec{A}\right) satisfies the condition \vec{\nabla}\cdot\vec{A}=0 . Then, the Hamiltonian corresponding to the above Lagrangian \mathcal{L}_{\text{int}} is: \displaystyle\hat{H}_{\text{int}}=-\frac{4\phi(t)}{\Lambda_{\gamma}}\int d^{3}k\sum_{\lambda}\left|\vec{k}\right|\,N_{\vec{k}\lambda}, (1) where N_{\vec{k}\lambda}=a_{\vec{k}\lambda}^{\dagger}a_{\vec{k}\lambda} is the number operator of photons with momentum \vec{k} and polarization \lambda and a_{\vec{k}\lambda} is the annihilator. States with a definite number of photons are eigenstates of the Hamiltonian ( 1 ). Consequently, if the initial photon state is \ket{n_{\vec{k}\lambda}}=\frac{1}{\sqrt{n!}}\left(a_{\vec{k}\lambda}^{\dagger}\right)^{n}\ket{0} , the evolved state at time t , \ket{n_{\vec{k}\lambda}(t)} , in interaction picture is: \ket{n_{\vec{k}\lambda}(t)}=e^{-i\int_{0}^{t}\hat{H}_{\text{int}}(t^{\prime})\,dt^{\prime}}\ket{n_{\vec{k}\lambda}}=e^{iN_{\vec{k}\lambda}\,\delta_{k}(t)}\ket{n_{\vec{k}\lambda}}, (2) with phase shift \delta_{k}(t) given by: \delta_{k}(t)=\frac{4\left|\vec{k}\right|}{\Lambda_{\gamma}}\int_{0}^{t}\phi(t^{\prime})dt^{\prime}=\frac{4\left|\vec{k}\right|\phi_{0}}{\Lambda_{\gamma}\;\omega}\sin(\omega t)\;. (3) Note that the phase shift is independent on the polarization \lambda . In the following we shall consider polarized (fixed \lambda ) and monochromatic (fixed k ) light and we will omit the indices k,\lambda . To study the evolution of laser light, we analyze a coherent state \ket{\alpha}=e^{-\frac{|\alpha|^{2}}{2}}\sum_{n=0}^{\infty}\frac{\alpha^{n}}{\sqrt{n!}}\ket{n} . For coherent states, one has e^{iN\delta}\ket{\alpha}=e^{-\frac{|\alpha|^{2}}{2}}\sum_{n=0}^{\infty}\frac{\alpha^{n}e^{in\delta}}{\sqrt{n!}}\ket{n}=\ket{\alpha e^{i\delta}} , i.e. e^{iN\delta} rotates the complex amplitude \alpha by an angle \delta in the complex plane. - Phase measurement scheme : The phase shift in eq. ( 3 ) cannot be observed using a double-arm interferometer like the Michelson-Morley type, since the interaction Lagrangian \mathcal{L}_{\text{int}} influences both arms in the same way, leading to the cancellation of the phase shifts INT1 . However, a single-arm interferometer like the one described in refs. INT2 ; INT3 ; INT4 , can be utilized for our purposes. The single arm interferometer can be schematized as follows. First a squeezing operation S is performed on the laser beam. The beam then evolves along a path of length L , in vacuum, subject to the interaction with SDM. Later an anti-squeezing operation S^{-1} is applied and the laser light is detected, see Fig. 1 . If the beam does not undergo interaction with scalar fields, the initial state of the photons coincides, up to a global phase, with the final state since the beam is subjected to the action of S and S^{-1} . If, however, in the path L the photons interact with the scalar field, the final state will differ from the initial one. Thus, an eventual revelation of the difference between the initial

Read the complete text