Seismic Isolation of Optical Tables Using Piezo Actuators

Tailong Wang, Carl Blair, Ammar Al-Jodah, John Winterflood, Jian Liu, Alexander Adams, Aaron Goodwin-Jones, Chunnong Zhao, Li Ju · 2025

Read Seismic Isolation of Optical Tables Using Piezo Actuators by Tailong Wang, Carl Blair, Ammar Al-Jodah, John Winterflood, Jian Liu, Alexander Adams, Aaron Goodwin-Jones, Chunnong Zhao, Li Ju (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-13083.txt.

Introduction

Tailong Wang and colleagues describe an actively stabilized optical table that uses piezo actuators to cancel seismic vibration for precision measurement experiments. Seismic isolation is crucial for gravitational wave detectors, where ground motion can drown out faint signals. Their platform actuates along five degrees of freedom: three translations and two tip-tilt motions, while staying stiff in rotation about the vertical axis.

A seismometer senses the table's motion and feeds a control loop driving the piezo actuators. The system suppresses seismic noise strongly across roughly the half-hertz to one-hertz band, leaving residual horizontal motion at the nanometer scale at one hertz. The authors discuss limitations, notably tilt-to-translation coupling, that prevent actuation over the full desired range down to much lower frequencies. Tables like this are the unglamorous foundation of precision interferometry: every decibel of ground noise removed is sensitivity gained for the instruments mounted above.

Catalog record

CREATORTailong Wang, Carl Blair, Ammar Al-Jodah, John Winterflood, Jian Liu, Alexander Adams, Aaron Goodwin-Jones, Chunnong Zhao, Li Ju
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE24 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-13083

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Seismic Isolation of Optical Tables Using Piezo Actuators Preprint: AIP/123-QED Tailong Wang, Carl Blair, Ammar Al-Jodah, John Winterflood, Jian Liu, Alexander Adams, Aaron Goodwin-Jones, Chunnong Zhao, Li Ju Abstract Seismic isolation is crucial for gravitational wave detectors as it minimizes ground vibrations, enabling the detection of faint gravitational wave signals. An active seismic isolation platform for precision measurement experiments is described. The table features piezo actuation along five degrees of freedom: three translational actuations and two tip-tilt degrees of freedom along the horizontal axes. It is stiff in rotation about the vertical axes. A seismometer is used to sense table motion. Piezo actuators are used to suppress seismic noise with feedback control bandwidth of 0.3 to 3 Hz. Suppression levels ranging from 21 to 36 dB of seismic noise within the frequency range of 0.5 to 1.3 Hz are demonstrated, as measured by a witness seismometer on the table, with the suppression direction along the axis of the longitudinal translation of the suspended mirror on the table. The suppression results in 1 nm / Hz \mathrm{\mathrm{nm/\sqrt{Hz}}} residual horizontal motion at 1 Hz. Limitations such as tilt-to-translation coupling that prevent actuation over the desired range of 0.03 to 3 Hz are discussed. I Introduction Advanced gravitational wave detectors (GWDs), such as Advanced LIGO (aLIGO) The LIGO Scientific Collaboration 2015 , Advanced Virgo Acernese et al. 2015 , and KAGRA Aso et al. 2013 , require highly effective vibration isolation systems. These systems attenuate seismic noise by nine orders of magnitude at frequencies around 100 Hz, where gravitational waves (GW) are detected. Seismic isolation requirements out of the GWD frequency band are less well-defined. Less effective seismic isolation below 30 Hz, through many complicated channels, has not only limited the GW signal detection at lower frequencies, but also reduced detector duty cycle at LIGO Martynov, Hall et al. 2016 ; Buikema et al. 2020 ; Nguyen et al. 2021 . We aim to reduce microseismic noise and seismic excitation of suspension resonances at the Gingin High Optical Power Facility (HOPF). In this paper, we present the upgraded optical bench, which functions as a five-degree-of-freedom piezo active isolator for seismic isolation. The advantage of this system is the simplicity of the design. It is able to actuate heavy payloads with a compact and easily manufactured actuator. Optics are suspended by pendulum with a free-swinging resonant frequency around 0.5 Hz to suppress seismic noise at high frequencies. To mitigate the effects of microseismic noise and seismic excitation of suspension resonances, the target frequency band for our active isolator is from 0.03 Hz to 3 Hz. Herein we label it the active pre-isolator. The plan is to implement the active pre-isolator across all auxiliary optic tables, and use it as a pre-isolation stage for the University of Western Australia (UWA) Compact Vibration Isolation System (CVIS) Chin et al. 2006 ; Barriga et al. 2009 primarily to mitigate tilt coupling to the CVIS. The piezo pre-isolator is currently installed in two isolation tables for single pendulum stage suspended optics at the HOPF. Active pre-isolation systems are used in the Advanced LIGO Matichard et al. 2015 and VIRGO Blom et al. 2013 detectors as well as the AEI 10m-prototype Wanner et al. 2012 (AEI-SAS). The AEI-SAS uses a combination of low-frequency passive isolation and active control to achieve an impressive 40 dB suppression of horizontal table motion around 1 Hz. The frequency range between 0.08 Hz and 0.7 Hz relies on the L4C geophone and is limited by self-noise below 0.13 Hz Kirchhoff 2022 . In this frequency range, AEI-SAS provides a maximum of 30 dB translation suppression. At 1 Hz the AEI-SAS achieves 0.5 \mathrm{nm/\sqrt{Hz}} . Advanced LIGO uses three different active pre-isolation systems Matichard et al. 2015 : Hydraulic External Pre-Isolator (HEPI) Wen et al. 2014 , Basic Symmetric Chambers - Internal Seismic Isolation (BSC-ISI) and Horizontal Access Module - Internal Seismic Isolation (HAM-ISI) Kissel and Lantz . The HEPI system supports subsequent isolation stages and it is designed to provide one stage of very low frequency active isolation for the BSC or HAM chambers. They are currently used for alignment and tidal drift between chambers Matichard et al. 2015 . The ISI is supported by the HEPI system and is used to provide a second stage of pre-isolation Aston et al. 2012 . The performance of the combination of HEPI and BSC-ISI pre-isolation shows 60 dB suppression between 0.1 Hz and 1 Hz. It achieves nearly 60 dB suppression between 1 Hz and 10 Hz. The measurement in the relevant frequency between 0.9 Hz and 5 Hz is limited by GS13 (geophone) sensor noise Matichard et al. 2015 . The HAM-ISI system is similar to the Gingin system as it supports the auxiliary optics Aasi et al. 2015 . It is also pre-isolated by the HEPI, and the combined performance shows 60 dB suppression at 1 Hz and roughly 10 dB suppression at 0.25 Hz. Detailed performance analysis is in the paper Matichard et al. 2015 . Both the HAM-ISI and BSC-ISI achieve residual motion (measured by an in loop GS13) of 0.01 \mathrm{nm/\sqrt{Hz}} at 1 Hz. As a historical note, prior to HEPI, LIGO Livingston used a piezo pre-isolation system called PEPI Abbott et al. 2004 . This system only worked in one degree of freedom and achieved up to 20 dB suppression of resonant motion around 0.75 Hz and 1.3 Hz as witnessed by LIGO optical cavities. The External Injection Bench Seismic Attenuation System (EIB-SAS) on Advanced Virgo is used to damp the resonance of the EIB support structure Blom et al. 2013 . It uses both active and passive isolation similar to AEI-SAS. Located in air and carrying auxiliary optics, this system demonstrates good active damping performance, achieving 30-70 dB horizontal suppression between 2 Hz and 400 Hz. Compared to the active pre-isolation system described here, this system relies more heavily on passive isolation. The EIB-SAS does not require suppression in the micro-seismic frequency band Blom et al. 2015 , however some suppression is achieved in the translation degrees of freedom. The EIB-SAS achieved 10 \mathrm{nm/\sqrt{Hz}} at 1 Hz, however this is not in the target frequency band, it achieves about 0.1 \mathrm{nm/\sqrt{Hz}} at 10 Hz Blom 2015 . As a commercial comparison, the THORLAB active pre-isolation table Thorlabs 2018 achieves isolation above 2 Hz, reaching -24 dB at 5 Hz and -30 dB at 10 Hz horizontally. However, it lacks attenuation below its horizontal resonant frequency of approximately 1 Hz. In UWA basement labs residual motion on these tables is a few \mathrm{nm/\sqrt{Hz}} at 10 Hz. The active pre-isolator described in this paper provides competitive performance in the microseism frequency range with 36 dB suppression and a residual motion of 4 \mathrm{nm/\sqrt{Hz}} at 0.5 Hz, similar to the ISI at this frequency. While it does not fulfill requirements of tables presented above, it does provide a relatively simple solution that may be incorporated in other systems to provide isolation in this frequency range. In section II the apparatus is described. In section III the system has been experimentally demonstrated to achieve suppression levels ranging from 36 to 21 dB between 0.5 and 1.3 Hz. In section IV we describe performance

Read the complete text