Read Tabletop Lensless Imaging in the Extreme Ultraviolet with Reduced Radiation Dose by Sukyoon Oh, Monalisa Mallick, Thomas Siefke, Christian Spielmann (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-13075.txt.
Introduction
Hard ultraviolet imaging needs pricey optics and bright beams that can harm soft samples. Sukyoon Oh and co-authors built a lens-free tabletop scope that cuts the dose, in work from twenty twenty-five. Their light source is a compact lab unit, not a large facility beam. A ghost imaging trick uses known light patterns and math to rebuild the image.
Pattern sets plus sparse math gave sharp images even with few photons. Image quality scores beat base methods by a wide margin. The setup shrugs off lab shake that would blur lens systems. The team pitches the tool for gentle checks of soft matter and living samples, and for wider access to this light band.
Catalog record
| CREATOR | Sukyoon Oh, Monalisa Mallick, Thomas Siefke, Christian Spielmann |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 34 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2505-13075
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Tabletop Lensless Imaging in the Extreme Ultraviolet with Reduced Radiation Dose Sukyoon Oh, Monalisa Mallick, Thomas Siefke, Christian Spielmann Abstract High-resolution extreme ultraviolet (XUV) imaging remains limited by conventional approaches that require complex optics such as multilayer mirrors and zone plates. These methods are expensive, suffer from chromatic aberrations and narrow fields of view, and demand highly stable, coherent beam sources typically found only at large-scale facilities. Critically, the high photon flux they require often damages sensitive biological and soft-matter samples. We present a new solution: a lensless XUV microscopy platform combining a compact tabletop high-harmonic generation source with correlation-based ghost imaging. Our approach eliminates the need for complex optics, lowering system cost and dramatically improving resilience against lab-scale instabilities. Leveraging Hadamard patterns and compressive sensing algorithms, we achieve high-fidelity imaging even in low-photon environments, with a 400% improvement in structural similarity index compared to baseline methods. This confirms the feasibility of broadband, low-dose XUV imaging, enabling damage-minimized, non-destructive inspection for advanced materials and biological specimens, and establishes a new paradigm for accessible XUV microscopy. Keywords: Ghost Imaging, Single Pixel Imaging, Lensless Imaging, XUV microscopy, High Harmonic Generation 1 Introduction High-resolution imaging is a fundamental tool that enables groundbreaking inquiry across materials science, life sciences, and nanotechnology. However, conventional imaging techniques face a fundamental trade-off between resolution, system complexity, and sample damage. As defined by the Abbe criterion, resolution is fundamentally limited by the incident wavelength and the numerical aperture of the optical system, necessitating the use of short-wavelength radiation to resolve nanoscopic structures [ 1 ] . While the sub-keV regime, such as Extreme Ultraviolet (XUV) and Soft X-Ray (SXR) , offers the potential for significantly improved resolution, navigating these wavelengths presents technical and financial barriers that have limited access to advanced microscopy for many researchers [ 2 , 3 , 4 , 5 ] . To circumvent these limitations, alternative lensless imaging methods such as Coherent Diffraction Imaging (CDI) [ 6 , 7 ] and ptychography [ 8 , 9 , 10 , 11 ] have emerged. While these techniques can achieve high resolution, they typically rely on costly and complex optical components, such as multilayer mirrors or zone plates, or large-scale facilities like synchrotrons. Zone plates, for example, suffer from small fields of view [ 12 ] , chromatic aberrations, and fabrication challenges that fundamentally constrain resolution [ 13 ] . In addition, scanning-based actinic imaging approaches are inherently slow [ 14 ] , whereas multi-beam e-beam inspection methods, though fast, are non-actinic and cannot detect critical phase defects [ 15 ] . These methods also require high photon flux or electron exposure, often leading to radiation-induced damage in sensitive samples [ 7 , 10 , 16 ] . A promising alternative is Ghost Imaging (GI) , which has gained significant traction. GI employs a unique approach to image reconstruction by correlating a structured light pattern with a signal from a single-pixel detector [ 17 , 18 , 19 , 20 ] . This method inherently avoids the need for lenses and complex optics [ 21 ] . Because image formation relies on correlations rather than high photon flux, GI is a viable technique even with a low-flux, broadband source, making it ideally suited for the XUV regime [ 22 ] . Importantly, ghost imaging offers several conceptual advantages over current XUV /EUV metrology: (i) its optics-less operation circumvents the limitations of zone plates and multilayer mirrors, enabling larger effective fields of view without chromatic aberration; (ii) its correlation-based measurement allows for faster, parallel data acquisition compared to point-by-point scanning; (iii) its actinic capability ensures sensitivity to phase defects invisible to electron-based tools; and (iv) its low-dose illumination strategy minimizes radiation damage. In this study, we present a new paradigm for tabletop XUV microscopy by combining a compact High Harmonic Generation (HHG) source [ 23 , 24 ] with an optics-free ghost imaging technique. To our knowledge, this is the first tabletop platform to circumvent the need for both large-scale facilities and costly XUV optics for imaging. We systematically validate the feasibility of this platform and optimize its performance by comparing various illumination patterns and reconstruction algorithms. This paper demonstrates that our method successfully achieves micrometer-level resolution while reconstructing complex microscopic features without the need for lenses and XUV optics. Our research introduces a new, accessible solution that simplifies the imaging process and offers the inherent benefit of reduced dose requirements. This platform holds significant potential to democratize access to advanced XUV microscopy, opening the door for broader use in non-destructive analysis of delicate materials and real-time process monitoring across a wide range of fields. 2 Materials and Methods 2.1 Experimental Setup A crucial step in realizing the optics-free XUV microscopy is the choice of an XUV source. While large-scale facilities such as free-electron lasers and synchrotrons can generate XUV radiation, they are expensive and have limited accessibility. To address these challenges, we utilize a tabletop XUV source based on HHG in gases [ 25 ] . Figure 1: XUV Ghost Imaging Experimental Setup. (a) A schematic of the experimental setup, from high harmonic generation to image reconstruction. (b) The measured XUV beam profile. (c) The XUV spectrum, illustrating the effect of the XUV mask on photon counts. HHG is a highly nonlinear optical process that converts laser light into coherent radiation in the XUV and SXR spectral regions. The process begins when an intense femtosecond laser pulse interacts with a gas medium, typically noble gases such as argon, neon, or helium. The strong electric field of the laser ionizes the gas atoms via tunnel ionization, releasing free electrons. These electrons are subsequently accelerated by the oscillating laser field. As the laser field reverses direction, the electrons are driven back toward their parent ions, recombining and releasing their acquired kinetic energy in the form of high-energy photons. This results in a spectrum of high harmonics of the fundamental laser frequency [ 26 ] . The energy conversion efficiency from the Infrared (IR) to the XUV/ SXR region is typically very low, ranging from 10^{-6} to 10^{-8} . The HHG process in our experiment is driven by an ultrafast Ti:Sapphire laser system operating at a central wavelength of 800 nm with a repetition rate of 1 kHz. The laser delivers pulses with an average energy of 0.5 mJ and a duration of approximately 35 fs. These intense pulses are focused on an argon-filled nickel tube, which serves as the HHG generation medium. The generation chamber operates at a backing pressure of 70 mbar. A unique aspect of this setup is that the high-intensity laser self-drills a hole in the nickel tube, minimizing alignment issues and favoring phase-matching conditions, which allow the HHG process to occur efficiently. At the laser focus, the estimated Full Width Half Maximum (FWHM) of the IR beam is approximately 40 \mu m , which corresponds to an intensity of I=2\times 10^{15}~W/cm^{2} . This intensity is sufficient for generating high harmonics in argon [ 25 , 26 ] . An aluminum membrane filter with a thickness of 500 nm was used to eliminate residual infrared light. The resulting broadband XUV continuum has a photon flux of 1.2\times 10^{9} photons/s before passing through the XUV mask,