Demonstration of Advanced Timing Schemes in Time-Resolved X-ray Diffraction Measurements
Daniel Schmidt, David. v. Stetten, Michael Agthe, Arwen R. Pearson, Goddfrey .S. Beddard, Briony A. Yorke, Friedjof Tellkamp, Peter Gaal · 2025
Read Demonstration of Advanced Timing Schemes in Time-Resolved X-ray Diffraction Measurements by Daniel Schmidt, David. v. Stetten, Michael Agthe, Arwen R. Pearson, Goddfrey .S. Beddard, Briony A. Yorke, Friedjof Tellkamp, Peter Gaal (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-08502.txt.
Introduction
Daniel Schmidt and co-authors show a new timing method for X-ray tests that watch crystals change over time. Such tests need both fine time detail and a bright beam, which usually trade off against each other. Their method shapes the X-ray beam into patterned pulse trains with a solid-state picker tool.
Catalog record
| CREATOR | Daniel Schmidt, David. v. Stetten, Michael Agthe, Arwen R. Pearson, Goddfrey .S. Beddard, Briony A. Yorke, Friedjof Tellkamp, Peter Gaal |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2505-08502
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Demonstration of Advanced Timing Schemes in Time-Resolved X-ray Diffraction Measurements Daniel Schmidt, David. v. Stetten, Michael Agthe, Arwen R. Pearson, Goddfrey .S. Beddard, Briony A. Yorke, Friedjof Tellkamp, Peter Gaal Abstract keywords time-resolved, x-ray, synchrotron, Hadamard transform, structural dynamics † † affiliation: TXproducts UG (haftungsbeschränkt), Luruper Hauptstr. 1, 22547 Hamburg, Germany † † affiliation: European Molecular Biology Laboratory (EMBL), Notkestrasse 85, 22607 Hamburg, Germany † † affiliation: European Molecular Biology Laboratory (EMBL), Notkestrasse 85, 22607 Hamburg, Germany † † affiliation: University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany † † affiliation: School of Chemistry, University of Edinburgh, David Brewster Road, EH9 3FJ, UK † † affiliation: School of Chemistry, University of Leeds, Leeds, UK † † affiliation: Max Planck Institute for the Structure and Dynamics of Matter, Luruper Chaussee 149, 22761 Hamburg, Germany † † affiliation: Leibniz-Institut für Kristallzüchtung, Max-Born-Str. 2, 12489 Berlin, Germany † † affiliation: TXproducts UG (haftungsbeschränkt), Luruper Hauptstr. 1, 22547 Hamburg, Germany † † email: [email protected] 1 abstract We present time-resolved X-ray diffraction measurements using advanced timing schemes that provide high temporal resolution while also maintaining a high flux in the X-ray probe beam. The method employs patterned probe pulse sequences that are generated with the WaveGate solid-state pulse picker. We demonstrate the feasibility of our method at two different beamlines on millisecond and microsecond timescales. 2 Introduction Next-generation synchrotrons Shin 2021 present exciting opportunities for researchers across various fields, including biology, chemistry, life sciences, materials science, and engineering Chapman 2023 . A key advantage of these new sources is their improved ability to observe samples in situ within their natural environments and monitor their dynamics in operando . The relevant timescales for detecting structural dynamics typically range from picoseconds to microseconds. Such experiments are almost exclusively conducted using pump-probe schemes where a short stimulus, such as a laser pulse, excites the sample, and a subsequent probe pulse detects the transient state at a specific pump-probe delay. The temporal resolution of this scheme is generally limited by the duration of the probe pulse, typically around 100 ps at a synchrotron source Gaal et al. 2012 ; Enquist et al. 2010 . Using only one synchrotron pulse per excitation cycle ensures the best achievable time resolution but also reduces the photon flux because all other pulses within the excitation cycle are ignored. However, sample and measurement equipment are still exposed to the X-ray beam throughout the whole excitation cycle, which may cause saturation effects or even damage to the sample or to the measurement equipment Klureza et al. 2024 . Thus, when using the pump-probe method, researchers face a trade-off between temporal resolution and the sensitivity of their experiments. In this article, we discuss advanced timing schemes that overcome these limitations. Specifically, we present a method that employs patterned probe sequences derived from a Hadamard transform. The Hadamard transform is already applied in spectroscopy Jo et al. 2025 ; Ēriks Kupče and Freeman 2003 and microscopy Rousseau and Blouin 2012 ; Coufal et al. 1982 to maintain spectral or spatial resolution while increasing a measurement’s sensitivity Nelson and Fredman 1970 ; Beddard 2009 ; Beddard and Yorke 2016 . Researchers have already adapted it in the time domain successfully by imaging a rotating disc with an X-ray beam Cao et al. 2009 ; Klureza et al. 2024 . These results demonstrate the potential to significantly improve time-resolution, however, Hadamard time-domain measurements are not commonly performed due to the lack of flexibility in patterning the time structure of the X-ray beam. We employ a solid-state pulse picker ( WaveGate , TXproducts) to overcome this constraint. 3 Employing a Hadamard Transform for Time-Domain Measurements In this section we will briefly describe the working principle of the Hadamard transform specifically in the context of time-domain measurements. Consider the standard time-resolved measurement approach, i.e ., the pump-probe method. Let t denote the pump-probe delay axis. The pump-probe measurement divides this axis in n discrete time windows called delays t_{n} . For simplicity, assume that all t_{n} have the same duration \delta t_{n} although this is not a necessary condition. In the pump-probe scheme, each time window is filled with a probe pulse and a measurement, e.g ., a detector image W is recorded for each delay. Thus, the full dataset contains W_{n} measurements or detector images which represent the transient response R(t_{n})=R_{n} of the sample. Figure 1 a) depicts the pump-probe scheme in a simple scenario where the delay axis t is split into n=3 time windows. Each column in Figure 1 a) depicts a probe sequence, which in turn contains only one probe pulse. This means that only one time window in the probe sequence is filled. The probe sequences are represented by the following delay or M -matrix: \textbf{M}=\begin{bmatrix}1&0&0\\ 0&1&0\\ 0&0&1\\ \end{bmatrix} (1) The measurement matrix (which is an identity or unit matrix) represents the time-points in a traditional pump-probe experiment but we don’t tend to actively consider this fact in a pump-probe experiment. For the sake of demonstration, each detector image is obtained by multiplying the M -matrix with the transient sample response R , i.e ., \textbf{W}_{n}=\textbf{M}_{n,:}\times\textbf{R} ( S_{n,:} denotes the n-th row of the M -matrix). In reality, we obtain the detector images from measurements and use them to calculate the transient sample response. This is equivalent to the inverse operation \textbf{R}=\textbf{M}^{-1}\times\textbf{M} . Due to the symmetry of M the inverse operation is simple because \textbf{M}=\textbf{M}^{-1} . Consider now a different scheme for time-resolved measurement that employs probe sequences with more than one time window filled. The scheme is sketched in Figure 1 b). Intuitively, it may seem that this measurement cannot yield the same temporal resolution as the previously described pump-probe method. This is however not the case. Figure 1: Time-resolved measurement schemes: a) Pump-probe method: the delay axis is divided into time windows which are filled with probe pulses in consecutive measurements. Each measurement captures the transient state at one delay. b) Hadamard method: multiple windows on the delay axis are filled with probe pulses. The transient state at each delay (only delay t 1 is shown) can be retrieved during post processing using all measurements. To demonstrate this, we define a S -matrix which contains the probe sequences. Again, we choose a simple example with n=3 time windows. The S -matrix is derived from a Hadamard matrix Yorke et al. 2014 ; Sloane 1982 ; Harwit and Sloane 1979 and has the form \textbf{S}=\begin{bmatrix}1&1&0\\ 1&0&1\\ 0&1&1\\ \end{bmatrix} (2) The first measurement yields \textbf{S}_{1}=\textbf{S}_{1,:}\times\textbf{R}=(1\cdot\textbf{R}_{1})+(1\cdot\textbf{R}_{2})+(0\cdot\textbf{R}_{3}) , i.e ., it is a summation over a total of two probe pulses in windows 1 and 2. Again, we want to obtain the sample response R , thus we perform the inverse operation \textbf{R}=\textbf{S}^{-1}\times\textbf{W} , where \textbf{S}^{-1}=0.5\cdot\begin{bmatrix}1&1&-1\\ 1&-1&1\\ -1&1&1\\ \end{bmatrix} (3) For the first time window of the transient response we find \textbf{R}_{1}=\textbf{S}_{1,:}^{-1}\times\textbf{W}=(0.5\cdot\textbf{W}_{1})+(0.5\cdot\textbf{W}_{2})-(0.5\cdot\textbf{W}_{3}) . It is immediately evident that full measurement of all probe sequences is necessary to retrieve the transient state \textbf{R}_{1} . The same is true for any other transient state at any other delay. Figure 1 b) depicts graphically how the first delay point can be retrieved. To conclude this section, we want to point out the following general remarks on time-domain Hadamard measurements: