RM jitter: Wavelength-dependent Scatter in Rotation Measure Related to Faraday Complexity

Jeroen M. Stil · 2025

Read RM jitter: Wavelength-dependent Scatter in Rotation Measure Related to Faraday Complexity by Jeroen M. Stil (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-06460.txt.

Introduction

Jeroen Stil studies scatter in a radio measure caused by turbulent plasma between us and distant sources, in a solo work from 2025. The measure, called rotation measure, tracks how a plasma twists radio waves. Unseen fine structure in the plasma can make that measure vary with wavelength.

Stil names that scatter RM jitter. For a fixed plasma pattern, the range of values depends on which wavelengths a survey covers. The jitter does not depend on depth resolution, since it comes from true spread and wavelength based fading. Simulated samples matched the high scatter seen in faintly polarized sources. The effect can reveal the shape of plasma turbulence.

Catalog record

CREATORJeroen M. Stil
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE79 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-06460

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

RM jitter: Wavelength-dependent Scatter in Rotation Measure Related to Faraday Complexity Jeroen M. Stil Abstract The relation between Faraday Rotation Measure ( R ​ M RM ) and differential Faraday rotation by unresolved structure of a turbulent plasma is investigated for extragalactic radio sources. The R ​ M RM scatter of a sample of sources affected by turbulent Faraday screens with identical power spectra of Faraday depth structure, is referred to as R ​ M RM jitter. For fixed amplitude and slope of the power spectrum, the range of possible R ​ M RM s depends on the wavelength coverage of the survey. R ​ M RM jitter is independent of Faraday depth resolution as it results from the true Faraday depth dispersion and effects of wavelength-dependent depolarization. R ​ M RM jitter for a flux density limited sample is sensitive to the power law index γ \gamma of the power spectrum of Faraday depth structure. Assuming depolarization by a turbulent Faraday screen for all sources, a simulated flux-density-limited sample can reproduce the high R ​ M RM scatter found by Vanderwoude et al. [60] for sources that are less than 3 % 3\% polarized. R ​ M RM jitter of sources that are more than 3% polarized, is found to be smaller than the observed scatter, indicating that plasma other than the near-source environment dominates the R ​ M RM scatter for the more polarized sources. The significance of R ​ M RM jitter for applications of the R ​ M RM grid is discussed. I Introduction Faraday rotation is the only observational tool to probe galactic scale magnetic fields in astrophysical plasmas that are not illuminated by synchrotron emission of relativistic electrons, and it is one of the most powerful tools to map magnetic fields in plasmas where the magnetic field is illuminated by relativistic electrons. One of the most versatile data sets for investigation of cosmic magnetism at low and at high redshift is a Rotation Measure grid of extragalactic sources [ 8 ] . As Square Kilometre Array (SKA) 1 1 1 https://skao.int pathfinders have begun operations, and construction of the SKA is underway, connecting Faraday dispersion arising from turbulence in a plasma near the source with observable quantities such as fractional polarization and RM scatter is an important step in developing its key science goal Origin and Evolution of Cosmic Magnetic Fields [ 32 , 29 ] . A linearly polarized radio wave that travels through a magnetized plasma experiences rotation of the plane of polarization, traced by the polarization angle \theta , according to \theta-\theta_{0}=\phi\lambda^{2}, (1) where \theta_{0} is the polarization angle at the source, \lambda is the wavelength of the wave at the time it travels through the plasma, and \phi is the Faraday depth defined as \phi={e^{3}\over 2\pi m_{e}^{2}c^{4}}\int n_{e}B_{\|}dl, (2) with e the elementary charge, c the speed of light, m_{e} the mass of an electron, n_{e} the density of free electrons, and B_{\|} the component of the magnetic field along the line of sight. The total observable linearly polarized signal, expressed in terms of the complex linear polarization \mathcal{P}=q+iu , with q=Q/I and u=U/I the Stokes parameters for linear polarization divided by the total flux density, is [ 14 ] \mathcal{P}(\lambda^{2})=\int_{-\infty}^{\infty}\mathcal{F}(\phi)e^{2i\phi\lambda^{2}}d\phi, (3) where the complex Faraday dispersion function \mathcal{F}(\phi) represents the distribution of linearly polarized emission in \phi , integrated over the volume of space defined by the beam and the line of sight. In RM synthesis [ 14 ] , the sampling of \mathcal{P}(\lambda^{2}) by a survey is expressed in terms of a weight function W(\lambda^{2}) , which is zero where no measurements exist, and normalized to have its integral equal to 1. The inverse Fourier transform of the available data leads to the observed Faraday dispersion function, \tilde{\mathcal{F}}(\phi)=\int_{-\infty}^{\infty}\mathcal{P}(\xi)W(\xi)e^{-2i\phi\xi}d\xi, (4) with \xi=\lambda^{2} when \xi>0 and W(\xi)=0 when \xi\leq 0 [ 14 ] . The inverse Fourier transform of W is called the Rotation Measure Transfer Function ( RMTF ). The Rotation Measure RM is defined as the peak of |\tilde{\mathcal{F}}| , or its reconstructed equivalent after RM Clean [ 28 ] . The measurement error of RM for a source with polarized flux density that is a multiple M of the noise \sigma in polarization is \Delta_{M\sigma}={\Delta\phi_{\rm FWHM}\over 2M} (5) [ 14 ] , where \Delta\phi_{\rm FWHM} is the full width at half of the peak of |RMTF| . Surveys with a large bandwidth have in recent years reduced \Delta_{M\sigma} by an order of magnitude compared with older, narrow band surveys. This has greatly increased the scientific potential of observed scatter in RM , and the significance of understanding it in more detail. We also define the quantity \mathcal{R}={d\theta\over d\lambda^{2}}. (6) Although \mathcal{R} is often identified with RM , the definition of \mathcal{R} is monochromatic while the definition of RM involves, potentially, averaging over a wide wavelength range (Equation 4 ). This subtle difference is important here. RM synthesis is a non-parametric algorithm to create a polarization catalog from survey data. As such, it is the main analysis method in this paper. QU fitting [ 38 ] is a model-dependent alternative where \mathcal{P}(\lambda^{2}) is fitted with a physically motivated model. A popular model from Burn [15] and Sokoloff et al. [57] , \mathcal{P}(\lambda^{2})=|\mathcal{P}_{0}|\exp[-2\sigma_{\phi}^{2}\lambda^{4}]\exp[2i(\theta_{0}+\phi_{0}\lambda^{2})], (7) treats the Faraday rotation parameter \phi_{0} as independent from the Faraday depth dispersion, \sigma_{\phi} , which causes only depolarization. This model applies to depolarization by a foreground screen with structure much smaller than the scale of the beam, or the source, whichever is smaller. The net Faraday rotation could be from the screen itself, or another screen, as in the case of an extragalactic source behind the Milky Way [ 65 ] . Another popular model for QU fitting considers synchrotron emission within a plasma with uniform magnetic field and electron density, [ 57 , 44 ] \mathcal{P}=|\mathcal{P}_{0}|{\sin\Phi\lambda^{2}\over\Phi\lambda^{2}}\exp[2i(\theta_{0}+{1\over 2}\Phi\lambda^{2})], (8) where the parameter \Phi is the total Faraday depth of the source, and RM=\Phi/2 . Here we see a connection between RM and depolarization, as both result from the same integration of Faraday rotated emission along the line of sight. In both models, Equation 7 and Equation 8 , \mathcal{R} is a constant [ 57 ] , and RM=\mathcal{R} , except when complete depolarization occurs in Equation 8 . The interpretation of RM in terms of the total Faraday depth of the plasma is different for these models. Quantifying Faraday depth dispersion from survey data remains an area of active research [ 50 , 2 , 16 , e.g.] . Tribble [59] investigated depolarization by a turbulent screen that has structure on a range of scales, and derived an expression for depolarization that varies between the exponential form in Equation 7 and a power law dependence on wavelength. As radio lobes expand into the circumgalactic medium of the host galaxy, it is not unreasonable to expect that the energy injection scale for turbulence is roughly the scale of the lobes. Tribble [59] was mainly concerned with median depolarization properties, but also noted that the largest structures within the beam result in a certain amount of randomness. Shanahan et al. [53] showed the range of depolarization curves that can arise from different realizations of the same

Read the complete text