An Improved Approach to Estimate the Internal Resistance of a Battery During the HPPC Test

Prarthana Pillai ⋆†, Smeet Desai †, Krishna R. Pattipati ,, Balakumar Balasingam † · 2025

Read An Improved Approach to Estimate the Internal Resistance of a Battery During the HPPC Test by Prarthana Pillai ⋆†, Smeet Desai †, Krishna R. Pattipati ,, Balakumar Balasingam † (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-06410.txt.

Introduction

Prarthana Pillai and co-authors sharpen a standard battery test in their 2025 paper. Testers find the inner resistance of a battery by firing a current pulse and dividing the voltage shift by the current. That shortcut skips one fact: the pulse itself moves the resting voltage of the cell. The team show how big the error from that skip can be.

Their fix uses a new view of the test signal that lets them work out the resting voltage shift from the same data. The method needs no facts about charge level, cell size, age, or heat, so it fits many cell types. In simulator tests the error fell by 30 percent to more than 250 percent. On real round lithium cells in the standard pulse test, the fix cut the overread by up to 20 milliohms.

Catalog record

CREATORPrarthana Pillai ⋆†, Smeet Desai †, Krishna R. Pattipati ,, Balakumar Balasingam †
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE38 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2505-06410

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

An Improved Approach to Estimate the Internal Resistance of a Battery During the HPPC Test Prarthana Pillai ⋆†, Smeet Desai †, Krishna R. Pattipati ,, Balakumar Balasingam † Abstract This paper considers the problem of resistance estimation in electronic systems including battery management systems (BMS) and battery chargers. In typical applications, the battery resistance is obtained through an approximate method computed as the ratio of the voltage difference to the applied current excitation pulse or vice versa for admittance. When estimating the battery resistance, this approach ignores the change in the open circuit voltage (OCV) as a result of the excitation signal. In this paper, we formally demonstrate and quantify the effect of the OCV drop on the errors in internal resistance estimation. Then, we propose a novel method to accurately estimate the internal resistance by accounting for the change in OCV caused by the applied current excitation signal. The proposed approach is based on a novel observation model that allows one to estimate the effect of OCV without requiring any additional information, such as the state of charge (SOC), parameters of the OCV-SOC curve, and the battery capacity. As such, the proposed approach is independent of the battery chemistry, size, age, and the ambient temperature. A performance analysis of the proposed approach using the battery simulator shows significant performance gain in the range of 30% to more than 250% in percentage estimation error. Then, the proposed approach is applied for resistance estimation during the hybrid pulse power characterization (HPPC) of cylindrical Li-ion battery cells. Results from tested batteries show that the proposed approach reduced the overestimated internal resistance of the batteries by up to 20 m Ω \Omega . I Introduction Electric vehicles (EVs) employ lithium-ion batteries due to their high energy density [ 1 ] and low rate of self-discharge [ 2 ] . Battery management system (BMS) plays a critical role in the reliable operation of batteries in EV [ 3 ] . The BMS controls the voltage limits of the battery, provides protection from overcharging and over-discharging, and estimates crucial parameters like state of charge (SOC), state of health (SOH), and state of power (SOP) of the battery [ 4 ] . Open circuit voltage (OCV) and internal resistance of the battery are crucial for estimating the SOC, SOH, and SOP, and must be accurately estimated for effective battery management. Electrical resistance is defined as the property of any material describing its opposition to the flow of electrical current. The resistance of any material is defined using Ohm’s law, which states that resistance is the ratio of the voltage to the current. The current and voltage quantities can be obtained by controlled injection of one and the measurement of the other, i.e., voltage can be applied and current can be measured (potentiostatic measurements) or current can be applied and voltage can be measured as response (galvanostatic measurements). It is a fundamental quantity used in circuit design across multiple industries for its usage as a measure of material property, quality, reliability and safety. In material sciences, resistance measurement is used for insulation and damage detection [ 5 ] . In the medical field, impedance measurement is useful for biomedical devices and live tissues. Bioimpedance measurement involving live tissues follows stringent standards to maintain current ranges between 100mA and 100 \mu A [ 6 ] , with further restrictions for heart patients [ 7 ] . Accurate impedance monitoring is also crucial for motor devices, ear implants, and cell monitoring to prevent harmful voltage levels [ 8 ] . In the automotive industry, battery resistance estimation has important applications. One such example is in the estimation of the SOH of a starter battery of the internal combustion engines. These batteries are typically made of lead-acid chemistry and measure either 6V or 12V. To measure their SOH, a high current load (typically 100A) is applied to the battery and the voltage drop across the terminals is measured [ 9 , 10 , 11 , 12 , 13 ] . The amount of voltage drop serves as a measure of the SOH; here, the SOH is a combined measure of both the power fade and capacity fade of the starter battery. In battery electric vehicles, the battery pack powers the entire vehicle operation. As such, more detailed battery health monitoring is necessary; here, the power fade and capacity fade are separately monitored. Other circuit diagnostics in electrical energy storage systems are performed using a variety of instruments, varying in their precision and measurement capabilities. Some instruments include multimeters, Ohmmeters, Wheatstone and Kelvin Bridges, micro and meg-ohmmeters, RLC meters [ 14 ] . In many of these measurement systems for batteries, a single value or frequency-dependent resistance measurement is obtained in the steady-state, directly or indirectly using the measured voltage drop. The focus of the present work is towards improving the accuracy of resistance measurement in batteries and other similar energy storage systems. Electrical energy storage systems experience a voltage bias when controlled voltage/current is injected for the resistance/impedance measurement. This means that the current/voltage recorded in response to the supplied injection is affected by this bias and this bias affects the computed resistance. The voltage bias recorded in the response of the battery to injected current/voltage is attributed to its complex electrochemical and nonlinear behaviour. The non-linear battery behavior is modelled using electrical equivalent circuit models (ECM) consisting of resistive, capacitive, and inductive components. The values of the ECM components determine the dynamic behaviour of the battery. Further, ECM modelling is crucial for the management of BMS functionalities. An evaluation of 14 ECMs is done in [ 15 ] , detailing their advantages and complexities. High-fidelity ECMs may accurately represent the battery behavior; however, estimating their parameters may be challenging. On the other hand, the parameters of low-fidelity ECMs can be easily estimated [ 16 ] . Based on the domain of estimation, existing ECM parameter identification can be categorized into frequency, time-domain and standardized characterization methods. Frequency-domain approaches employ sinusoidal signals of frequencies ranging from few mHz to several kHz [ 17 ] to obtain the parameters of the selected ECM of a battery. Electrochemical Impedance Spectroscopy (EIS) is a widely used method in BMS research [ 18 ] . In EIS, a small amplitude current or voltage of varying frequencies is applied to the battery [ 19 ] ; the measured response of the battery is converted into the frequency domain using discrete Fourier transform [ 20 ] and the impedance spectrum is obtained in the frequency domain, later used by algorithms for the estimation of ECM parameters [ 21 , 22 , 23 ] . Even though EIS is the most widely used method for impedance estimation, it is disadvantaged by the fact that it requires a long measurement time. Also, EIS approaches require high-precision hardware capable of data measurement at a wide range of frequencies [ 24 ] . Time-domain approaches use a pulse current to measure the instantaneous voltage response of the battery. Similar to the frequency-domain approach, the parameters of selected ECM are captured using various algorithms in an online or offline manner. Online parameter estimation updates the parameters throughout the operation, while offline

Read the complete text