Read Determination of the absorbed dose in the brain with DICOM images using GATE/GEANT4 and MATLAB by Walter Sabalza-Castillejo, Miguel Martín-Landrove (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2505-01970.txt.

Description

Walter Sabalza-Castillejo and Miguel Martin-Landrove compute the radiation dose a brain absorbs during PET imaging, in this 2025 paper. Their method couples a Monte Carlo simulator with patient scan images. A tiny cube of tissue laced with tracer serves as the test source.

The team tracked how positrons wander from the source cube into its neighbors, tallying dose from both gamma and beta rays. Math on the image cubes then sharpens the dose picture. Results are checked against standard dose guides from two bodies. The test scans come from a hospital scanner in Caracas. The aim is dose maps tuned to the single patient, not the average body.