Noise limits for dc SQUID readout of high- Q Q resonators below 300 MHz

V. Ankel, C. Bartram, J. Begin, C. Bell, L. Brouwer, S. Chaudhuri, John Clarke, H.-M. Cho, J. Corbin, W. Craddock, S. Cuadra, A. Droster, M. Durkin, J. Echevers, J. T. Fry, G. Hilton, K. D. Irwin, A. Keller, R. Kolevatov, A. Kunder, D. Li, N. Otto, K. M. W. Pappas, N. M. Rapidis, C. P. Salemi, D. Sc · 2025

Read Noise limits for dc SQUID readout of high- Q Q resonators below 300 MHz by V. Ankel, C. Bartram, J. Begin, C. Bell, L. Brouwer, S. Chaudhuri, John Clarke, H.-M. Cho, J. Corbin, W. Craddock, S. Cuadra, A. Droster, M. Durkin, J. Echevers, J. T. Fry, G. Hilton, K. D. Irwin, A. Keller, R. Kolevatov, A. Kunder, D. Li, N. Otto, K. M. W. Pappas, N. M. Rapidis, C. P. Salemi, D. Sc (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-20398.txt.

Introduction

A large team of physicists set the noise floor for reading high grade resonators with SQUIDs. Their paper, from twenty twenty-five, deals with cryogenic resonators below a set radio band. SQUIDs are the most keen magnetic sensors known, used here as the first read stage. The team used built first stage SQUIDs whose acts match a classic theory well. They were tied straight to the resonators.

Data from a prototype second stage array adds to the map. Such readouts serve hunts for dark matter and other faint signs. Readers in low heat physics get firm noise bounds for a core read chain. The bounds tell how deep a hunt can see before sensor noise rules.

Catalog record

CREATORV. Ankel, C. Bartram, J. Begin, C. Bell, L. Brouwer, S. Chaudhuri, John Clarke, H.-M. Cho, J. Corbin, W. Craddock, S. Cuadra, A. Droster, M. Durkin, J. Echevers, J. T. Fry, G. Hilton, K. D. Irwin, A. Keller, R. Kolevatov, A. Kunder, D. Li, N. Otto, K. M. W. Pappas, N. M. Rapidis, C. P. Salemi, D. Sc
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE69 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-20398

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Noise limits for dc SQUID readout of high- Q Q resonators below 300 MHz V. Ankel, C. Bartram, J. Begin, C. Bell, L. Brouwer, S. Chaudhuri, John Clarke, H.-M. Cho, J. Corbin, W. Craddock, S. Cuadra, A. Droster, M. Durkin, J. Echevers, J. T. Fry, G. Hilton, K. D. Irwin, A. Keller, R. Kolevatov, A. Kunder, D. Li, N. Otto, K. M. W. Pappas, N. M. Rapidis, C. P. Salemi, D. Schmidt, M. Simanovskaia, J. Singh, P. Stark, C. D. Tesche, J. Ullom, L. Vale, E. C. van Assendelft, K. van Bibber, M. Vissers, K. Wells, J. Wiedemann, L. Winslow, D. Wright, A. K. Yi, B. A. Young Abstract We present the limits on noise for the readout of cryogenic high- Q Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche-Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high- Q Q resonator over this frequency range, and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction-imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which will use dc SQUID s in this frequency range. SM Standard Model QED quantum electrodynamics QCD quantum chromodynamics BSM beyond the standard model DM dark matter CDM cold dark matter GUT grand unification theory WIMP weakly interacting massive particle SHM Standard Halo Model ppm part-per-million ppb part-per-billion ADM axion dark matter ALP axion-like particle PQ Peccei-Quinn PQWW Peccei-Quinn-Wilczek-Weinberg KSVZ Kim-Shifman–Vainshtein–Zakharov DFSZ Dine–Fischler–Srednicki–Zhitnitsky LSW light shining through wall DP dark photon DR dilution refrigerator PT pulse tube OFHC oxygen-free, high-conductivity TE transverse electric TM transverse magnetic TEM transverse electromagnetic MQS magneto-quasistatic SQL standard quantum limit QND quantum non-demolition DFT discrete Fourier transform FFT fast Fourier transform SNR signal-to-noise ratio PSD power spectral density FOM figure of merit SQUID superconducting quantum interference device SQL standard quantum limit Preprint: AIP/123-QED I Introduction SQUIDs have been used as highly sensitive magnetic flux and current amplifiers for sixty years [ 1 , 2 ] ; dc SQUID s are well established in applications ranging from fundamental physics to prospecting and medical imaging. In this paper we focus on their use to read out high quality factor ( Q ), low-temperature resonators at very high frequencies (VHF) and below ( f<300 MHz). Resonant applications include Weber bars for gravitational wave detection [ 3 ] , low-field nuclear magnetic resonance (NMR) [ 4 ] , magnetic resonance imaging (MRI) [ 5 ] measurements, and searches for light-dark-matter candidates including quantum chromodynamics (QCD) axions and hidden photons [ 6 , 7 , 8 , 9 , 10 , 11 ] . The sensitivity of these applications and experiments directly depends on the noise of the SQUID readout chain. Weak coupling between a high- Q , low-temperature resonator and the first-stage dc SQUID can be optimal. In this weak-coupling regime, optimized dc SQUID performance is consistent with the seminal work by Tesche and Clarke [ 12 , 13 , 14 ] (hereafter referred to as TC). This theoretical analysis established the conditions to optimize the single-stage dc SQUID noise performance and allows us to calculate the imprecision and backaction noise, as well as their correlations, at optimized conditions. The imprecision noise is defined as the noise when no input circuit is attached and the input terminals are open, in which case there can be no backaction-current response of the input circuit (and hence no backaction noise contribution on the output). When coupled to an input circuit, the backaction noise term presents as a voltage applied to the input circuit, driving an input current signal that is partially correlated with the imprecision current noise in the SQUID. We typically refer all noise contributions to the SQUID input. This work lays out the noise limits for a SQUID-based amplifier chain coupled to a resonator (see Fig. 1 ) under the conditions of weak input coupling, high frequency bandwidth, and low dynamic range (thus relaxing the need for fast flux feedback). The full system noise comprises contributions from the first-stage dc SQUID as well as from second-stage SQUID circuits and downstream electronics, including those at room temperature. We present gain, impedance, and noise data measured for a prototype second-stage SQUID circuit for this application. We also discuss several options for follow-on amplification, including commercial options at cryogenic and room temperatures as well as a custom, high-bandwidth amplifier based on previously published work. We finally combine the previously published theoretical and experimental analysis of first-stage SQUIDs with the second-stage data and follow-on amplifier specifications to consider the full system noise that can be achieved in weakly coupled resonators. The noise performance of this SQUID amplifier chain can be optimized for different applications. In this work, we initially compute the on-resonance noise match conditions to minimize the dc SQUID noise temperature and optimize the resulting on-resonance performance. We also analyze the optimal noise temperature that can be achieved by a dc SQUID coupled to an arbitrary complex input impedance. We show that this noise temperature is equivalent to that which can be achieved by a single dc SQUID coupled to an LC resonator that has been optimally detuned to minimize noise temperature, as computed by Clarke [ 14 ] . This result shows, for the first time, that an LC resonator can achieve the optimum noise match to a dc SQUID, albeit in a narrow bandwidth. We further extend this analysis to include the noise contributions from follow-on amplifier stages. Applications, including wavelike dark matter searches, benefit from optimizing the noise match to maximize the sensitivity of a wide frequency scan, rather than maximizing sensitivity on resonance or in a narrow bandwidth around a particular detuned frequency. The amplifier chain described in this paper, while applicable to a broad range of resonant applications, is well suited to resonant, low-mass axion dark matter searches such as the Dark Matter Radio experiments, specifically DMRadio -m 3 . Axion signals can be captured in resonant circuits, but to detect this tiny signal, the resonators must be optimally coupled to low-noise amplifiers. The expected signals have a small dynamic range; however, the signal frequency is unknown, so the amplifier must be able to operate over a wide bandwidth of resonator frequency tuning ( 5 – 200\, MHz in the case of DMRadio -m 3 ) [ 6 , 7 ] . Figure 1: The full SQUID amplifier chain coupled to an input resonator with complex impedance Z_{\rm res} via input inductor L_{\rm in} . S_{\rm VV} is the PSD of the backaction voltage noise acting on the first-stage input. S_{\rm II} is the PSD of the 1st-stage dc SQUID imprecision noise referred to a current in the input, and S_{\rm

Read the complete text