Read Analytical solutions for the Extracellular-Membrane-Intracellular model by Carlos Ballesteros, Alexei Cheviakov, Raymond J. Spiteri (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-19960.txt.

Introduction

Heart spark sums oft blur the walls twixt cells, yet a new frame keeps each zone apart: out space, wall, and in space. Carlos Ballesteros, Alexei Cheviakov, and Raymond Spiteri stock that frame with hand made test sums in a 2025 study. True sums let a crew check a sim's truth ere they trust its tales.

One set fits a lone flat cell in ring sums. A twin set fits two round cells in three spans. A made set fits a crowd of cells on a grid. Each set is then run through a wall split sim of known build. The hand sums match the sim runs mark by mark, so the frame's sim earns a clean bill for ill heart work.

Catalog record

CREATORCarlos Ballesteros, Alexei Cheviakov, Raymond J. Spiteri
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE51 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-19960

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Analytical solutions for the Extracellular-Membrane-Intracellular model Carlos Ballesteros, Alexei Cheviakov, Raymond J. Spiteri Abstract The Extracellular-Membrane-Intracellular (EMI) model is a novel mathematical framework for cardiac electrophysiology simulations. The EMI model provides a more detailed description of the heart’s electrical activity compared to traditional monodomain and bidomain models, potentially making it better-suited for understanding the electrical dynamics of the heart under pathological conditions. In this paper, we derive and verify several analytical solutions for the EMI model. Specifically, we obtain a family of solutions for a single two-dimensional cell in polar coordinates and for a pair of coupled three-dimensional cells in spherical coordinates. We also introduce a manufactured solution for N N three-dimensional cells in Cartesian coordinates. To verify the analytical solutions, we conduct numerical experiments using the mortar finite element method combined with operator splitting. The results demonstrate that the analytical solutions are effective for verifying the accuracy of numerical simulations of the EMI model. 1 Introduction Mathematical models of cardiac electrophysiology are highly useful in understanding the propagation of electrical signals in the heart tissue. These models are used to study the effects of various physiological and pathological conditions, such as cardiac arrhythmias, on the electrical activity of the heart and to develop new therapeutic strategies for their treatment. The most popular cardiac models are the monodomain and bidomain, which work well to simulate healthy tissue. However, these models have some limitations when it comes to simulating an unhealthy heart. To overcome these limitations, a new model called the extracellular-membrane-intracellular (EMI) model was developed [ 1 ] . This model considers the tissue as a collection of individual cells connected to each other, which is more realistic than the monodomain and bidomain models, where the tissue is considered as a single homogenized physical region. Simulating heart tissue at the cellular level using the EMI model is computationally intensive due to the complexity and scale of the problem. This challenge has driven the development or implementation of various numerical methods, especially spatial discretization methods, such as the boundary element method [ 2 ] , cut finite element method [ 3 ] , mortar finite element method, and H(div) finite element method [ 1 ] . These implementations have, in turn, motivated the search for analytical solutions to validate the accuracy and performance of the numerical methods. To this end, researchers often opt for the application of manufactured solutions to simulate a single cell [ 1 , 3 , 4 , 5 ] , which provides a useful tool for convergence analysis. However, these solutions may not fully capture realistic scenarios. In this work, we provide a detailed derivation of a family of analytical solutions for the EMI model that is more general and realistic than previous analytical solutions for one and two cells. We also introduce a manufactured solution for N three-dimensional cells. We numerically implement the EMI model using operator splitting in conjunction with the mortar finite element method to simulate simple examples from our solution family for one and two cells, as well as our manufactured solution, in order to verify the utility of the analytical solutions for benchmarking. The paper is organized as follows. In Section 2 , we provide a detailed description of the EMI model. In Section 3 , we derive the family of analytical solutions. In Section 4 , we describe the numerical implementation of the EMI model, and in Section 5 , we present the numerical results for some simple solutions. Finally, in Section 6 , we summarize our conclusions and outline directions for future work. 2 The Extracellular-Membrane-Intracellular model The Extracellular-Membrane-Intracellular (EMI) model, also known as the cell-by-cell model [ 4 , 2 ] was formally introduced by Tveito et al. [ 1 ] in 2017. Nonetheless, the model had been the subject of study for many years prior to that. [ 6 , 7 , 8 ] . The model is based on three physical spaces: the intracellular space, the intracellular-extracellular membrane (or cell membrane) space, and the extracellular space. The tissue is represented as a collection of cells spread across the extracellular space that communicate with one another via their membranes. 2.1 Governing equations The complete mathematical description of the EMI model [ 1 , 9 ] is presented as follows. Let \Omega_{e} be a bounded domain representing the extracellular space, in which N cells are embedded, with its boundary denoted by \partial\Omega_{e} . For each cell k , the intracellular space is represented by the domain {\Omega_{i}^{([)}}k] with its boundary \partial{\Omega_{i}^{([)}}k] . The intersection between the boundary of cell k and the boundary of the extracellular domain represents the membrane of the cell, denoted by {\Gamma_{i}^{\,([)}}k]:=\partial{\Omega_{i}^{([)}}k]\cap\partial\Omega_{e} , while the intersection between the boundaries of two different cells k and \ell , \Gamma^{\,([)}k,\ell]:=\partial{\Omega_{i}^{([)}}k]\cap\partial{\Omega_{i}^{([)}}\ell] , represents a gap junction. The outer boundary of the extracellular space is denoted by \Gamma_{e} . Figure 1 shows a two-dimensional configuration with four cells and the associated domains to illustrate the domains of the EMI model. Figure 1 : Configuration of a two-dimensional domain with four cells (purple) surrounded by extracellular space (blue) with gap junctions (orange) [ 1 ] . The intracellular potential {\Omega_{i}^{([)}}k] in the intracellular space of cell k is denoted by {u_{i}^{([)}}k] , and the extracellular potential in the extracellular space \Omega_{e} is denoted by u_{e} . The transmembrane potential of a cell k is divided into two parts, the transmembrane potential across the membrane, v^{(k)} , which is defined as \displaystyle v^{(k)} \displaystyle={u_{i}^{([)}}k]-u_{e}, \displaystyle\text{on ${\Gamma_{i}^{\,([)}}k]$}, (1) and the transmembrane potential across the gap junctions {w^{([)}}k,\ell] , which for an adjacent cell l , is defined as \displaystyle{w^{([)}}k,\ell] \displaystyle={u_{i}^{([)}}k]-{u_{i}^{([)}}\ell] \displaystyle\text{on $\Gamma^{\,([)}k,\ell]$}. (2) In each intracellular space {\Omega_{i}^{([)}}k] and the extracellular domain \Omega_{e} , the intracellular and extracellular potentials satisfy \displaystyle\nabla\cdot(\sigma_{i}\nabla{u_{i}^{([)}}k]) \displaystyle=0, \displaystyle\qquad\text{in ${\Omega_{i}^{([)}}k]$}, (3a) \displaystyle\nabla\cdot(\sigma_{e}\nabla u_{e}) \displaystyle=0, \displaystyle\qquad\text{in $\Omega_{e}$}, (3b) where the parameters \sigma_{i} and \sigma_{e} represent the conductivities of the intracellular and extracellular spaces, respectively, where for simplicity we assume \sigma_{i} is not cell-dependent. Furthermore, on each membrane {\Gamma_{i}^{\,([)}}k] and gap junction \Gamma^{\,([)}k,\ell] , the transmembrane potentials v^{(k)} and {w^{([)}}k,\ell] satisfy \displaystyle{C_{m}^{([)}}k]\frac{\mathop{\mathrm{\mathstrut\partial}}\nolimits\!v^{(k)}}{\mathop{\mathrm{\mathstrut\partial}}\nolimits\!t} \displaystyle={I_{m}^{([)}}k]-{I_{\text{ion}}^{([)}}k], \displaystyle\text{on ${\Gamma_{i}^{\,([)}}k]$}, (4a) \displaystyle{I_{m}^{([)}}k]=(\sigma_{e}\nabla u_{e})\cdot\hat{\bf n}_{e} \displaystyle=-(\sigma_{i}\nabla{u_{i}^{([)}}k])\cdot{\hat{\bf n}_{i}^{([)}}k], \displaystyle\text{on ${\Gamma_{i}^{\,([)}}k]$}, (4b) \displaystyle{C_{m}^{([)}}k,\ell]\frac{\mathop{\mathrm{\mathstrut\partial}}\nolimits\!{w^{([)}}k,\ell]}{\mathop{\mathrm{\mathstrut\partial}}\nolimits\!t} \displaystyle={I_{m}^{([)}}k,\ell]-I^{([)}_{\text{gap}}k,\ell], \displaystyle\text{on $\Gamma^{\,([)}k,\ell]$}, (4c) \displaystyle{I_{m}^{([)}}k,\ell]=(\sigma_{i}\nabla{u_{i}^{([)}}k])\cdot{\hat{\bf n}_{i}^{([)}}k] \displaystyle=-(\sigma_{i}\nabla{u_{i}^{([)}}\ell])\cdot{\hat{\bf n}_{i}^{([)}}\ell], \displaystyle\text{on $\Gamma^{\,([)}k,\ell]$}, (4d) where the parameter {C_{m}^{([)}}k] is the capacitance of the membrane {\Gamma_{i}^{\,([)}}k] per unit area, the ion currents {I_{m}^{([)}}k] and {I_{\text{ion}}^{([)}}k] are currents across the membrane {\Gamma_{i}^{\,([)}}k] , and {\hat{\bf n}_{i}^{([)}}k] is the outward unit normal vector to \partial{\Omega_{i}^{([)}}k] . The parameter {C_{m}^{([)}}k,\ell] is the capacitance of the gap junction \Gamma^{\,([)}k,\ell] , {I_{m}^{([)}}k,\ell] is the ion current across the gap junction \Gamma^{\,([)}k,\ell] , and I^{([)}_{\text{gap}}k,\ell] is the ion current due to the transmembrane potential {w^{([)}}k,\ell] at the gap junction. We note that at the gap junction \Gamma^{\,([)}k,\ell] , the normal vectors {\hat{\bf n}_{i}^{([)}}k] from \partial{\Omega_{i}^{([)}}k] and {\hat{\bf n}_{i}^{([)}}\ell] from \partial{\Omega_{i}^{([)}}\ell] satisfy {\hat{\bf n}_{i}^{([)}}k]=-{\hat{\bf n}_{i}^{([)}}\ell] . Let {t_{[}}0],t_{\text{f}}>0 be such that {t_{[}}0]<t_{\text{f}} . The extracellular potential u_{e} is subject to either a Dirichlet boundary condition on \Gamma_{e}\times[{t_{[}}0],t_{\text{f}}] , \displaystyle u_{e} \displaystyle=u_{\text{app}}, (5) or a Neumann boundary condition \displaystyle(\sigma_{e}\nabla u_{e})\cdot\hat{\bf n}_{e} \displaystyle={I_{\text{app}}}. (6) A cell model is added to the system to couple the transmembrane potentials v^{(k)} and {w^{([)}}k,\ell] with the ion currents {I_{\text{ion}}^{([)}}k] and I^{([)}_{\text{gap}}k,\ell] .

Read the complete text