St4DeM A software suite for multi-modal 4D-STEM acquisition techniques

Toni Uusimäki, Cheuk-Wai Tai, Tom Willhammar, Thomas Thersleff, Hasan Ali, Seda Ulusoy, Meltem Sezen, Bora Derin · 2025

Read St4DeM A software suite for multi-modal 4D-STEM acquisition techniques by Toni Uusimäki, Cheuk-Wai Tai, Tom Willhammar, Thomas Thersleff, Hasan Ali, Seda Ulusoy, Meltem Sezen, Bora Derin (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-19762.txt.

Introduction

Toni Uusimäki and co-authors present a software suite for advanced electron microscopy in a 2025 paper. The suite, St4DeM, runs inside Digital Micrograph, a platform used in microscopy labs worldwide. It serves the 4D-STEM method, which logs a diffraction pattern at each probe point of a sample scan.

Tools cover 4D-STEM capture, ptychography, spectrum imaging by two energy methods, and tomography, plus basic views and alignment of 4D data. Phase contrast checks are built in as well. By joining tomography with 4D-STEM and spectrum data, the suite can gather and probe data sets with seven dimensions in all.

Catalog record

CREATORToni Uusimäki, Cheuk-Wai Tai, Tom Willhammar, Thomas Thersleff, Hasan Ali, Seda Ulusoy, Meltem Sezen, Bora Derin
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE27 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-19762

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

St4DeM A software suite for multi-modal 4D-STEM acquisition techniques Toni Uusimäki, Cheuk-Wai Tai, Tom Willhammar, Thomas Thersleff, Hasan Ali, Seda Ulusoy, Meltem Sezen, Bora Derin Abstract A suite of acquisition applications related to the 4D-STEM technique is presented as a software package written within the Digital Micrograph environment, which is a widely used software platform in worldwide electron microscopy laboratories. The 4D-STEM technique allows the acquisition of diffraction patterns at each electron probe position in a scanning transmission electron microscope map. This suite includes 4D-STEM acquisition, ptychography, EELS/EDS spectrum imaging, tomography and basic virtual visualization and alignment methods on 4D data including incoherent differential phase contrast analysis. By integrating electron tomography with 4D-STEM and EELS SI, St4DeM enables the acquisition and analysis of 7-dimensional data. I Introduction The unequivocal imaging resolution provided by the aberration-corrected scanning transmission electron microscope (STEM) Pennycook and Nellist 2011 , and its ability to study nanoscale phenomena locally by converging the electron beam onto the sample at subatomic probe sizes Krivanek et al. 2015 have made it an unmatched technique in the field of material science Wu et al. 2018 . Furthermore, accompanied by the computing power and memory of modern computers and fast direct electron counting cameras Levin 2021 , STEM can be used not just to acquire a one-dimensional intensity but simultaneously to record a 2D converged beam electron diffraction (CBED) image at every probe position within the scan. Traditionally in STEM, a convergent beam of electrons is focused onto the sample, and a 2D raster image is recorded. The intensity distribution created by the interactions of the electrons and the sample can be acquired in various ways including bright field (BF), dark field (DF) or high angle annular DF (HAADF), where a single value of electron counts is contributed to a single pixel. In 4D-STEM Ophus 2019 , on every pixel of a 2D STEM image, a CBED or diffraction pattern (DP) is acquired using a charge-coupled device (CCD) or pixelated camera – hence giving additional 2D angular diffraction information. Coupling the speed of modern cameras with hardware synchronized beam control yields staggering acquisition speeds – as 100k frames per seconds ( fps ) are being reported Chatterjee et al. 2021 . Rather than a specialized single technique, 4D-STEM is a family of different acquisition modes, where either a real or diffraction space image is acquired at every pixel. It has been successfully used in visualizing electric and magnetic fields Fang et al. 2019 ; Nguyen et al. 2016 , strain Allen et al. 2021 and orientation mapping Jeong et al. 2021 , structure determination Shukla et al. 2016 and ptychography Muller et al. 2019 . It is hence likely, that the near future roadmap within the field of STEM accelerates to combine and fuse multi-modal data Thersleff et al. 2020 ; Thersleff and Tai 2023 e.g. using 4D-STEM with electron energy loss spectroscopy (EELS) and/or X-ray energy dispersive spectroscopy (EDS); while simultaneously aspire towards multiple dimensions e.g. by applying electron tomography Weyland and Midgley 2004 and/or in-situ electron microscopy Zheng and Zhu 2017 . Figure 1: The preparation of needle-shaped sample using FIB processing: (a) The milling of the conic sample using circular patterns at relatively high ion currents ( 1-10\,\textrm{nA} ); (b) Lifting out the section from the main sample using the micromanipulator and mounting the cone on top of the TEM grid using carbon deposition; (c) Fine-milling of the sample with low ion currents ( 50-500\,\textrm{pA} ) until a needle with a dimeter less than )100\,\textrm{nm} )is reached. The St4DeM was written as a suite to collect and implement various 4D-STEM acquisition modes into one package, additionally incorporating energy filtering TEM (EFTEM), 3D EELS and EDS chemical mapping techniques. The software suite was written within the Digital Micrograph (DM) scripting environment Mitchell and Schaffer 2005 , which is a popular software platform installed in most electron microscope controlling computers worldwide. Here, the basic 4D-STEM acquisition mode, 4D-STEM tomography, 4D visualization, and analysis methods are introduced, with a focus on the proof of principle of the software rather than the detailed analysis of the samples. In addition, but not shown here, AutoEM particle sizing software AutoEM Uusimäki et al. 2019 was incorporated into St4DeM, allowing 4D-STEM and EELS/EDS spectrum imaging (SI) acquisition of unlimited number of nanoparticles with serial montage imaging as used in particle sizing methods. The basic 4D-STEM imaging of St4DeM has already been explored and published in Bello-Jurado et al. 2022 ; Willhammar et al. 2021 . Momentum resolved EELS was shown, as electron magnetic circular dichroism (EMCD) in Ali et al. 2023 . The software suite, the acquired original data and the analysis code used in this paper can be downloaded from https://github.com/AutoEM/St4DeM and https://zenodo.org/record/7529702#.Y8_YEHbMJP . II Materials and Methods The Fe 3 O 4 nanoparticles were synthesized by decomposition of Fe(acac) 3 in the presence of oleic acid (OA) and Na-oleate precursors, as reported in Ulusoy et al. 2024 . 6 mmol of Fe(acac) 3 was mixed with 12 mmol OA and 0.1 mmol of Na-oleate by adding 40 mL dibenzyl ether, 40 mL octadecene and 12 mL tetradecene solvents. The mixture was magnetically stirred and degassed at room temperature for 1h. Then, the slurry was heated up to reflux temperature ( \sim 290 °C) at a rate of 20 °C/min under Argon atmosphere and kept at this temperature for 30 min. After cooling to room temperature, the resultant product was washed 3-4 times with a mixture of toluene and ethanol (1:4) and centrifuged 6000 rpm for 5 min discarding the supernatant to remove residual organics. This step is repeated by sequential operations of dispersing in toluene, precipitation by adding ethanol and centrifuge until organic amount is less than 2 %. Fe 3 O 4 nanoparticles with cubic shape and edge length of l=73\pm 9\,\textrm{nm} were synthesized. The carbon nanotube powder and rare earth element (REE) nanoparticles (allanite, monazite and parisite) were dispersed in hexane and deposited onto TEM grid by drop on grid technique. A lab-fabricated TiNi shape memory alloy (SMA) for dental applications, was prepared using focused ion beam milling at the JEOL 4601F MultiBeam System. The sample was circularly ion-milled using the annular patterns (Figure 1) at 30\,\textrm{keV} ion energy and with the ion currents ranging from 10\,\textrm{nA} down to 50\,\textrm{pA} for coarse/fine thinning and polishing stages, respectively, until an electron-transparent pin is formed. The software was tested and developed using a Thermo Fischer 300\,\textrm{kV} Cs-corrected Themis and a 200\,\textrm{kV} JEOL JEM-2100F microscope (Stockholm and Trondheim), with DM versions 3 and 2 respectively. The successfully tested cameras in Themis were a local Gatan Quantum 965 ER and a remote Gatan Oneview, and on JEOL Gatan Ultrascan 1000, GIF Tridiem and Orius. The Oneview camera control software was located on an external PC, hence a boost library karlsson 2005 UDP server was created on the microscope PC controlling the beam scanning, and the Oneview image acquisition was synchronized as a client. The Oneview camera can operate at 300\,\textrm{fps} acquisition speed, however since a server/client connection was used to synchronize the acquisition and scanning, the speed was limited to 100\,\textrm{fps} . Figure 2: STEM HAADF images (a) and (b) acquired using a Thermo Fischer

Read the complete text