The Imaging Time-of-Propagation Detector at Belle II

H. Atmacan, M. Belhorn, Y. Guan, L. Li, B. Pal, S. Sandilya, A. J. Schwartz, B. Wang, S. Watanuki, M. Andrew, M. Barrett, M. Bessner, T. E. Browder, J. Bynes, J. Cercillieux, S. Dubey, O. Hartbrich, C. Ketter, B. Kirby, S. Kohani, D. Kotchetkov, L. Macchiarulo, B. Mac̆ek, K. Nishimura, H. Purwar, Z. · 2025

Read The Imaging Time-of-Propagation Detector at Belle II by H. Atmacan, M. Belhorn, Y. Guan, L. Li, B. Pal, S. Sandilya, A. J. Schwartz, B. Wang, S. Watanuki, M. Andrew, M. Barrett, M. Bessner, T. E. Browder, J. Bynes, J. Cercillieux, S. Dubey, O. Hartbrich, C. Ketter, B. Kirby, S. Kohani, D. Kotchetkov, L. Macchiarulo, B. Mac̆ek, K. Nishimura, H. Purwar, Z. (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-19090.txt.

Introduction

Hulya Atmacan and a large team of co-authors reported this detector paper in 2025. It describes the imaging Time-of-Propagation detector at Belle II, a particle experiment in Japan. The device tells apart pions, kaons, and protons by the Cherenkov light they shed while crossing polished quartz bars. The light bounces inside the bar to sensors at one end, while a mirror at the far end sends strays back.

Both the arrival times and hit spots of the light are logged. Together they fix the light's angle, which betrays the particle's kind for speeds up to a set range. The paper covers the build, the running, and the scores of the device. By its writing, the detector had logged nearly 600 inverse femtobarns of collision data. Such tagging is key to sorting the rare decays Belle II hunts.

Catalog record

CREATORH. Atmacan, M. Belhorn, Y. Guan, L. Li, B. Pal, S. Sandilya, A. J. Schwartz, B. Wang, S. Watanuki, M. Andrew, M. Barrett, M. Bessner, T. E. Browder, J. Bynes, J. Cercillieux, S. Dubey, O. Hartbrich, C. Ketter, B. Kirby, S. Kohani, D. Kotchetkov, L. Macchiarulo, B. Mac̆ek, K. Nishimura, H. Purwar, Z.
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE105 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-19090

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

The Imaging Time-of-Propagation Detector at Belle II H. Atmacan, M. Belhorn, Y. Guan, L. Li, B. Pal, S. Sandilya, A. J. Schwartz, B. Wang, S. Watanuki, M. Andrew, M. Barrett, M. Bessner, T. E. Browder, J. Bynes, J. Cercillieux, S. Dubey, O. Hartbrich, C. Ketter, B. Kirby, S. Kohani, D. Kotchetkov, L. Macchiarulo, B. Mac̆ek, K. Nishimura, H. Purwar, Z. Sang, V. Shebalin, S. Tripathi, G. Varner, K. Yoshihara, T. Kohriki, X. Wang, S. P. Maharana, V. S. Vismaya, G. Visser, A. Gaz, S. Lacaprara, R. Stroili, E. Torassa, R. Mussa, U. Tamponi, P. Križan, S. Korpar, T. Nanut, A. Novosel, M. Petric̆, L. Rizzuto, M. Staric̆, L. M. Cremaldi, D. A. Sanders, Y. Adachi, Y. Arita, D. Furumura, S. Hara, T. Hayakawa, S. Hirose, Y. Horii, T. Iijima, K. Inami, Y. Ito, Y. Kato, N. Kiribe, R. Koga, K. Kojima, A. Maeda, Y. Maeda, K. Maehara, R. Maeshima, K. Matsuoka, G. Muroyama, T. Nakano, R. Okubo, R. Okuto, R. Omori, S. Senga, K. Suzuki, H. Takeichi, N. Tsuzuki, T. Yonekura, R. Conrad, J. Fast, B. Fulsom, J. Strube, L. Wood, I. Danko, T. Gu, N. Herring, N. K. Nisar, S. Roffe, V. Savinov, E. Wang, V. Bhardwaj, A. Loos, M. Purohit, C. Rosenfeld Abstract We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + ​ e − e^{+}e^{-} collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c c . To date, the detector has been used to record and analyze almost 600 fb -1 of Belle II data. [orcid=0000-0003-2435-501X] [orcid=0000-0003-4489-7668] [orcid=0000-0002-5541-2278] [orcid=0000-0002-7366-1307] [orcid=0000-0003-0737-1528] [orcid=0000-0002-4199-4369] [type=editor, orcid=0000-0002-7310-1983] [orcid=0000-0001-6136-6952] [orcid=0000-0002-5241-6628] [orcid=0000-0002-2095-603X] [orcid=0000-0003-1776-0439] [orcid=0000-0001-7357-9007] [orcid=0000-0002-1345-0970] [orcid=0000-0001-7741-4381] [orcid=0000-0002-5161-9722] [orcid=0000-0003-3869-6552] [orcid=0000-0001-8818-8922] [orcid=0000-0002-3876-7069] [orcid=0000-0003-1012-0957] [orcid=0000-0002-0302-8151] [orcid=0000-0002-3656-2326] [orcid=0000-0002-1746-4683] [orcid=0000-0002-1606-5349] [orcid=0000-0003-2495-758X] [orcid=0000-0001-6754-3315] [orcid=0000-0002-0551-7696] [orcid=0000-0002-3453-142X] [orcid=0000-0003-2321-0599] [orcid=0000-0002-0294-9071] [orcid=0000-0001-6651-0706] [orcid=0000-0002-4967-7675] [orcid=0000-0003-0971-0968] [orcid=0000-0002-5728-9867] [orcid=0000-0002-7308-8950] [orcid=0000-0002-1331-2578] [orcid=0000-0001-6621-6646] [orcid=0000-0001-8751-5944] [orcid=0000-0001-5550-7827] [orcid=0000-0002-4902-966X] [orcid=0000-0002-4271-711X] [orcid=0000-0003-2765-7072] [orcid=0000-0001-6314-4288] [orcid=0000-0002-3638-0266] [orcid=0000-0003-1706-9365] [orcid=0009-0009-0912-0678] [orcid=0000-0003-1141-1908] [orcid=0000-0003-2258-701X] [orcid=0000-0002-5862-9739] [orcid=0000-0001-7470-9301] [orcid=0000-0002-5235-8181] [orcid=0000-0002-1470-6536] [orcid=0000-0001-9562-1253] [orcid=0000-0002-9184-2830] [orcid=0000-0001-6391-5118] [orcid=0000-0001-8857-8621] [orcid=0000-0002-8381-8689] [orcid=0000-0003-3857-1223] keywords time-of-propagation ,Cherenkov ,particle identification † † corresponding: Corresponding author: Physics Department, University of Cincinnati, P.O. Box 210011, Cincinnati, Ohio 45221 ([email protected]). † † now at Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA. † † now at Hunan Normal University, Changsha, China. † † now at Nevis Laboratory, Columbia University, New York, New York, USA. † † now at Nalu Scientific, Honolulu, Hawaii, USA. † † now at Paradromics, Austin, Texas, USA. † † deceased † † now at Fudan University, Shanghai, China. † † now at Thomas Jefferson National Accelerator Facility, Newport News, Virginia, USA. † † now at Brookhaven National Laboratory, Upton, New York, USA. † † now at Indian Institute of Science Education and Research, Mohali, Punjab, India. This paper is dedicated in memory of Gary Varner, who played a fundamental role in the design, fabrication, and operation of the electronics for the TOP detector. 1 Introduction The Belle II detector [ 1 ] is a large, multi-purpose particle detector that operates at the SuperKEKB e^{+}e^{-} collider [ 2 ] located at the KEK accelerator laboratory in Tsukuba, Japan. The experiment records e^{+}e^{-} collisions at center-of-mass energies at or near the \Upsilon(4S) resonance, and studies weak decays of B and D mesons and \tau leptons. The detector includes silicon pixels and strips to measure decay vertices, a large central tracking chamber in a magnetic field to reconstruct particle tracks and measure particle momenta, an electromagentic calorimeter to measure energies of electrons and photons, and an array of resistive plate chambers and scintillator modules to detect muons and neutral K^{0}_{L} mesons. Positioned radially between the central tracker and the calorimeter is a “time-of-propagation” (TOP) detector with imaging, which measures the propagation time and hit positions of Cherenkov photons in order to identify pions, kaons, protons, and deuterons. This paper describes the construction, operation, and performance of the TOP detector. The design of the imaging TOP is based on the principle of total internal reflection (TIR) of Cherenkov light [ 3 , 4 , 5 , 6 , 7 , 8 ] . This principle was employed by the DIRC detector [ 9 ] of the BABAR experiment [ 10 ] . Like BABAR ’s DIRC, the Belle II TOP uses optically polished bars of synthetic fused silica (quartz) as the radiator material. 1 1 1 The BABAR quartz bars were narrower – only 3.5 cm wide – to reduce the probability that two tracks in an event traverse the same bar. When charge tracks traverse these bars, they radiate Cherenkov photons that propagate via TIR to the ends. At one end is attached a mirror to reflect photons, such that all TIR photons ultimately arrive at the other end. At that end the photons refract out of the bar and onto an array of photomultiplier tubes (PMTs), where their hit positions and arrival times are recorded. Design work on the imaging TOP began in 2009, construction began in 2012, and installation was completed in the spring of 2016 [ 11 , 12 ] . Since that time, the detector has been operating continuously and has thus far recorded almost 600 fb -1 of e^{+}e^{-} collision data [ 13 , 14 , 15 ] . Its ability to discriminate among pions, kaons, and protons has been used in almost all Belle II physics analyses to date. This paper is organized as follows. In Section 2 we describe the optical components of the TOP, their testing, and assembly; in Section 3 we describe the light-tight enclosure within which the optical components reside, and the support structure; in Section 4 we describe the photomultiplier tubes used to record Cherenkov photons; in Section 5 we describe the readout electronics; in Section 6 we describe the gas system; in Section 7 we describe the procedures for calibrating the detector; in Section 8 we describe the reconstruction algorithm; in Section 9 we discuss the operation of the detector; and in Section 10 we discuss its performance. 2 Optical components A TOP optics module consists of two bars of length 125 cm, width 45 cm, and thickness 2.0 cm. The bars are glued together on their narrow faces, as shown in Fig. 1 (left). A reflective mirror with a spherical surface is mounted at one end, and a prism is mounted at the other end. Attached to this prism is an array of micro-channel-plate photomuliplier tubes (MCP-PMTs). The optical components are fabricated from Corning 7980 synthetic fused silica (quartz), which has high purity and minimal striae; together these components are referred to as an optics module. The optics module is sealed within a light-tight