Read Characterisation of Hamamatsu R11065-20 PMTs for use in the SABRE South NaI(Tl) Crystal Detectors by Y.Y. Zhong (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-17209.txt.
Introduction
Members of the SABRE South collaboration, Zhong among them, characterize light sensors for a dark matter detector in a 2025 paper. The experiment uses sodium iodide crystals to check a long-standing claimed signal. Twin detectors run in Italy and Australia.
The sensors must work near the noise floor, where fake signals lurk. The team developed pre-calibration steps for gain, dark rate, and timing. They also built a way to calibrate in place without a light source. A machine learning classifier trained on single-sensor responses helped sort background from signal-like pulses. Simulation tools generate realistic sensor data from optical models. The work readies the southern detector for installation. Careful sensor knowledge guards the search's credibility.
Catalog record
| CREATOR | Y.Y. Zhong |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 63 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-17209
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Characterisation of Hamamatsu R11065-20 PMTs for use in the SABRE South NaI(Tl) Crystal Detectors Y.Y. Zhong Abstract The SABRE Experiment is a direct detection dark matter experiment using a target composed of multiple NaI(Tl) crystals. The experiment aims to be an independent check of the DAMA/LIBRA results with a detector in the Northern (Laboratori Nazionali Del Gran Sasso, LNGS) and Southern (Stawell Underground Physics Laboratory, SUPL) hemispheres. The SABRE South photomultiplier tubes (PMTs) will be used near the low energy noise threshold and require a detailed calibration of their performance and contributions to the background in the NaI(Tl) dark matter search, prior to installation. We present the development of the pre-calibration procedures for the R11065-20 Hamamatsu PMTs. These PMTs are directly coupled to the NaI(Tl) crystals within the SABRE South experiment. In this paper we present methodologies to characterise the gain, dark rate, and timing properties of the PMTs. We develop a method for in-situ calibration without a light injection source. Additionally we explore the application of machine learning techniques using a Boosted Decision Tree (BDT) trained on the response of single PMTs to understand the information available for background rejection. Finally, we briefly present the simulation tool used to generate digitised PMT data from optical Monte Carlo simulations. 1 Introduction The SABRE (Sodium iodide with Active Background REjection) [ 1 , 2 , 3 , 4 ] South experiment is a NaI(Tl) dark matter (DM) direct detection experiment designed to provide a model-independent test of the long-standing modulating signal observed by the DAMA/LIBRA experiment [ 5 ] , with sensitivity to confirm or reject this result. DAMA/LIBRA observes a modulation in the recoil rate in NaI(Tl) in the 1-6 keV {}_{\text{ee}} electron equivalent energy region, corresponding to about 5.5 – 45 photoelectrons (PE) [ 5 ] with DAMA/LIBRA’s light yield (LY). The observation is consistent with an annual modulation due to DM interactions. This result is the only evidence for direct detection of DM, with current NaI(Tl) experiments being in tension with the DAMA/LIBRA observations [ 6 , 7 ] . Other direct detection experiments have produced more stringent constraints on the spin-independent cross section for WIMP-like dark matter models, making use of different target materials and detector designs [ 8 , 9 ] . Of those that have searched for annual modulations [ 10 , 11 ] , none have found a signal consistent with the DAMA/LIBRA observation. SABRE South will be located at the Stawell Underground Physics Laboratory (SUPL) with 1025 m of flat rock overburden providing 2870 m of water equivalent shielding [ 3 ] . The SABRE South experiment has, as DM target, a set of 7 \times 7 kg ultra-high purity NaI(Tl) crystals [ 12 , 3 ] , each directly coupled to two 76 mm Hamamatsu Photonics (HPK) R11065-20 PMTs encased in enclosures made with high purity oxygen-free copper. The enclosures are flushed with nitrogen to prevent contamination from potential outgassing of Teflon components, other internal sources of 210 Pb, and to protect the NaI(Tl) crystals, which are highly soluble in water. The enclosure will be submerged within an active veto system with 11.6 m 3 of linear-alkylbenzyene liquid scintillator [ 13 ] instrumented with at least 18 \times 204 mm HPK R5912 PMTs 1 1 1 Additional PMTs from the decommissioned Daya Bay experiment have been acquired and are being considered for installation. . The vessel is encased in a passive shield comprised of steel and polyethylene layers which shields from external radiation and neutrons. A muon veto system comprised of eight EJ200 scintillators (40 \times 300 \times 5 cm) each coupled to two HPK R13089 PMTs covering a total area of 9.6 m 2 is placed on top of the passive shielding. The detector will operate at a temperature of 22 \degree C. Currently running NaI(Tl) experiments have observed rate excesses above the expected background models at energies in the DAMA region of interest (RoI) of 1 – 6 keV {}_{\text{ee}} [ 6 , 14 ] . These excesses are most prominent in the 1 – 3 keV {}_{\text{ee}} region and become small above 3 keV {}_{\text{ee}} . A potential origin of this background is noise introduced by the PMTs and the data acquisition readout system [ 15 ] . This may also bias the annual modulation search, as the residual rate for some searches is determined by subtracting a time-dependent background model [ 16 , 17 ] . To be sensitive to a signal in the DAMA/LIBRA RoI (1 – 6 keV {}_{\text{ee}} ), PMTs are required to operate stably with sensitivity to single photons throughout the lifetime of the experiment, without making a significant contribution to the experimental background. The HPK R11065 PMTs were selected for the SABRE South experiment due to their low dark rate, high quantum efficiency (QE) [ 18 ] (the typical NaI(Tl) LY, for a PMT with 30 \% QE is 12 PE keV -1 ) and high efficiency around the emission spectrum for NaI(Tl) shown in Fig. 1 . Figure 1 : The typical spectral response for the R11065 and R11410 PMTs [ 19 ] . The shaded region shows where the emission spectrum of NaI(Tl) is above 50 \% of the peak emission amplitude. The vertical line indicates the emission peak at 415 nm. [ 18 ] The HPK R11065 PMT was developed together with the HPK R11410 as both PMTs are designed for use in low background experiments. The HPK R11410 was optimised for very ultra-violet (VUV) emissions in liquid xenon and operated by dark matter detectors such as XENONnT and LUX-ZEPLIN (LZ) [ 20 , 8 ] . The HPK R11065 was developed for operation with liquid argon using a wavelength shifter to 420 nm and is used in the DarkSide experiment [ 19 , 11 ] . Each SABRE PMT was selected by the manufacturer to have a QE >30\% . Accurate characterisation of the HPK R11065-20 PMT’s gain, dark rate, timing, and after-pulsing properties are crucial to help understand systematic errors in event selection and energy scale, the degradation in performance of the detectors over time, and to inform methods for long term in-situ calibration. Pre-calibration allows for control of the experimental conditions by making use of reference detectors (silicon photomultipliers (SiPMs) and scintillator panels) as well as a controlled source (pico second pulsed laser). Several pre-calibration measurements (such as transit-time) cannot be absolutely calibrated in-situ (or will be dominated by other signals), and others such as gain can be calibrated directly with a light source rather than via scintillation. In contrast to the PMTs of the SABRE South veto system, the crystal system will not have any in-situ optical calibration system. In this paper, we describe the methods and procedures that will be applied in the pre-calibration of the SABRE South R11065 PMTs. This is demonstrated on two of the PMTs with serial numbers BC0174 and BC0175 (delivered in 2020 from HPK). All PMTs purchased by SABRE have been tested by HPK to have QEs between 30.06 \% and 33.25 \% at 420 nm. The pre-calibration measurements are used in SABRE South Monte Carlo detector simulations to understand the PMT related background contribution in the RoI, and to