Read Orientation and mobility test in virtual reality, a tool for quantitative assessment of functional vision: dataset and evaluation in healthy subjects by Yujie Huang *,†, Audrey Crozet *, Toinon Vigier, Alexandre Bruckert, Patrick Le Callet, Pierre Lebranchu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-13735.txt.

Introduction

Six authors build a virtual reality test of functional vision in this 2025 paper. Orientation and mobility tests measure how well people use sight to move through space, a truer gauge of daily vision than eye charts, but real courses are hard to standardize.

Their seated virtual test varies lighting and course layout while players navigate a path and clear marked obstacles. Forty-two normally sighted people took the test, and the team logged completion time, missed objects, and hesitation before the first step. Behavior around missed objects carried extra signal. The paper releases the first dataset of its kind and argues the protocol can sharpen vision assessment.

Catalog record

CREATORYujie Huang *,†, Audrey Crozet *, Toinon Vigier, Alexandre Bruckert, Patrick Le Callet, Pierre Lebranchu
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE58 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-13735

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Orientation and mobility test in virtual reality, a tool for quantitative assessment of functional vision: dataset and evaluation in healthy subjects Yujie Huang *,†, Audrey Crozet *, Toinon Vigier, Alexandre Bruckert, Patrick Le Callet, Pierre Lebranchu Abstract Purpose: The purpose of this study was to develop and evaluate a novel virtual reality seated orientation and mobility (VR-S-O&M) test protocol designed to assess functional vision. This study aims to provide a dataset of healthy subjects using this protocol and preliminary analyses. Methods: We introduced a VR-based O&M test protocol featuring a novel seated displacement method, diverse lighting conditions, and varying course configurations within a virtual environment. Normally sighted participants (N=42) completed the test, which required them to navigate a path and destroy identified obstacles. We assessed basic performance metrics, including time duration, number of missed objects, and time before the first step, under different environmental conditions to verify ecological validity. Additionally, we analyzed participants’ behaviors regarding missed objects, demonstrating the potential of integrating behavioral and interactive data for a more precise functional vision assessment. Results: Our analyses revealed that performance metrics, including time duration and time before the first step, were affected by lighting levels, with a threshold effect observed at higher levels. Although no significant differences were found in time duration and orientation time across different course configurations, the number of missed objects varied significantly, indicating differences in difficulty levels. In addition, behavioral analyses identified different several potential error categories (e.g., lack of visual analysis of the environment, difficulty in detection, misuse of the setup) and the potential most challenging object features (position and color) to infer vision problems. Conclusions: Our VR-S-O&M test protocol demonstrated feasibility and validity on healthy subjects, showing the impact of illumination, revealing the exist of different difficulty levels in our environment configurations. This study highlighted the need for further investigation into the causes of errors and the effects of different configurations on performance. Translational Relevance: Our VR-S-O&M test protocol, along with the first O&M behavior dataset, presents significant opportunities for developing more refined performance metrics for assessing functional vision and enhancing the quality of life. † † footnotetext: * These authors contributed equally to this work. † † footnotetext: † Corresponding author: Yujie Huang ( [email protected] ) 1 Introduction Functional vision is a key concept in visual impairment and refers to a person’s ability to perform vision-related tasks [ 1 ] . A decline in functional vision can significantly affect the Quality of Life (QoL) across all age groups [ 2 ] . In contrast to visual functions such as visual acuity, color vision, contrast vision, ocular motility and visual field which are assessed using standardized, validated and quantitative instruments, the evaluation of functional vision is far more complex and less commonly performed. Currently, there are two primary methods for measuring functional vision [ 3 , 4 ] : quality of life questionnaires [ 5 , 6 , 7 , 8 , 9 , 10 ] and physical orientation and mobility (O&M) tests [ 11 , 12 , 13 , 14 , 15 ] . The former lacks objectivity, while the latter presents challenges in distribution, reproducibility, and is often bulky, time-consuming and costly. One of the most advanced O&M tests for assessing functional vision is the Multi Luminance Mobility Test (MLMT) [ 11 ] . This test was specifically developed to demonstrate the functional benefit of treatment voretigene neparvovec, the first reimbursed gene therapy in ophthalmology, for patients with hereditary retinal dystrophy caused by the bi-allelic mutation of RPE65. The MLMT assesses functional vision by incorporating standardized variations in light conditions. Reproducibility was a key consideration in the development of MLMT, ensuring that different test centres could conduct the tests under identical conditions. To minimize the learning effect, multiple courses with obstacles were designed. Each run was recorded and reviewed by two independent, trained observers. The test demonstrated clinical benefits in functional vision by showing that patients had shorter course completion times and fewer collisions with obstacles after treatment. However, despite its thoughtful design, the MLMT has several limitations, including the need for a dedicated room with calibrated lighting, the time-consuming nature (need for the assessor to change the layout of the course frequently), the cost and the constraints imposed by its patent. Many of these drawbacks can be overcome by using virtual reality (VR). Virtual reality is a rapidly advancing field that is already being used in ophthalmology for low vision rehabilitation [ 16 , 17 , 18 ] . Building on the MLMT, virtual reality orientation and mobility tests have been developed to assess functional vision in patients with inherited retinal dystrophies (IRD) [ 19 , 20 ] , to simulate the vision with a retinal prosthesis and optimize its placement on the retina [ 21 , 22 ] , as well as to evaluate the severity of visual impairment in glaucomatous patients [ 23 ] . The primary limitation of these virtual reality O&M tests is that they require the subject to move physically, which necessitates a large space, poses potential safety risks, induces fear, and is not suitable for patients with mobility impairments. We believe that virtual reality can address the primary limitations of the aforementioned tests, particularly by allowing patients to remain seated in a swivel chair during the assessment. Visually impaired patients often have difficulty walking, which may be related to a fear of falling or bumping into obstacles [ 24 ] . By opting for a seated position, we can reduce the variability in walking patterns across different patients and enable those with motor impairments (such as multiple sclerosis, diabetes, or stroke) to undergo mobility testing. With the development of innovative therapies and medical devices for visually impaired individuals, there is an increasing need for a rigorous, quantitative, and reproducible assessment of functional vision. The key advantages of virtual reality include the ability to create controlled virtual environments that closely mimic real-world conditions, the reproducibility of testing environments, the automated recording of attentional and behavioral data, and the potential reduction in costs. Assessing visual functions alone is not always sufficient to demonstrate clinical therapeutic benefits in ophthalmology. This is partly because individual visual functions do not fully capture the complexity of functional vision in everyday life, and partly because existing tools for assessing different visual functions may not be feasible for patients with visual impairments. In addition to its utility in clinical research, this tool could also be valuable for studying the natural history of blinding conditions. In this study, we introduce our Virtual Reality Seated Orientation and Mobility dataset (VR-S-O&M) involving healthy subjects, and provide analyses of its validation. Specifically, we describe the development of our O&M test, the details of the displacement mode, the various course configurations and lighting levels, and the evaluation conducted with visually healthy subjects. To our knowledge, this is the first dataset for O&M testing of functional vision that includes rich behavioral information and detailed scenario configurations, offering researchers a promising opportunity to better understand individual behaviors. 2 Methods 2.1 Materials The virtual reality environments were developed using Unity, coded in C# (Unity editor version 2020.3.35f1, SteamVR version 1.24.6, SRanipal Runtime version 1.3.6.8). The Head-Mounted Display (HMD) used was the HTC