Reactive power flow optimization in AC drive systems
Sanjay Chandrasekaran, Catalin Arghir, Pieder Jörg, Florian Dörfler, Silvia Mastellone · 2025
Read Reactive power flow optimization in AC drive systems by Sanjay Chandrasekaran, Catalin Arghir, Pieder Jörg, Florian Dörfler, Silvia Mastellone (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-10360.txt.
Introduction
Sanjay Chandrasekaran and co-authors tune spare power flow in motor drives to dodge hard caps in a 2025 paper. Drives face caps on both input swing and output flow, which can force stops. In one band of spare power, those two caps trade off, and that slack can be spent on safety.
Two plans spend it. One bends the spare power goal toward safety through a smooth switch, and one sets it live by loop feedback. Both trade a bit of goal truth for far more uptime, and rich models show the gains hold for plant use.
Catalog record
| CREATOR | Sanjay Chandrasekaran, Catalin Arghir, Pieder Jörg, Florian Dörfler, Silvia Mastellone |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 38 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-10360
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Reactive power flow optimization in AC drive systems Sanjay Chandrasekaran, Catalin Arghir, Pieder Jörg, Florian Dörfler, Silvia Mastellone Abstract This paper explores a limit avoidance approach in the case of modulation (input) and current (output) constraints with the aim of enhancing system availability of AC drives. Drawing from the observation that, in a certain range of reactive power, there exists a trade-off between current and modulation magnitude, we exploit this freedom and define a constrained optimization problem. We propose two approaches: one in the form of an activation-function, and another that uses online feedback optimization to set the reactive power dynamically. Both methods compromise reactive power tracking accuracy for increased system robustness. Through a high-fidelity simulation, we compare the benefits of the two methods, highlighting their effectiveness in industrial applications. I INTRODUCTION Medium voltage (MV) drives are widely used in industrial applications, including heat pumps, compressors or wind turbines, where they enable efficient and precise control of large electrical machines at variable speed [ 1 , 2 ] . These drives often employ voltage-source converters (VSCs) to regulate power flow and maintain stability and flexibility of operation. However, during some transient events such as overload or grid disturbances, the drive system can experience overcurrent and overmodulation, leading to degraded performance, and in extreme cases, system shutdown. In applications such as oil and gas, the unplanned interruption of the process results in high financial loss. Thus, system availability requirements are sometimes prioritized over performance and efficiency. Reactive power in drive systems is typically regulated to zero [ 3 ] in order to minimize losses. However, in megawatt-scale applications, MV drives with active front-ends can significantly influence grid behavior, making reactive power management a crucial factor [ 4 ] . The design of AC drive systems generally involves a trade-off between efficiency and robustness to grid conditions, allowing some margin for reactive power needed for Static Synchronous Compensator (STATCOM) features [ 5 ] . In applications such as wind energy, VSCs actively regulate the point of common coupling (PCC) voltage or may participate in grid-forming control [ 6 ] . In other cases, they provide ancillary services by allowing the reactive power set point to be determined by the grid operator or by implementing a droop between reactive power and voltage. However, the VSC has a limited range of supplying reactive power. Its constraints arise in the static case, due to design limitations, and the dynamic case, as a function of instantaneous active power, DC-link voltage, and grid conditions [ 7 , 8 ] . We propose a constraint-aware dynamic adaptation of the reactive power set-point that accounts for external demands while respecting system constraints. In this study, we investigate two competing methods, an activation-function approach and an optimization-based technique leveraging Online Feedback Optimization (OFO). Both methods operate as outer-loops to existing controllers with anti-windup limiters, preventing them from entering the saturated mode of operation whenever possible. By integrating these strategies, we enhance both transient and steady-state performance when compared to state-of-the-art current limiters [ 9 , 10 , 11 ] . In the context of power systems, various types of strategies for limiting converter current are employed [ 12 , 13 , 14 , 15 ] . We aim to leverage the relationship between anti-windup and the projected gradient descent mechanism found in OFO [ 16 ] . In a similar scenario [ 17 ] , OFO is used to steer fast nonlinear dynamics. In [ 18 ] , it is used to optimize reactive power flow in a distribution grid by prescribing the inverter set-points while enforcing voltage constraints. In our work, we take a deeper look into the single-inverter case and enforce constraints with the aim of internal stability. The rest of the paper is organized as follows: Section II formulates the problem, describing the system model, control assumptions, and constraints. Section III goes over the control design, while Section IV presents the OFO convergence guarantees. Section V provides simulation results that illustrate performance improvements achieved by the proposed methods. Finally, Section VI concludes the paper with a discussion of key findings. II Problem statement We consider a power conversion system consisting of a grid-side converter, a DC-link capacitor, a motor-side converter, an electrical machine, and a driveline shaft attached to a motoring or generating load. The main role of the grid-side converter, is to deliver active power by regulating the DC-link voltage, and thus allow the motor-side converter to supply the load under a wide range of external conditions. Our main goal is to design an outer loop for the reactive-power component of the grid current reference to avoid overmodulation or overcurrent limits and preserve DC-link regulation. Our proposal is to exploit the trade-off between converter current and modulation constraints and override the external reactive power set-point. The problem setup is developed under the following assumptions . Assumption 1 The drive system is modeled based on the following set of assumptions: i. Changes in set-points, load torque, and the grid voltage have limited bandwidth; ii. The inner loop of the motor-side converter is assumed to have sufficiently fast bandwidth such that, together with the motor dynamics, it can be abstracted out of the overall model by assuming that the motor torque is perfectly tracking its set-point. Assumption 1 (i) provides a limit on the variation of external disturbances. Assumption 1 (ii) implies that energy is preserved from the drive shaft to the DC-link. The second assumption is motivated by the fact that most modern MV motor controllers adopt a form of direct Model predictive control (MPC), or Direct torque control (DTC) [ 19 , 20 ] , to track the torque set point with high bandwidth. II-A Drive system model In the rest of this section, we explain a typical industrial drive and its core control system. We propose to use the following energy-preserving, average-switch model of a back-to-back drive system: \displaystyle M\dot{{w}} \displaystyle=-D{w}+{\tau}_{m}{}-\tau_{l} (1a) \displaystyle C_{dc}\dot{v}_{dc} \displaystyle=-G_{dc}v_{dc}-\tfrac{{{w}}}{v_{dc}}{\tau}_{m}{}+m_{g}{}^{\top}i_{g} (1b) \displaystyle L_{g}\dot{i}_{g} \displaystyle=-Z_{g}i_{g}+v_{g}-m_{g}{}v_{dc}\,, (1c) where M,D are the moment of inertia and viscous damping of the driveshaft, w its angular velocity, {\tau}_{m} is the motor air-gap torque (control input), \tau_{l} is the driveshaft load torque (unmeasured disturbance), v_{dc} is the DC-link voltage, C_{dc} its capacitance and G_{dc} its parallel conductance. Furthermore, m_{g}\in\mathbb{R}^{2} is the grid-side converter dq -modulation vector (control input), L_{g},R_{g}>0 phase inductance and resistance, respectively, i_{g}\in\mathbb{R}^{2} is the grid current (towards the converter) and v_{g}\in\mathbb{R}^{2} is the voltage in dq -coordinates (measured disturbance). Finally, the grid impedance (in dq -coordinates) is given by Z_{g}=\begin{bmatrix}R_{g}&-\omega_{0}L_{g}\\ \omega_{0}L_{g}&R_{g}\end{bmatrix} . We use the well established notions of instantaneous power [ 21 ] and the power-invariant dq -frame transformation as x_{abc}\mapsto x_{dq0}=T_{\theta_{g}}T_{\alpha\beta\gamma}x_{abc} such that T_{\alpha\beta\gamma}^{-1}=T_{\alpha\beta\gamma}^{\top} and T_{\theta_{g}}^{-1}=T_{\theta_{g}}^{\top} , and assume that the grid voltage angle \theta_{g} is measured. Moreover, by virtue of the third-harmonic injection, the maximum modulation amplitude in dq -coordinates becomes \tfrac{1}{\sqrt{2}} . II-B Drive system objectives We consider the following tracking objectives, \displaystyle{w} \displaystyle\rightarrow{w}^{\mathrm{ref}} (2) \displaystyle v_{dc} \displaystyle\rightarrow v_{dc}^{\mathrm{ref}} (3) \displaystyle Q_{g}=v_{g}^{\top}Ji_{g} \displaystyle\rightarrow Q_{g}^{\star}\,\text{ , where }\,J=\begin{bmatrix}0&-1\\ 1&0\end{bmatrix}\,\,, (4) while rejecting external disturbance \tau_{l},v_{g} . Moreover, |{w}^{\mathrm{ref}}|\leq w_{\mathrm{max}} and |Q_{g}^{\star}|\leq Q_{\mathrm{max}} are slowly changing external set-points. The system is subject to fast changing loads |\tau_{l}|\leq\tau_{\mathrm{max}} and occasional dips in