Static Magnetic Properties of Cryogel ® and Pyrogel ® at Low Temperatures and in High Magnetic Fields

Caeli L. Benyacko, Garrett T. Hauser, Raven J. Rawson, Alan J. Sherman, Quinton L. Wiebe, Krittin Poottafai, Daniel R. Talham, Mark W. Meisel · 2025

Read Static Magnetic Properties of Cryogel ® and Pyrogel ® at Low Temperatures and in High Magnetic Fields by Caeli L. Benyacko, Garrett T. Hauser, Raven J. Rawson, Alan J. Sherman, Quinton L. Wiebe, Krittin Poottafai, Daniel R. Talham, Mark W. Meisel (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-09962.txt.

Introduction

Caeli Benyacko and seven co-authors report 2025 measurements of how two silica aerogel blankets answer magnets when cold, given in short form. The pair, sold as Cryogel and Pyrogel, are feather-light insulation used in harsh settings. The team measured their steady magnetic traits from near two degrees above absolute zero up to four hundred, in fields up to seventy thousand gauss. They pair the data with a model of the response, so engineers can know the traits before using the blankets in magnet-heavy gear.

Catalog record

CREATORCaeli L. Benyacko, Garrett T. Hauser, Raven J. Rawson, Alan J. Sherman, Quinton L. Wiebe, Krittin Poottafai, Daniel R. Talham, Mark W. Meisel
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE15 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-09962

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Static Magnetic Properties of Cryogel ® and Pyrogel ® at Low Temperatures and in High Magnetic Fields Caeli L. Benyacko, Garrett T. Hauser, Raven J. Rawson, Alan J. Sherman, Quinton L. Wiebe, Krittin Poottafai, Daniel R. Talham, Mark W. Meisel Abstract The static magnetic properties of the silica-based aergoels of Cryogel ® and Pyrogel ® , manufactured by Aspen Aerogels ® , were measured over a range of temperatures (2 K ≤ \leq T ≤ \leq 400 K) and in magnetic fields up to 70 kG. These data and a model of the responses are reported so these properties are familiar to others who may benefit from knowing them before the materials are employed in potential applications. keywords aerogels, magnetic properties, low temperatures, high magnetic fields Version of August 10, 2026 at 1 Motivation Using the phrase “low temperature aerogels” during a search for thermal isolation materials, a paper by a CERN-based research team appeared Ilardi et al. 2020 , which reported studies of the thermal conductivity of Cryogel ® , but the magnetic properties were not found in any database. While learning more about the low-temperature insulation trademarked as Cryogel ® by Aspen Aerogels Aspen Aerogels 2025 , the high-temperature counterpart Pyrogel ® was identified as potential insulation for a materials-processing in high magnetic-fields station that was being constructed Flynn et al. 2022 ; Flynn et al. 2025 . Consequently, a sample-pack was purchased, and undergraduate research students were trained to acquire, analyze, and report the magnetic data Sherman et al. 2022 ; Wiebe et al. 2022 ; Benyacko et al. 2024 . In an attempt to be useful to others who may be interested in the low temperature and high magnetic field results, this brief report summarizes the findings and discusses the outcomes with a focus on Cryogel ® , while the magnetic properties of Pyrogel ® are also presented. After overviewing the samples and methods employed, the low-field temperature dependences and isothermal responses of the magnetism are presented, anlayzed, and summarized. 2 Samples and Methods The sample-pack received contained nominally (40 cm) 2 sheets of five materials, specifically the samples (and their thicknesses) were: Cryogel ® X201 (5 mm and 10 mm) Aspen Aerogels 2015a , Cryogel ® Z (5 mm and 10 mm) Aspen Aerogels 2015b , and Pyrogel ® XTE (10 mm) Aspen Aerogels 2017 , whose compositions are provided in Table 1 . Table 1: Compositions of Cryogel ® and Pyrogel ® reported in this work. 0 0 footnotetext: NOTE: The exact percentages (concentrations) of the compositions were withheld as trade secrets. Composition (%) Cryogel ® Cryogel ® Pryogel ® Constituent Formula X201 Aspen Aerogels 2015a Z Aspen Aerogels 2015b XTE Aspen Aerogels 2017 Synthetic Amorphous Silca SiO 2 40-50 25-40 30-40 Methylsilyated Silica C 6 H 19 NSi 2 10-20 10-20 10-20 Polyethylene Terephthalate C 10 H 8 O 4 10-20 10-20 Fibrous Glass (textile grade) 1 1 1 The Chemical Abstracts Service Registry Number was not given, so our assumption is listed here. SiO 2 10-20 10-20 40-50 Magnesium Hydroxide Mg(OH) 2 \;\,0-\;\,5 \;\,0-\;\,5 Aluminum Foil 2 2 2 Samples were taken in regions away from this foil and its immediate region. Al \;\,0-\;\,5 Iron Oxide (Fe(III) oxide) Fe 2 O 3 1-10 Aluminum Trihydrate AlH 3 O 3 1-\;\,5 Samples, with a typical mass, m , in the range 20-40 mg, were extracted from the sheets and gently pressed directly into a \sim\, 7 mm long section of the straw sample holders, which provided a uniform background for the detection scheme used by the commercial magnetometer, Quantum Design MPMS XL, capable of providing a range of temperature (2~\mathrm{K}\leq T\leq 400~\mathrm{K}) and magnetic field (-70~\mathrm{kG}\leq B\leq 70~\mathrm{kG}) conditions. When studying Cryogel ® Z, the aerogel-like samples were taken from a region away from the aluminum foil and its immediate surrounding location. The studies of the temperature dependence of the low-field magnetization were performed in zero-field cooling (ZFC) and field-cooling (FC) modes and were then followed by isothermal (usually at T=5 K) magnetization measurements while increasing ( B=0\rightarrow 70 kG) and then decreasing ( B=70~\mathrm{kG}\rightarrow-10 kG) the field to check for hysteresis. For this report, the data are expressed in cgs units where a magnetic moment, \mu , is 1 emu = 1 erg G -1 Blundell 2001 , so the following notation is employed for the mass magnetization M=\mu/m (emu/g) and the mass susceptibility \chi=M/B (emu g -1 G -1 ). For inductively-coupled plasma optical-emission spectroscopy (ICP-OES), a Pyrogel ® XTE or Cryogel ® X201 sample with a mass of 10 mg was dissolved in 20 mL of 1 M KOH solution and left overnight to allow the silica to be digested so the metal ions could dissociate from the fiber. The solution was then adjusted to an acidic pH using 1 M HNO 3 to dissolve any metal oxide and subsequently diluted with deionized water to make the final sample solution. The ICP-OES study employed a VARIAN VISTA RL simultaneous spectrometer (Agilent Technologies, Santa Clara, California, USA) using standard addition methods. 3 Magnetic Data and Discussion In low applied magnetic fields, the initial conjecture was the high-temperature magnetic signal would be dominated by the diamagnetism of the SiO 2 matrix Jr. 2024 , and the low-temperature response might show evidence of some trace amounts of free-spin S=1/2 impurities Sarachik et al. 1985 ; Matsuoka et al. 2012 for Cryogel ® , whereas signatures reminiscent of the well-studied magnetism of Fe(III) 2 O 3 Zboril et al. 2002 were anticipated for Pyrogel ® . Although some of these signatures appeared in the data, Fig. 1 , other features were not anticipated. Figure 1: The temperature dependent magnetic susceptibilities of Pyrogel ® XTE and the 5 mm and 10 mm thick sheets of Cryogel ® X210 and Cryogel ® Z are shown. (a) The mass susceptibility of Pyrogel ® XTE measured in B=0.1\,\mathrm{kG} exhibits a strong Curie-like tail at low temperatures, differences between FC and ZFC data below a blocking temperature near 130 K, and a sharp shoulder at the Morin transition of 260 K, which are assignable to the known presence of Fe 2 O 3 , see Table 1 . (b) The low magnetic field ( B=1\,\mathrm{kG} ) mass susceptibility data for all four samples of Cryogel ® are almost degenerate on a linear temperature scale, so the inset shows the resuts on a logarithmic scale for T<100\,\mathrm{K} . In most instances, the ZFC and FC data are the same within measuring uncertainty, and the strength of the Curie-like response at low temperature is striking. More specifically for Pyrogel ® XTE, Fig. 1 (a), the differences between ZFC and FC traces below a blocking temperature of \approx 130 K and a strong Curie-like tail were not surprising Maldonado-Camargo et al. 2017 , while the appearance of the magnetic ‘ ‘fingerprints” of a Morin transition at 260 K Morin 1950 ; Suber et al. 1998 ; Kubániová et al. 2019 were not anticipated. Since Fe(III) oxide is listed as an ingredient of Pyrogel ® , see Table 1 , the observed magnetic behavior is consistent with the presence of a broad distribution of Fe 2 O 3 nanoparticles with diameters in the

Read the complete text