The PUMA offline ion source beamline Journal: Nuclear Instruments and Methods in Physics Research Section A
Moritz Schlaich, Paul Fischer, Paul Florian Giesel, Clara Klink, Alexandre Obertelli, Lutz Schweikhard, Frank Wienholtz · 2025
Read The PUMA offline ion source beamline Journal: Nuclear Instruments and Methods in Physics Research Section A by Moritz Schlaich, Paul Fischer, Paul Florian Giesel, Clara Klink, Alexandre Obertelli, Lutz Schweikhard, Frank Wienholtz (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-08870.txt.
Introduction
Moritz Schlaich and co-authors published an instrumentation paper in 2025 on an offline ion source beamline built for an antimatter experiment at CERN. The experiment studies the outer matter of stable and radioactive nuclei with low-energy antiprotons. No single site makes both ingredients, so antiprotons must travel between facilities. Tests with stable isotopes need a stand-in ion source at the antiproton site.
The beamline delivers pure, cooled, bunched ion beams above a stated rate per bunch. It also keeps the vacuum at the handover point extremely low. The paper describes the setup and proves its performance using stable krypton isotopes as the example.
Catalog record
| CREATOR | Moritz Schlaich, Paul Fischer, Paul Florian Giesel, Clara Klink, Alexandre Obertelli, Lutz Schweikhard, Frank Wienholtz |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 38 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-08870
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The PUMA offline ion source beamline Journal: Nuclear Instruments and Methods in Physics Research Section A Moritz Schlaich, Paul Fischer, Paul Florian Giesel, Clara Klink, Alexandre Obertelli, Lutz Schweikhard, Frank Wienholtz Abstract The antiProton Unstable Matter Annihilation experiment (PUMA) at CERN aims to study the nucleonic composition in the matter density tail of stable and radioactive nuclei using low-energy antiprotons. Since there is no facility in which both low-energy antiprotons and radioactive nuclei can be produced, the experimental realization with exotic nuclei requires the transportation of the antiprotons from the Extra Low ENergy Antiproton (ELENA) facility to the nearby located Isotope mass Separator On-Line DEvice (ISOLDE). For tests and first applications of the proposed experimental technique to stable isotopes at ELENA, a dedicated offline ion source beamline was developed that will provide isotopically pure, cooled and bunched ion beams with intensities of more than 10 4 10^{4} ions per bunch while maintaining a vacuum of better than 5 × 10 − 10 mbar 5\text{\times}{10}^{-10}\text{\,}\mathrm{mbar} at the handover point. This offline ion source beamline is characterized and its capabilities are demonstrated using the example of stable krypton isotopes. 1 Introduction Figure 1: Top view of the PUMA offline ion source beamline CAD representation. A multi-species ion beam is generated and chopped in the ion source before it is mass-separated in the MR-ToF MS and cooled and bunched in the RFQcb. Subsequently, the purified ion bunches are guided through the transfer beamline towards the PUMA Penning trap. The four sections (indicated by dashed lines) can be separated by gate valves. Four ion detectors (MagneTOF 1-4) and a Faraday cup (FC) allow independent optimization of the ion-optical components in each section including lens and steering electrodes (ion optics 1-5) and pulsed drift tubes (PDT 1-3) for energy modifications of the ion beam. Adjustable iris apertures (iris 1-5) are used to restrict the conductance at five locations. The unique and exclusive sensitivity of low-energy antiprotons interacting with the tail of the nuclear density distribution [ 1 ] allows the study of phenomena that occur in the periphery of atomic nuclei such as the formation of neutron skins in neutron-rich nuclei or the occurrence of halo nuclei [ 2 ] close to the proton and neutron drip lines, respectively. While the understanding of neutron skins can help to constrain the nuclear equation of state [ 3 , 4 , 5 ] , thus connecting nuclei with large-scale nucleonic systems like, e.g., neutron stars [ 6 , 7 ] , the latter can be used to investigate nuclear few-body systems [ 8 ] . To this end, the PUMA experiment intends to measure the neutron-to-proton annihilation ratio on the surface of stable and radioactive nuclei via antiproton-nucleus annihilations [ 9 ] . The experimental realization of the proposed technique requires the formation of antiprotonic atoms [ 10 , 11 ] with the nuclei of interest, which is achieved by trapping both the respective ions and the antiprotons together in a nested Penning trap [ 12 , 13 ] . Following the antiproton capture in a high-energy orbital of the atom, the antiproton decays into lower energy states until it reaches the nuclear surface. As a result, the antiproton annihilates with either a proton or neutron located in the tail of the nuclear density distribution. The study of the annihilation products provides the neutron-to-proton annihilation ratio as an observable for the characterization of the isospin asymmetry in the density tail of atomic nuclei. The PUMA experiment will be conducted at the European Organization for Nuclear Research (CERN) where the low-energy antiprotons will be obtained from the Extra Low ENergy Antiproton (ELENA) facility [ 14 , 15 ] at the Antimatter Factory while the radioactive ions will be provided by the Isotope mass Separator On-Line DEvice (ISOLDE) [ 16 ] . The PUMA Penning trap is integrated in a transportable frame so that antiprotons can be accumulated at ELENA and brought to ISOLDE, where the experiment with radioactive nuclei is performed. For an application of the proposed technique independent of the antiproton transport, the measurements at ISOLDE are complemented by an experimental program on stable nuclei at ELENA. Consequently, the PUMA experiment requires a versatile offline ion source at ELENA that is capable of producing a broad range of ion species where each is provided with isotopic purity to allow isotope-selective measurements. As the rate of annihilation with the isotopes of interest must exceed the rate of annihilations with residual gas particles, which should be less than 1\text{\,}\mathrm{Hz} inside the Penning trap [ 9 ] , the injection of the ions with an intensity of more than 10^{4} ions per bunch is required. Furthermore, the ion source must be operated at a pressure below 5\text{\times}{10}^{-10}\text{\,}\mathrm{mbar} , measured at the junction to the antiproton beamline, to meet the strict vacuum requirements. This value has been determined by simulations for the condition that the pressure in front of the PUMA trap stays below {10}^{-11}\text{\,}\mathrm{mbar} , which would ensure antiproton storage times of more than 100 days. [ 9 ] . 2 Experimental setup The PUMA OffLine Ion Source (POLIS) beamline consists of four main sections. An overview of the experimental setup is shown in Fig. 1 . In the first section, an electron-impact ionization source (SPECS Surface Nano Analysis GmbH, IQE 12/38) produces ions from gaseous target materials. During typical operation, a continuous ion beam is extracted from the ionization region at 3\text{\,}\mathrm{keV} , which is chopped by a beam deflector (see Sec. 2.3 ). It is followed by a quadrupole ion bender that will enable the addition of further ion sources perpendicular to the beamline. It is foreseen to equip the section with a surface ionization source and a laser ablation ion source at a later stage. Figure 2: Time-of-flight spectra of chopped ions extracted from the ion source using the residual gas in the ionization chamber (top) and krypton gas (bottom) as target material. Guiding the ions through the MR-ToF MS without being captured, the signal is measured using MagneTOF 2. See text for the ion species corresponding to the indicated mass numbers and further details. Downstream of the ion bender, ion optical elements guide the ion bunches into a multi-reflection time-of-flight mass spectrometer (MR-ToF MS) [ 17 ] , where they are captured using the in-trap lift technique [ 18 ] and separated according to their mass-over-charge ratio. In-trap deflector electrodes synchronized with the revolution frequency of the ions of interest deflect unwanted ion species, ensuring the transmission of the ions of interest only [ 19 ] . Once ejected from the MR-ToF MS, again using the in-trap lift technique [ 20 ] , the purified ions traverse another set of ion optical components, where they are decelerated to about 300\text{\,}\mathrm{eV} using a pulsed drift tube (PDT) and injected into a radio-frequency quadrupole cooler-buncher (RFQcb). Repeating this sequence, multiple purified ion packets can thus be accumulated in the RFQcb until the targeted ion intensity of > 10^{4} ions per bunch is reached. This has the advantage that the initial intensity of the continuous ion beam can be reduced, which has a positive effect on the lifetime of the ion source. Efficient ion accumulation requires the introduction of