Read Development and Performance Analysis of Glass-Based Gas-Tight RPCs for Muography Applications by S. Ikram, S. Basnet, E. Cortina Gil, P. Demin, R.M.I.D. Gamage, A. Giammanco, R. Karnam, V. K. S. Kashyap, V. Kumar, B. Mohanty, M. Moussawi, A. Samalan, M. Tytgat (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-08146.txt.
Introduction
Ikram and co-authors develop a portable detector that images with muons, the heavy cousins of electrons raining from the sky. Their device is a glass resistive plate chamber sealed gas-tight, designed to be robust, cheap, and easy to run far from a lab. Different builds are tested over several months.
The team tracks how the glass surface resistance drifts with time and how detection efficiency responds to voltage and trigger settings. A small trial imaging lead blocks by muon absorption shows the concept works. The authors aim the design at muography jobs where logistics are tight, from scanning structures to peering inside sealed targets.
Catalog record
| CREATOR | S. Ikram, S. Basnet, E. Cortina Gil, P. Demin, R.M.I.D. Gamage, A. Giammanco, R. Karnam, V. K. S. Kashyap, V. Kumar, B. Mohanty, M. Moussawi, A. Samalan, M. Tytgat |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-08146
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Development and Performance Analysis of Glass-Based Gas-Tight RPCs for Muography Applications Preprint: AIP/123-QED S. Ikram, S. Basnet, E. Cortina Gil, P. Demin, R.M.I.D. Gamage, A. Giammanco, R. Karnam, V. K. S. Kashyap, V. Kumar, B. Mohanty, M. Moussawi, A. Samalan, M. Tytgat Abstract To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood and widely used, our work focuses on developing a gas-tight variant specifically tailored for a broad range of muography applications, with key design goals including portability, robustness, autonomy, versatility, safety, and cost-effectiveness. Our RPC detectors are designed with various configurations, each featuring unique characteristics and performance attributes. We investigate the temporal evolution of the surface resistivity of glass electrodes, as well as the detector efficiency at varying voltages and thresholds, over a span of several months. These RPCs have been utilized in a small-scale feasibility study on muon absorption using lead blocks. I Introduction While imaging techniques employing radiation sources such as X-rays and neutrons have demonstrated success in many contexts, their feasibility diminishes when the objects of interest are too large or not transportable. An alternative approach, gaining popularity in recent years, is the use of naturally occurring cosmic-ray muons for imaging large-scale structures through absorption or scattering—a technique known as muography [ Bonechi et al. 2020 ]. The goal of our project is to develop a portable muon telescope customized for applications where the deployment of detectors is constrained by limited space availability, remoteness of location or other logistical issues. Potential use cases include speleology, archaeometry, mineral exploration, and the non-invasive imaging of cultural heritage, such as monumental statues and architectural decorations. In this context, our goal includes portability, robustness, safety and autonomy. Portability imposes strong limitations in both weight and size [ Gamage et al. 2022 ]. To ensure reliable performance across varying ambient conditions, robustness is essential, while safety remains a critical factor, especially in confined spaces. To meet these challenges, we are developing compact and autonomous muon detector prototypes optimized for imaging relatively small volumes of interest in complex and logistically demanding environments. Our detectors are based on Resistive Plate Chambers (RPC), chosen for their convenient trade-off between performance on one side and cost and complexity of construction on the other side [ Giammanco et al. 2022 ], operated in sealed mode to minimize risks associated with the presence of gas sources in confined volumes [ Basnet et al. 2020 ]. This article presents an evaluation of the detector’s performance and stability, and is organized as follows: Section II describes the setup used in the performance measurements reported in this paper, while Section III presents stability and performance studies. Section IV showcases the findings from a muon absorption measurement in a lead block, an important step to assess the potential of our current prototypes for muography applications. Lastly, Section V summarizes this study and outlines future directions for the project. II RPC Design and Laboratory Setup This paper reports on three prototypes, indicated as A, B and C, that were built and characterized at the various partner institutes of this project. Our detectors are built in different configurations, which enables us to evaluate the impact of subtle variations in design choices. These detectors operate using a CMS-RPC gas mixture composed of of 95.2% Freon, 0.3% SF6, and 4.5% isobutane at atmospheric pressure. For prototype A, chambers are equipped with a charge-sensitive front-end board borrowed from the Muon-RPC system of the CMS experiment [ Abbrescia et al. 2000 ]. The board comprises a charge-sensitive Application-Specific Integrated Circuit (ASIC) combined with a Field-Programmable Gate Array (FPGA). For prototype B,the data-acquisition was based on the CAEN DT5550W [ CAEN 2024 ] complete DAQ board comprising a PETIROC ASIC and FPGA. The ASIC is responsible for processing charge signals, while the FPGA handles data processing and event triggering. The high-voltage (HV) supply ensures stable operation of the detector components. A detailed description of the CMS readout board and the complete DAQ system is provided in Refs. [ Samalan et al. 2024 ; Gamage et al. 2022 ; Kumar et al. 2024 ]. Prototype C was mainly tested using a VME-based data-acquisition system, where a CAEN V792 QDC equipped with two A992 for 50 \Omega impedance matching was used to determine the RPC avalanche charges and chamber efficiency. The prototypes have been tested under various voltage and charge threshold configurations. II.1 Prototype A The RPCs are constructed using 20\times 20~{cm}^{2} glass plates with a thickness of 1.1~mm . These plates have an active area of 16\times 16~{cm}^{2} , coated with a resistive material consisting of paints with a surface resistivity ranging from 0.5 to 1.0 M\Omega/\square . A uniform gas gap of 1~mm is maintained between the plates. As shown in Fig. 1 , the plates along with a readout board are placed inside an aluminum gas enclosure containing a standard gas mixture. The enclosure contains a gas volume of 1.9 L , with internal dimensions of approximately 32.5\times 24.0\times 2.45~{cm}^{3} . The chamber is flushed 4 – 5 times at a gas flow rate of 0.2 L/min to ensure the thorough removal of residual air. After flushing, the chamber is sealed by closing the inlet and outlet gas valves. The current readout configuration features 16 strips, each measuring 18 cm in length, 0.9 cm in width with a pitch of 1 cm [ Kumar et al. 2025 ]. Figure 1 : Schematic of glass based RPC placed inside a gas enclosure [ Kumar et al. 2025 ]. II.2 Prototype B Prototype B is a muon telescope built in a modular form with four layers as shown in FIG. 2 . Each layer holds a glass RPC as a tracking detector element that is housed in an airtight casing constructed with acrylic material (Polymethyl methacrylate, PMMA). The RPC is sandwiched between two orthogonally placed Printed Circuit Board (PCB) based strip readout panels, to provide X and Y position of the muon hit as can be seen in Figure 3 . The RPCs are built using 20\times 20\times 0.3 cm^{3} size glass electrodes. These are 0.2 cm wide single gas gaps and standalone such that the gas flows only between the electrodes. The readout board has sixteen copper strips with 1 cm pitch on a 0.14 cm thick FR4 sheet. Further, the four modules are stacked inside an aluminium frame mounted on an alt-azimuthal platform which allows the telescope to rotate in steps of 5 \degree with respect to both azimuth and zenith angles. This feature allows the telescope to point in the direction of the volume of target under investigation. Figure 2 : Conceptual design of the muon telescope that is under construction. (Prototype B). Figure 3 : Conceptual design of the RPC module for prototype B. II.3 Prototype C Following the validation of initial single-gap chambers, a more advanced double-gap glass RPC chamber, prototype C, was constructed. It features a compact design with minimal gas volume and improved gas tightness plus 2D readout. The chamber contains two 1 mm gas gaps, each made of 1.1 mm thick float glass electrodes with a 28\times 28