Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

G. Carosi, C. Cisneros, N. Du, S. Durham, N. Robertson, C. Goodman, M. Guzzetti, C. Hanretty, K. Enzian, L. J Rosenberg, G. Rybka, J. Sinnis, D. Zhang, John Clarke, I. Siddiqi, A. S. Chou, M. Hollister, A. Sonnenschein, S. Knirck, T. J. Caligiure, J. R. Gleason, A. T. Hipp, P. Sikivie, M. E. Solano, · 2025

Read Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX by G. Carosi, C. Cisneros, N. Du, S. Durham, N. Robertson, C. Goodman, M. Guzzetti, C. Hanretty, K. Enzian, L. J Rosenberg, G. Rybka, J. Sinnis, D. Zhang, John Clarke, I. Siddiqi, A. S. Chou, M. Hollister, A. Sonnenschein, S. Knirck, T. J. Caligiure, J. R. Gleason, A. T. Hipp, P. Sikivie, M. E. Solano, (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-07279.txt.

Introduction

Carosi and the ADMX team report a search for axion dark matter in a narrow radio band, in a paper from twenty twenty-five. Axions are light particles that could make up all dark matter. They could also solve a long-standing puzzle in particle physics. The ADMX tool uses a strong magnet to turn axions into photons.

A tuned cavity boosts the signal at the target frequency. A deep cooler and a near-perfect amplifier cut noise to very low levels. In the latest run, the team scanned from one point one to one point three gigahertz. They reached the sensitivity needed to test a leading axion model. No axion signal is claimed in the report. The paper details the run and the setup.

Catalog record

CREATORG. Carosi, C. Cisneros, N. Du, S. Durham, N. Robertson, C. Goodman, M. Guzzetti, C. Hanretty, K. Enzian, L. J Rosenberg, G. Rybka, J. Sinnis, D. Zhang, John Clarke, I. Siddiqi, A. S. Chou, M. Hollister, A. Sonnenschein, S. Knirck, T. J. Caligiure, J. R. Gleason, A. T. Hipp, P. Sikivie, M. E. Solano,
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE26 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-07279

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX G. Carosi, C. Cisneros, N. Du, S. Durham, N. Robertson, C. Goodman, M. Guzzetti, C. Hanretty, K. Enzian, L. J Rosenberg, G. Rybka, J. Sinnis, D. Zhang, John Clarke, I. Siddiqi, A. S. Chou, M. Hollister, A. Sonnenschein, S. Knirck, T. J. Caligiure, J. R. Gleason, A. T. Hipp, P. Sikivie, M. E. Solano, N. S. Sullivan, D. B. Tanner, R. Khatiwada, L. D. Duffy, C. Boutan, T. Braine, E. Lentz, N. S. Oblath, M. S. Taubman, E. J. Daw, C. Mostyn, M. G. Perry, C. Bartram, J. Laurel, A. Yi, T. A. Dyson, S. Ruppert, M. O. Withers, C. L. Kuo, B. T. McAllister, J. H. Buckley, C. Gaikwad, J. Hoffman, K. Murch, M. Goryachev, E. Hartman, A. Quiskamp, M. E. Tobar, ADMX Collaboration Abstract Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10-1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov (KSVZ) sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup. This Letter reports the results of a search by the Axion Dark Matter eXperiment (ADMX) covering the frequency range from 1.10-1.31 GHz (4.54-5.41 \mathrm{\SIUnitSymbolMicro} ), over which we achieved sensitivity to plausible models for the quantum chromodynamic (QCD) axion. Our new results describe a previously unexplored region of parameter space for axion dark matter. The axion is a hypothetical particle that emerges from the Peccei-Quinn (PQ) solution to the strong CP problem [ 1 , 2 , 3 ] . In addition to solving the strong CP problem, axions may be produced abundantly in the early universe through the misalignment mechanism, allowing them to account for all the dark matter in the universe [ 4 , 5 , 6 , 7 ] . In the case where PQ symmetry was broken before cosmological inflation, axions over a broad mass range can elegantly account for all the dark matter in the universe [ 8 , 9 ] . If PQ was broken after inflation, theory suggests that the axion mass lies in the \mathcal{O}(1\text{--}100)~\mu eV range [ 10 , 11 , 12 , 13 , 14 , 15 , 8 , 16 , 17 , 9 , 18 , 19 , 20 ] . The coupling of axions to photons is model dependent, but two benchmark models are commonly used: the Kim-Shifman-Vainshtein-Zakharov (KSVZ) axion [ 21 , 22 ] and the more feebly coupled Dine-Fischler-Srednicki-Zhitnitsky (DFSZ) axion [ 23 , 24 ] . ADMX searches for dark matter axions using an axion haloscope [ 25 , 26 , 27 ] , which uses the Primakoff effect resonantly to convert axions to photons in a strong magnetic field. The experimental configuration in this run of the ADMX haloscope was similar to that reported in detail in Ref. [ 28 ] and updated in Ref [ 29 ] . In previous runs, ADMX excluded both benchmark models for QCD axion dark matter over several hundred MHz [ 29 , 30 , 31 , 32 , 33 ] . For the operations reported in this letter, the resonator system was outfitted with a different tuning rod, an improved noise calibration load, and improved cryogenic heat sinking, all with the aim of improving thermal and RF performance in the target frequency range. The resonator used by ADMX in this experimental run is a right cylindrical copper plated stainless steel cavity (with length 101.4 cm and diameter 41.9 cm) tuned by a single 20.3 cm copper tuning rod placed inside the 139-liter cavity, as shown in Fig. 1 . The cavity was centered inside a solenoidal magnet. The magnet is energized by a constant current source delivering 225 A and is stable to within 1 mA. The magnetic field along the solenoid’s longitudinal axis decreases from 7.8 T at the central midplane to 5.3 T at the top and bottom ends of the cavity. An off-center axle enabled rotation of the tuning rod from the wall of the cavity to near the center of the cavity, changing the resonant frequency. Across the frequency range of the experiment, the cavity unloaded quality factor was about 90,000. Two dipole antennas were inserted into the cavity for signal injection and readout. The first was a “weakly coupled” antenna inserted into the bottom of the cavity. It is fixed to be weakly coupled to the cavity. The second was a “strongly coupled” antenna, inserted into the top of the cavity. The coupling of the antenna, \beta , was controlled by a linear gearbox which adjusted the insertion depth of the antenna. The ability to vary the coupling ensured that the antenna was kept in an overcoupled state to optimize the scanning for axions across the full tuning range of the run [ 34 ] . Both the tuning rod and antenna gearboxes are activated by room-temperature stepper motors via a long G10 fiberglass shaft to enable automated adjustment over the course of the entire run. When tuned to the frequency of the photon ( \nu_{a}=\frac{m_{a}c^{2}}{h} ) produced from the Primakoff effect, a persistent and coherent signal would develop within the cavity. The axion signal would follow an assumed Maxwell-Boltzmann distribution associated with the kinetic-energy distribution of dark matter within the local Milky Way halo [ 35 ] .The expected power coupled out of the cavity of an axion haloscope is [ 25 ] \displaystyle P_{\mathrm{axion}}=1.8\cdot 10^{-23}~\text{W}\left(\frac{V}{106~\ell}\right)\left(\frac{B}{7.6~\text{T}}\right)^{2}\left(\frac{C}{0.4}\right) \displaystyle\left(\frac{g_{\gamma}}{0.36}\right)^{2}\left(\frac{\rho_{a}}{0.45~\text{GeV/cc}}\right)\left(\frac{\nu_{a}}{800~\text{MHz}}\right)\left(\frac{Q_{L}}{45,000}\right) \displaystyle\left(\frac{\beta}{1+\beta}\right)\left(\frac{1}{1+(2\delta\nu_{a}/\Delta\nu_{c})^{2}}\right), (1) where V is the volume of empty space in the cavity, B is the magnitude of the external magnetic field, C is the cavity form factor (the overlap between the cavity resonant mode and the magnetic field), g_{\gamma} is the model-dependent numerical constant ( -0.97 the KSVZ model and 0.36 for the DFSZ model) which determines the axion-photon coupling, \rho_{a} is the expected dark matter density in the cavity, Q_{L} is the loaded quality factor of the cavity, which is related to the unloaded quality factor by the equation Q_{0}=Q_{L}(1+\beta) , \beta is the coupling coefficient of the antenna to the cavity mode, \delta\nu_{a} is the difference between the cavity resonance and axion signal frequency, and \Delta\nu_{c}=\frac{\nu_{a}}{Q_{L}} is the cavity linewidth. Here, the equation of the power has been normalized to reflect typical experimental parameters observed in ADMX. For axion haloscopes, the axion coupling to photons is related to the model-dependent constant by the equation g_{a\gamma\gamma}=\frac{\alpha g_{\gamma}}{\pi f_{a}} (2) where \alpha is the fine structure constant and f_{a} is the axion decay constant. Figure 1: A: The electric field map of the TM 010 mode simulated by COMSOL Multiphysics [ 36 ] where the direction is marked by the red arrows and the field magnitude by the color

Read the complete text