Read High efficiency quantification of 90 Sr contamination in cow milk after a nuclear accident Journal: Applied Radiation and Isotopes by Q. Rogliardo, A. Kanellakopoulos, H. Corcelle, M. Fedel, M. Zsely-Schaffter, G. Triscone, S. Pallada (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-07123.txt.

Introduction

Rogliardo and co-authors (2025) present a high-efficiency protocol for measuring strontium-90 contamination in cow's milk after a nuclear accident. The isotope is dangerous because it mimics calcium and settles in bones and teeth. Their method chains freeze-drying, high-temperature burning, ion exchange separation, and liquid scintillation counting.

On reference milk carrying a known activity, the protocol recovered essentially all of the strontium, about 100 percent, beating two established methods that recovered only about two thirds. Its detection limit under the best conditions was low, at 0.33 becquerels per liter. Checks against certified laboratories confirmed the readings, including the expected doubling of signal as the daughter isotope grew in over two weeks. The authors position the protocol as a sensitive, easy-to-run tool for emergency response and routine monitoring, and suggest testing it on other foods.

Catalog record

CREATORQ. Rogliardo, A. Kanellakopoulos, H. Corcelle, M. Fedel, M. Zsely-Schaffter, G. Triscone, S. Pallada
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE24 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-07123

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

High efficiency quantification of 90 Sr contamination in cow milk after a nuclear accident Journal: Applied Radiation and Isotopes Q. Rogliardo, A. Kanellakopoulos, H. Corcelle, M. Fedel, M. Zsely-Schaffter, G. Triscone, S. Pallada Abstract Monitoring 90 Sr contamination in milk following a nuclear accident is critical due to its radiotoxicity and calcium-mimicking behaviour, leading to accumulation in bones and teeth. This study presents a high-efficiency protocol for quantifying 90 Sr in cow milk by integrating freeze-drying, high-temperature calcination, ion exchange chromatography and liquid scintillation spectroscopy (LSC). The method was validated using reference milk samples with 0.45 Bq/mL of 90 Sr, achieving a chemical yield of 100 ± \pm 2%, ensuring near-complete recovery and accurate quantification. The minimum detectable activity (MDA) was estimated at 0.33 Bq/L under optimal conditions, demonstrating the protocol’s sensitivity for low-level detection. A comparative analysis with existing methods centrifugation-based approaches and Dowex resin techniques revealed that our protocol outperforms in both strontium recovery and organic matter elimination. Alternative methods showed lower recovery rates (68 ± \pm 2% for Guérin’s method, 65 ± \pm 6% for Dowex resin) and suffered from procedural drawbacks, such as incomplete organic matter removal. Applying this methodology to compare samples from certified laboratories confirmed its robustness, with liquid scintillation spectroscopy radioactivity values doubling after 14 days, consistent with secular equilibrium between 90 Sr and 90 Y. While the protocol is optimized for milk, future research should explore its applicability to other food matrices. The high yield, reliability, and ease of implementation position this method as an effective tool for nuclear emergency response and routine radiological monitoring. 1 Introduction In recent years, growing concerns over nuclear safety have intensified due to potential reactor accidents, unauthorized releases in the environment, and geopolitical conflicts involving nuclear weapons. In response, multiple European countries, alongside national and international agencies, have been developing environmental monitoring protocols for nuclear emergencies [ 1 , 2 ] . Many of these protocols prioritize food safety, with milk being a key focus due to its widespread consumption and its critical role in children’s nutrition. Radiocontaminated milk containing 90 Sr presents significant challenges due to its potential to propagate contamination through the food chain [ 3 ] . 90 Sr, a key radioisotope released during nuclear accidents, is a high-energy \beta - emitter with calcium-mimicking chemical and biological properties. This similarity raises major health concerns, as 90 Sr can be incorporated into teeth and bones, leading to long-term radiotoxic effects. This work presents a safe, efficient and user-friendly protocol for quantifying 90 Sr radioactivity in milk, following three key steps: elimination of organic matter, strontium separation and measurement of the extracted radioactivity. The protocol involves freeze-drying, followed by calcination at 700°C to remove organic content. Strontium is selectively separated using ion exchange chromatography and the extracted radioactivity is measured via liquid scintillation spectroscopy, with mass spectroscopy employed for yield quantification (see Fig. 1 ). Finally, the protocol’s accuracy and reliability are validated through comparisons with established methodologies from the literature. Figure 1: Flow chart of the developed protocol. 2 Materials and Methods 2.1 Reagents and Apparatus All the reagents used in this study (HCl, TCA, NaOH, Na 2 CO 3 , H 2 O 2 , HNO 3 , C 2 H 2 O 4 ) as well as the natural Sr tracer (ROTI ® Star, 1000 mg/L) used for yield measurements, were purchased from Carl Roth AG. Sr Resin ® chromatography columns (2 mL) were obtained from Eichrom Technologies Inc, while the 90 Sr standard solution (5 mL, 1.85 MBq at 01.02.2022) was sourced from Eckert & Ziegler Nuclitec GmbH. UHT milk (3.5 \% fat) was used for this study. Experimental setups included an Alpha 1-2 LDplus freeze dryer (Martin Christ GmbH) and a muffle furnace (Solo Switzerland) for calcination. Liquid scintillation measurements were performed using a TriCarb 2900TR spectrometer with Ultima Gold AB scintillation liquid (PerkinElmer). Chemical yields were determined via an Agilent 7700X ICP Mass Spectrometer. 2.2 Freeze drying Freeze-drying or else lyophilization, or else, is the initial step of the developed protocol, designed to convert liquid milk into dry powder and prevent issues associated with liquid milk calcination. The freeze-dryer is equipped with a three-tiered support, allowing three large-diameter Pyrex crystallizers to be placed under a glass dome during the process. The wide surface area minimizes sample thickness, thereby reducing drying time. Prior to freeze-drying, the samples are pre-frozen in a freezer overnight (approximately 18 h). The drying progress can be monitored by checking for liquid residues or ice at the bottom of the crystallizer. Upon completion, the milk forms a dry, easily detachable block, yielding approximately 12 g of powdered milk from 100 mL of liquid milk. The percentage of evaporated matter over time for a 100 mL crystallizer is illustrated in the Fig. 2 . Figure 2: Evaporated matter as a function of time. After 20h of freeze-drying, milk evaporation reaches a plateau at approximately 87 \% . Incomplete evaporation results in the formation of a fragile dried milk block that adheres to the container walls and becomes volatile during the calcination process. Extensive testing was performed to maximize the evaporated matter by optimizing the freeze-drying parameters, specifically pre-freezing and drying temperatures, while maintaining a consistent sample volume (100 mL per crystallizer over 24 hours). Results indicated that sample position significantly affects drying efficiency, with the sample closest to the condenser (see sample 3 in Table 1 ) exhibiting lower evaporation rates due to inadequate heat transfer during sublimation. The impact of pre-freezing and freeze-drying temperatures on the evaporated matter of the milk samples was found to be negligible, except for the sample positioned closest to the condenser. Based on these findings, the optimal configuration was determined to be pre-freezing at -20°C and freeze-drying at -40°C, ensuring efficient water removal while preserving the integrity of the powdered milk for subsequent processing steps. Evaporated matter (%) Pre-freezing -40°C -40°C -20°C -20°C Freeze drying -40°C -50°C -40°C -30°C Sample 1 87.29% 86.85% 87.33% 87.27% Sample 2 86.58% 84.76% 87.10% 87.17% Sample 3 83.98% 81.63% 86.29% 83.64% Table 1: Percentage of evaporated matter as a function of pre-freezing and freeze-drying temperatures. Maximum evaporation is observed for pre-freezing at -20°C and freeze-drying at -40°C. Sample closer to the condenser exhibits lower evaporation rates due to inadequate heat transfer during sublimation. 2.3 Calcination The powdered milk was transferred into a porcelain beaker and heated in a muffle furnace overnight (approximately 18 hours). Initially, calcination was performed at 550°C. However, organic matter removal was incomplete, yielding grayish ash (see Fig. 3 ). The colour of the ash serves as a reliable indicator of residual organic materials, with bright white signifying complete organic matter removal. Furthermore, calcined ash obtained at 550°C clogged the resin column or significantly reduced the flow rate. To address this issue, the calcination temperature was increased to 700°C. At this higher temperature, the resulting ash was white, indicating near-complete removal of organic matter. This optimization minimized interference during ion-exchange chromatography and ensured optimal separation efficiency. Furthermore, the flow rate during column separation aligned with the manufacturer’s specifications (0.6–0.8 mL/min), confirming the effectiveness of this temperature for reproducibility and yield. For 12 gr of powdered milk (equivalent to 100 mL of liquid

Read the complete text