New concept to measure the Poiseuille coefficient of rarefied gas flow driven by a large pressure drop

Felix Sharipov a, Irina Graur b · 2025

Read New concept to measure the Poiseuille coefficient of rarefied gas flow driven by a large pressure drop by Felix Sharipov a, Irina Graur b (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-06082.txt.

Introduction

Sharipov and Graur set a new way to gauge thin gas flow marks by vast drops. The mark, the Poiseuille mark, ties mass flow to press slope in a tube. It is key for craft that use void webs in their build. Stock counts solve a bent Boltzmann form for small drops. Small drops mean small flow, which makes lab reads faint. Faint reads force the mark out with more flaw in counts.

Their way pulls the mark from a vast-drop flow read. Vast drops lift flow a lot, which trims lab flaw in reads. That lift is the core gain of the new way in the text. Gear built on it should gauge the mark with more truth. The way is pitched to lab hands who build such gear.

Catalog record

CREATORFelix Sharipov a, Irina Graur b
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE14 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-06082

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

New concept to measure the Poiseuille coefficient of rarefied gas flow driven by a large pressure drop Felix Sharipov a, Irina Graur b Abstract The Poiseuille coefficient, which relates the mass flow rate through a long capillary to the local pressure gradient, is an important characteristic in designing various technological processes that include vacuum systems as part. This quantity is usually calculated by solving numerically the linearized Boltzmann equation assuming a small pressure gradient and, therefore, the mass flow rate is small too. As a result, to extract accurately this coefficient from experimental measurements, the mass flow rate must remain small. The present paper proposes a novel approach to extract the Poiseuille coefficient from a measurement of mass flow rate driven by a large pressure drop. Under these conditions, the flow rate increases significantly and, hence, the experimental error is reduced. The proposed method will help experimentalists in designing measurement devices to determine the Poiseuille coefficient with a higher accuracy. Keywords Rarefied gas, Poiseuille flow, rarefaction parameter, mass flow rate. I Introduction Over the past decades, research in rarefied gas dynamics has advanced significantly, driven by the growing demand of vacuum technology, aerospace research, miniaturization of technological processes, etc. Most progress has been made in theoretical approaches, including the development of new numerical methods for solving of kinetic equations CerB1 ; Sha02B , improvements in the direct simulation Monte Carlo technique Bir02 , and implementation of ab initio calculations Sha145 ; Dod01 . However, experimental data on several aspects of rarefied gas dynamics remain scarce, and their experimental uncertainty is relatively high. Therefore, further improvement of experimental methods is essential to obtain more reliable data. The Poiseuille coefficient, which relates the mass flow rate through a long capillary to the local pressure gradient, is widely used to model various processes in vacuum systems. For certain simple capillary cross-sections, such as cylindrical Cer16 ; Loy20 ; Sha45 , rectangular Loy20 ; Sha32 , elliptical Sha67 , and annular Bas02 ; Bre04 tubes, this coefficient has been calculated across all flow regimes, namely: free-molecular, transitional, and viscous. All these results have been obtained from the linearized Boltzmann equation or its kinetic models CerB1 ; Sha02B , which assume a low pressure gradient and consequently, a low mass flow rate. Despite this assumption, the Poiseuille coefficient is commonly used to calculate the mass flow rate through a long capillary driven by a high pressure drop Sha15 . Additionally, gas flows through a capillary with a variable cross-section can also be efficiently calculated via the Poiseuille coefficient Sha57 ; Gra11 . In many vacuum systems, the flow regime is viscous at the capillary inlet and free-molecular at the outlet, see e.g. Refs. Sha72 ; Sha112 . A direct solution of such a scenario requires significant computational effort. However, knowledge of the Poiseuille coefficient enables the calculation of both flow rate and pressure distribution along the capillary with modest computer resources. This is achieved using a general approach to transient flows in rarefied gases, as proposed in Ref. Sha103 , which is based on the Poiseuille coefficient. Besides capillary shape, the Poiseuille coefficient is influenced by several other factors, including the rarefaction parameter (inverse Knudsen number), gas species, chemical composition in case of gaseous mixture, and accommodation coefficients that characterize gas-surface interaction, etc. As a result, theoretical predictions of the Poiseuille coefficient are not always directly applicable to practical situations. Moreover, accommodation coefficients are often unknown and their determination through Molecular Dynamics simulations is complex Spi01 and frequently deviates from experimental assesses. Therefore, obtaining the Poiseuille coefficient experimentally is essential. Such experimental results could help validate theoretical models and extract accommodation coefficients for specific gas-surface interactions. The mass flow rate is usually measured via the pressure variation in the inlet volume connected to a capillary. The experimental data reported by Porodnov et al. Aki01 ; Por02 ; Sue02 are based on the assumption that the initial pressure difference between the capillary ends is small and decreases exponentially over time. In this case, the resulting flow rate is small leading to a large experimental error. When the initial pressure drop is large, the authors of Ref. Por04 did not extract the Poiseuille coefficient, but instead reported the ratio of the flow rate at an arbitrary Knudsen number to its value in the free-molecular regime. Similarly, the authors of Refs. Ewa01 ; Ewa02 ; Nac01 ; Per04 ; Roj02 considered a large initial pressure drop and reported the dimensional mass flow rate without extracting the Poiseuille coefficient. Some studies extract the Poiseuille coefficient from experiments with a large initial pressure drop, using the average pressure gradient and rarefaction parameter based on the average pressure, see e.g. Refs. Had09 ; Sil03 ; Pit01 ; Var01 . However, this approximation introduces an error, that can be significant in the case of wide rectangular channel Sha32 and elliptical tube Sha67 . In fact, the Knudsen minimum for these geometrical configurations is deep that hinders the use of average pressure to extract the Poiseuille coefficient. The present work proposes a new method to extract the Poiseuille coefficient from measurements of pressure decay in a reservoir caused by gas flow through a capillary driven by large pressure drop. II Formulation of the problem The Poiseuille coefficient G_{\mbox{\scriptsize P}} relates the mass flow rate through a long capillary to the local pressure gradient as Sha02B \dot{M}=-G_{\mbox{\scriptsize P}}\frac{Aa}{v_{m}}\frac{\,\mbox{d}p}{\,\mbox{d}x}, (1) where A is the cross-section area of the capillary, a is its characteristic transversal size, v_{m}=\sqrt{2R_{g}T/{\cal M}} is the most probable molecular speed, R_{g}=8.314 J/(K mol) is the universal gas constant, T is the gas temperature, {\cal M} is the molar weight of the gas, p is the gas pressure, and x is the longitudinal coordinate directed from the inlet to the outlet of a capillary. The main parameter determining the Poiseuille coefficient is the rarefaction parameter \delta=ap/(\mu v_{m}), (2) with \mu being the dynamic viscosity. Thus, large values of \delta indicate the viscous regime, while the limit \delta\to 0 corresponds to the free-molecular regime. In many application, the throughput q is used to characterize the flow rate, which is related to the mass flow rate \dot{M} as q=\frac{1}{2}v_{M}^{2}\dot{M}. (3) Consider a long capillary connecting two vacuum chambers as shown in Figure 1 . The pressure in the inlet chamber p_{in} is higher than that in the outlet chamber ( p_{in}>p_{out} ), so that the gas flows to the right according to Figure 1 . We assume that the gas flow in the capillary is stationary meaning that the mass flow rate remains constant along the capillary even though p_{in} and p_{out} vary. The assumption holds when the volumes V_{in} and V_{out} are significantly larger than the capillary volume ( V_{c}=AL ), as stated in Refs. Sha103 ; Sha99 . When the pressures p_{in} and p_{out} are known, the steady throughput is easily calculated by integrating the function G_{\mbox{\scriptsize P}}(\delta) Sha15 q=\frac{Aav_{m}}{2L}\frac{p_{in}-p_{out}}{\delta_{in}-\delta_{out}}\int_{\delta_{out}}^{\delta_{in}}G_{\mbox{\scriptsize P}}(\delta)\,\mbox{d}\delta, (4) where \delta_{in} and \delta_{out} are calculated by Eq.( 2 ) for p_{in} and p_{out} , respectively. This expression shows how the Poiseuille coefficient obtained from the linearized Boltzmann equation is applied to calculate the throughput of gases driven by a large pressure drop. Knowledge of G_{\mbox{\scriptsize P}} also allows to calculate

Read the complete text