Relativistic limits on the discretization and temporal resolution of a quantum clock
Tommaso Favalli · 2025
Read Relativistic limits on the discretization and temporal resolution of a quantum clock by Tommaso Favalli (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-05848.txt.
Introduction
Tommaso Favalli studies the limits of a quantum clock in a 2025 physics paper. The clock's time values come from a time measure paired with an energy operator whose levels are bounded and separate. Favalli asks how fine the clock's time steps can be, and when they can be treated as smooth.
With evenly spaced energy levels, the time measure can be a standard operator, and a clear limit on step size appears. In the general case, a broader kind of measure is needed. Adding more time states shrinks the smallest time step, and Favalli states when smooth treatment becomes fair. A final limit covers the clock's sharpness when it is used with light signals to measure distances in space and time.
Catalog record
| CREATOR | Tommaso Favalli |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 30 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-05848
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Relativistic limits on the discretization and temporal resolution of a quantum clock Tommaso Favalli Abstract We provide a brief discussion regarding relativistic limits on the discretization and temporal resolution of time values in a quantum clock. Our clock is characterized by a time observable chosen to be the complement of a bounded and discrete Hamiltonian which can have an equally-spaced or a generic spectrum. In the first case the time observable can be described by a Hermitian operator and we find a limit in the discretization for the time eigenvalues. Nevertheless, in both cases, the time observable can be described by a POVM and, by increasing the number of time states, we show how the bound on the minimum time quantum can be reduced and identify the conditions under which the clock values can be treated as continuous. Finally, we find a limit for temporal resolution of our time observable when the clock is used (together with light signals) in a relativistic framework for measuring spacetime distances. I Introduction It is well known that fundamental limits emerge in the precision with which to measure space and time when quantum mechanics and the theory of relativity are considered together [ 1 , 2 , 3 , 4 , 5 ] (see also [ 6 , 7 , 8 ] ). Our purpose in this work is to study the relativistic limits in the discretization and temporal resolution of time values in a quantum clock. A good definition of a clock can be found in the work by Peres [ 9 ] :<<A clock is a dynamical system which passes through a succession of states at constant time intervals>>. Our quantum clock is described by a quantum time observable chosen to be the complement of a bounded and discrete Hamiltonian which can have both an equally-spaced or a generic spectrum. Only in the case of equally-spaced energy spectrum the time observable can be described by a Hermitian operator while, in general, it will be described by a POVM. This kind of observable was introduced by Pegg in [ 10 ] (see also [ 11 , 12 , 13 , 14 , 15 ] ). It generalizes the quantum clock proposed by Salecker and Wigner (SW) in [ 16 , 17 ] , where the authors used clocks and light signals in order to measure distances between spacetime events. Pegg’s clock is, for example, widely used as a possible choice of time observable in the Page and Wootters quantum time formalism [ 18 , 19 ] (see also [ 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 ] and references therein). However, we do not adopt this framework here, and we treat our time states (to be introduced) as evolving in an external time parameter, which is standard in quantum mechanics. We will return to the connection with the Page and Wootters approach in the Conclusions. As we will see in the following, Pegg’s observable can exhibit both discrete and continuous time values, and we therefore ask whether there is a fundamental limit in the spacing between discrete time values of clock and whether time values can be safely considered as continuous . Finally, although the time values may be continuous, we ask what is the minimum resolvable interval between them when the clock operates within the relativistic SW framework, that is, what is the temporal resolution \Delta t (in what follows, we will refer to \Delta t also as temporal accuracy). Notice that throughout the text we use time values or clock values to refer to the values of the clock observable, and not to the external time parameter. We perform our investigation first considering the clock with equally-spaced energy spectrum in Section II; then we generalize the discussion for a clock with generic spectrum in Section III. We emphasize that, since any realistic quantum clock is a system with finite size, the introduction of unbounded Hamiltonians with continuous spectrum would not be possible. This is the reason why we choose to focus on bounded and discrete Hamiltonians in describing our quantum clock, also considering that this may encourage experimental applications. II Clock with equally-spaced energy spectrum II.1 The quantum clock We introduce the clock in the case of equally-spaced energy spectrum. The non-degenerate clock Hamiltonian can be written as: \hat{H}=\sum_{n=0}^{p}E_{n}\ket{E_{n}}\bra{E_{n}} (1) where E_{n}=\frac{2\pi\hslash}{T}n (2) with n=0,1,...,p and p+1=d dimension of the Hilbert space \mathcal{H} of our clock system. The meaning of T will become clear soon. Notice that we have chosen E_{0}=0 to avoid unnecessary complications. The case with E_{0}\neq 0 can be considered as a generalization, which we do not address here. Next, we introduce the time observable by defining z+1\geq p+1=d time states: \ket{\tau_{m}}=\frac{1}{\sqrt{p+1}}\sum_{n=0}^{p}e^{-i\hslash^{-1}E_{n}\tau_{m}}\ket{E_{n}} (3) where \tau_{m}=\tau_{0}+\frac{T}{z+1}m (4) with m=0,1,...,z\geq p . The states ( 3 ) exhibit a cyclic condition and the meaning of T is now clear: it represents the time taken by the clock to return to its initial state. We therefore consider three cases of interest: • for z=p we can introduce the Hermitian operator: \hat{\tau}=\sum_{m=0}^{p}\tau_{m}\ket{\tau_{m}}\bra{\tau_{m}} (5) where the time states \ket{\tau_{m}} provide an orthonormal and complete basis in \mathcal{H} . The operator ( 5 ) can be considered as conjugated (or complement) to the Hamiltonian \hat{H} : it is indeed easy to show that \hat{H} is the generator of shifts in \tau_{m} values and, viceversa, \hat{\tau} is the generator of energy shifts [ 21 ] ; • for z>p the number of time states is greater than the number of energy states and the time observable is represented by a POVM with z+1 elements \frac{p+1}{z+1}\ket{\tau_{m}}\bra{\tau_{m}} . The resolution of identity \frac{p+1}{z+1}\sum_{m=0}^{z}\ket{\tau_{m}}\bra{\tau_{m}}=\mathbb{1} is indeed still satisfied even if the time states are not orthogonal; • in the limiting case z\rightarrow\infty is possible to redefine the time states as \ket{t}=\frac{1}{\sqrt{p+1}}\sum_{n=0}^{p}e^{-i\hslash^{-1}E_{n}t}\ket{E_{n}} (6) where t is a continuous variable taking all the real values in the interval \left[t_{0},t_{0}+T\right] . The time observable is again described by a POVM generated with the operators \frac{p+1}{T}\ket{t}\bra{t}dt and the resolution of the identity reads here \frac{p+1}{T}\int dt\ket{t}\bra{t}=\mathbb{1} . In the first two cases the time values of the clock are discrete and we can search the fundamental limit in the spacing between them. We will than see that such limit reduces to zero in the case of z\rightarrow\infty , allowing us to safely consider the time values as continuous in this limiting case. Finally, we will derive a bound on the minimal resolvable interval in the clock time values. II.2 Limit in discretizing time We proceed here in our analysis by considering z\geq p and we will study z=p as a special case. From ( 2 ) and ( 4 ) we can easily calculate the spacing between two neighbors time eigenvalues: \delta\tau=\tau_{m+1}-\tau_{m}=\frac{2\pi\hslash}{\delta E\left(z+1\right)}=\frac{T}{z+1} (7) where \delta E=2\pi\hslash/T is the interval between two neighbors energy levels. We now search a lower limit for \delta\tau . The extent of the energy spectrum is \delta E\left(p+1\right) and it can be bound considering that energy cannot be arbitrarily confined in a region of space . Assuming the clock to be spherically symmetric, we thus