Read Impact Assessment of Cyberattacks in Inverter-Based Microgrids by Kerd Topallaj, Colin McKerrell, Suraj Ramanathan, Ioannis Zografopoulos (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-05592.txt.
Introduction
Kerd Topallaj and co-authors test cyberattack effects in a 2025 paper on small power grids. Modern grids add remote control to solar and other local sources, which lifts efficiency. That same remote access gives attackers entry points that could shake grid stability.
The team ran live style simulations on a changed version of a standard 39 bus test grid. The test grid held a small local grid with solar based inverters. Attacks struck the small grid at different levels of solar share, and the team watched how stability held or failed. The results help planners weigh how much remote control is safe to add.
Catalog record
| CREATOR | Kerd Topallaj, Colin McKerrell, Suraj Ramanathan, Ioannis Zografopoulos |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 29 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-05592
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Impact Assessment of Cyberattacks in Inverter-Based Microgrids Kerd Topallaj, Colin McKerrell, Suraj Ramanathan, Ioannis Zografopoulos Abstract In recent years, the evolution of modern power grids has been driven by the growing integration of remotely controlled grid assets. Although DERs ( DERs ) and IBR ( IBR ) enhance operational efficiency, they also introduce cybersecurity risks. The remote accessibility of such critical grid components creates entry points for attacks that adversaries could exploit, posing threats to the stability of the system. To evaluate the resilience of energy systems under such threats, this study employs real-time simulation and a modified version of the IEEE 39-bus system that incorporates a MG ( MG ) with solar-based IBR . The study assesses the impact of remote attacks impacting the MG stability under different levels of IBR penetrations through HIL ( HIL ) simulations. Namely, we analyze voltage, current, and frequency profiles before, during, and after cyberattack-induced disruptions. The results demonstrate that real-time HIL testing is a practical approach to uncover potential risks and develop robust mitigation strategies for resilient MG operations. AI Artificial Intelligence AGC Automatic Generation Control AMI Advanced Metering Infrastructure API Application Programming Interface ADMS Advanced Distribution Management Systems CNN Convolutional Neural Network CNT Complex Network Theory CPPS Cyber-Physical Power System CIM Common Information Model CGMES Common Grid Model Exchange Standard CPS Cyber-Physical System CHIL Controller Hardware-in-the-Loop DERs Distributed Energy Resources DoS Denial-of-Service DL Deep Learning DOE Department of Energy DT Digital Twins DSE Dynamic State Estimation DSO Distribution System Operator EMS Energy Management System ENTSO-E European Network of Transmission System Operators for Electricity EV Electric Vehicles EMT Electromagnetic Transient FACTS Flexible Alternating Current Transmission Systems FDIA False Data Injection Attack FNCS Framework for Network Co-simulation GNN Graph Neural Network GOOSE Generic Object Oriented Substation Event GFM Grid-Forming GFL Grid-Following HIL Hardware-in-the-Loop HELICS Hierarchical Engine for Large-scale Infrastructure Co-simulation HV High-Voltage HVDC High-Voltage Direct Current HPC High Performance Computing IBR Inverter-Based Resources ICT Information and Communication Technology IED Intelligent Electronic Device IoT Internet of Things IP Internet Protocol IT Information Technology ISO Independent System Operator KNN K-nearest Neighbor LFC Load Frequency Control LMP Locational Marginal Price ML Machine Learning MG Microgrid MLP Multilayer Perceptron MITM Man-in-the-Middle MDP Markov Decision Process MPS Mobile Power Resources MTD Moving Target Defenses MV/LV Medium-to-low Voltage NASPI North American Synchrophasor Initiative OSI Open Systems Interconnection OT Operational Technology PCA Principal Component Analysis PCC Point of Common Coupling PEPS Power Electronic-dominated Systems PLC Power Line Communication PMU Phasor Measurement Units PNNL Pacific Northwest National Laboratory PHIL Power Hardware-in-the-loop PSS Power System Stabilizer QoS Quality of Service RL Reinforcement Learning SCADA Supervisory Control and Data Acquisition SE State Estimation SGAM Smart Grid Architecture Model SDN Software-defined Network SSE Static State Estimation STATCOM Static Synchronous Compensator SV Sample Values SVM Support Vector Machine TF Task Force TnD Transmission and Distribution TSO Transmission System Operator t-SNE t-distributed Stochastic Neighbor Embedding VPP Virtual Power Plant WAN Wide-area Network WAMS Wide-area Measurement Systems WADC Wide-area Damping Control WAMPAC Wide-area Monitoring, Protection, and Control PV photovoltaic PCB Printed Circuit Board SCADE Supervisory Control and Data Acquisition UDP User Datagram Protocol GPIO General-Purpose Input/Output CB Circuit Breaker DER Distributed Energy Resource SO System Operators NREL National Renewable Energy Lab BESS Battery Energy Storage System UV Undervoltage MPPT Maximum Power Point Tracking I Introduction The growing penetration of DERs – such as PV ( PV ) arrays, wind turbines, and energy storage systems – requires new approaches to maintain grid reliability and stability. The MG concept has emerged as a key solution for integrating and managing both renewable and non-renewable DERs [ 1 ] . According to the NREL ( NREL ) definition, a MG is “ a group of interconnected loads and DERs that acts as a single controllable entity with respect to the grid ” [ 2 ] . Furthermore, MG s can operate in both grid-connected and islanded modes, exchanging power with the main grid or operating autonomously to support local loads. This flexibility makes MG s essential components for maintaining power system stability during grid disturbances resulting from accidental events, e.g., faults, or malicious incidents, e.g., cyberattacks. A MG ’s ability to coordinate generation and demand at the local level enhances resiliency, reduces operational costs, and can defer transmission and distribution network expansion plans. Furthermore, MG s offer SO ( SO ) the flexibility to respond to rapid fluctuations in on-site demand and supply by supporting high shares of IBR and enabling decentralized control. As the integration of DERs and MG s continues to grow, ensuring their secure and resilient operation under both normal and disruptive conditions becomes increasingly critical. One of the primary areas of interest involves assessing the performance of MG under adverse conditions, such as cyberattacks or unintentional faults, and examining their potential to trigger forced islanding events [ 3 ] . These islanding transitions sectionalize MG s from the main grid at their PCC ( PCC ), which is typically controlled by a CB ( CB ). Rapid shifts between grid-connected and islanded modes can induce transient instability, frequency deviations, and voltage fluctuations, potentially compromising system reliability [ 4 ] . Traditional testing methods focusing on offline simulations are often unable to capture real-time dynamic phenomena, while experimenting on the actual power systems or even smaller deployments is cost-prohibitive and could raise safety issues. As a result, it is essential to experiment with high-fidelity system models that respect the mission-critical and time-sensitive nature of the power system’s critical infrastructure, without impacting actual grid operations [ 5 ] . Recent advances in real-time HIL simulation offer a powerful solution to assess MG behavior before field deployment. By integrating power system models with external hardware, HIL enables realistic testing of operational stability and cyber-threats in a controlled environment, i.e., the cyber-physical testbed. Unlike purely software-based simulations, HIL provides real-time feedback by allowing interaction with physical controllers, inverters, and protection devices. Additionally, HIL methods reduce operational risks and enhance grid security by detecting vulnerabilities before real-world implementation. The contributions of this work are the following: • We combine essential power system assets and a MG into an integrated TnD ( TnD ) model. For the transmission-level system we use the IEEE 39-bus system, while the MG is comprised of a PV farm complemented by synchronous generation. • We study the impact of sophisticated cyberattacks that, after identifying an anomalous grid condition, e.g., fault, they rapidly toggle the CB at the PCC , switching the MG between islanded and grid-connected modes, and stressing the MG ’s capacity to maintain stability. • We present real-time simulation results to illustrate the impact of different IBR penetration levels on nominal operations and their potential to exacerbate grid instability. Fig. 1: System overview and attack methodology. An overview of the developed TnD system and the cyberattack kill chain is shown in Fig. 1 . The remainder of this paper is organized as follows. Section II outlines the methodology, including the MG system model and the implementation of cyberattack scenarios. Section III presents the simulation configuration and results under various attack conditions and generation mixes, analyzing their impact on system stability, frequency response, and voltage waveforms. Finally, Section IV concludes the paper and discusses directions for future