Ultrasound-Guided Robotic Blood Drawing and In Vivo Studies on Submillimetre Vessels of Rats
Shuaiqi Jing, Tianliang Yao, Ke Zhang, Di Wu, Qiulin Wang, Zixi Chen, Ke Chen, Peng Qi · 2025
Read Ultrasound-Guided Robotic Blood Drawing and In Vivo Studies on Submillimetre Vessels of Rats by Shuaiqi Jing, Tianliang Yao, Ke Zhang, Di Wu, Qiulin Wang, Zixi Chen, Ke Chen, Peng Qi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-05329.txt.
Introduction
Shuaiqi Jing and co-authors built an ultrasound-guided robot in 2025 that draws blood from vessels smaller than a millimeter in live rats. Vascular access is among the most common medical procedures, yet tiny vessels defeat human hands: adult vessels run two to three millimeters, and a child's can be under one. The system pairs a six-axis robotic arm with a three-axis end tool for fine needle control.
Multi-modal imaging and sensing give the robot its precision and safety, while ultrasound guidance is the mode evaluated in the study. Tests in live animals targeted the submillimeter vessels that make human pediatric access so hard. Readers get a robot that could spare children and the elderly repeat sticks: a needle that sees, and steadies itself, before it enters.
Catalog record
| CREATOR | Shuaiqi Jing, Tianliang Yao, Ke Zhang, Di Wu, Qiulin Wang, Zixi Chen, Ke Chen, Peng Qi |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 25 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-05329
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Ultrasound-Guided Robotic Blood Drawing and In Vivo Studies on Submillimetre Vessels of Rats Shuaiqi Jing, Tianliang Yao, Ke Zhang, Di Wu, Qiulin Wang, Zixi Chen, Ke Chen, Peng Qi Abstract Billions of vascular access procedures are performed annually worldwide, serving as a crucial first step in various clinical diagnostic and therapeutic procedures. For pediatric or elderly individuals, whose vessels are small in size (typically 2 to 3 mm in diameter for adults and < < 1 mm in children), vascular access can be highly challenging. This study presents an image-guided robotic system aimed at enhancing the accuracy of difficult vascular access procedures. The system integrates a 6-DoF (Degrees of Freedom) robotic arm with a 3-DoF end-effector, ensuring precise navigation and needle insertion. Multi-modal imaging and sensing technologies have been utilized to endow the medical robot with precision and safety, while ultrasound (US) imaging guidance is specifically evaluated in this study. To evaluate in vivo vascular access in submillimeter vessels, we conducted ultrasound-guided robotic blood drawing on the tail veins (with a diameter of 0.7 ± 0.2 mm) of 40 rats. The results demonstrate that the system achieved a first-attempt success rate of 95%. The high first-attempt success rate in intravenous vascular access, even with small blood vessels, demonstrates the system’s effectiveness in performing these procedures. This capability reduces the risk of failed attempts, minimizes patient discomfort, and enhances clinical efficiency. I Introduction Vascular access is a crucial first step in numerous medical practices, providing a fundamental prerequisite for the subsequent execution of diagnostic and therapeutic interventions [ 1 ] . It is widely utilized across various clinical contexts for blood sampling, intravenous therapy, and medication administration. Nevertheless, acquiring vascular access can be extremely challenging in difficult conditions, particularly when dealing with small and fragile veins, typically less than 1mm in diameter. This scenario is commonly encountered in pediatric patients [ 2 ] . A study involving 150 pediatric patients revealed that the first-attempt success rate for vascular access was below 50% in children aged 0-12 years [ 3 ] . These unsuccessful punctures could result in vessel damage and subsequent secondary effects, such as increased risks of further vein damage and infection. To mitigate these risks and enhance the success rate of vascular access, various imaging modalities, including near-infrared (NIR) light [ 4 ] , ultrasound (US) [ 5 , 6 ] , and visible light [ 7 ] , have been integrated to assist clinicians in precisely locating veins. NIR imaging technology is capable of producing a more distinct two-dimensional outline of blood vessels, whereas a more costly US device is able to provide additional depth information. However, clinicians are still required to personally interpret these images to obtain information crucial for guiding puncture procedures. With the recent advancements in deep learning (DL) and computer vision (CV) technologies, algorithms can now be utilized for image processing, significantly reducing the cognitive load on clinicians. Nevertheless, irrespective of whether image interpretation is manual or AI-based, the clinician still has to manually perform the puncture. Additionally, as mentioned above, some imaging systems only offer two-dimensional representations of blood vessels, lacking depth perception and potentially insufficient resolution to detect subtle vein movements, which could potentially complicate the puncture process. Furthermore, it has been suggested that the greatest challenge in venous cannulation lies not merely in the initial identification of the vein, but rather in the delicate task of accurately inserting the needle or cannula [ 8 ] . Fig. 1: Prototype of the proposed Ultrasound-guided vascular access robotic system. The system comprises a 6-DoF robotic arm integrated with a specialized mechanism for robotic vascular access, enabling precise needle manipulation under ultrasound guidance. Robotics has proven to offer advantages in medical procedures, achieving a level of precision and consistency that is comparable to, and in some cases exceeds, that of clinicians [ 9 ] . The enhanced precision of robotic systems minimizes the risk of errors and complications, potentially leading to higher success rates and better patient outcomes. These benefits render the integration of medical robotics into vascular access procedures particularly promising, as it holds the potential to significantly improve both the efficiency and reliability of this common medical practice. Several pioneering and notable research works have been reported, with commercial product developments also advancing concurrently [ 10 ] . For example, Balter and Chen et. al. devised a 7-degree-of-freedom (DOF) robotic system for executing venipuncture [ 8 ] . This system comprises a 3-DOF gantry aimed at imaging the patient’s peripheral forearm veins, coupled with a compact 4-DOF serial arm that guides the cannula into the targeted vein under closed-loop control. The robot incorporates both near-infrared and ultrasound imaging capabilities, along with an image processing unit. Nevertheless, the system’s validation was confined to a phantom arm, with cannulated vessels measuring 3.2 mm and 1.8 mm in diameter, thereby leaving its efficacy in actual clinical settings untested. Subsequently, the system underwent further development and in vivo validation on rats [ 11 ] , yielding a notable enhancement in first-attempt access rates. The robotic cannulation achieved an 87.1% success rate on the initial attempt, compared to a 58.3% success rate in the control group that relied on manual insertion. Besides, another 7-DOF trocar puncture robot was introduced to facilitate blood collection [ 12 ] . This robot boasts a position and orientation adjustment mechanism, along with an end-effector for precise needle manipulation. The development encompassed both inverse kinematics and path planning algorithms for the robot. However, the system’s validation was limited to a phantom model with a simulated vein of 4 mm in diameter, hindering its applicability in pediatric cases. Furthermore, the robot system lacks integration with any imaging modality, which further constrains its clinical validation and practicality. Additionally, these robotic systems still necessitate expertise from both medical and robotics professionals for accurate positioning and calibration. In response to the challenges mentioned above, coupled with the epidemic that has spurred the demand for more contactless and unmanned medical services [ 13 ] , intensive preliminary studies on robotic vascular access have been conducted in recent years, encompassing the authors’ prior research work in this field [ 14 , 15 , 16 ] . This paper introduces a newly upgraded robotic setup, which is potentially undergoing commercialization, as illustrated in Fig. 1 . This system employs multi-modal imaging and sensing technologies, integrated with a readily available robotic arm, to facilitate vessel access with minimal human intervention, thereby mitigating reliance on operator skill. Subsequent sections commence with a comprehensive overview of the system design, encompassing imaging/sensing modules, the needle insertion mechanism, and the control architecture. Notably, we assess the performance of the system in US-guided procedures for difficult vascular access on both phantoms and animals, underscoring its effectiveness and potential for clinical application. This evaluation highlights the system’s potential to offer a safer and more effective solution, particularly in pediatric settings. The main contributions of this paper are: • A newly designed, fully functional robotic platform to perform vascular access. • A high first-attempt success rate with precise in vivo blood draws from submillimeter vessels in rats. II System Design and Integration II-A System Overview As illustrated in Fig. 2 , the proposed Robotic Vascular Access (RVA)